Cargando…
Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging
BACKGROUND: Ultrasound imaging is used for diagnosis, treatment, and blood vessel visualization during venous catheter placement. However, various physiological factors (e.g., body temperature and exercise) influence vein diameters, which are expected to exhibit daily or diurnal fluctuations. Theref...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9719193/ https://www.ncbi.nlm.nih.gov/pubmed/36461013 http://dx.doi.org/10.1186/s12880-022-00945-9 |
_version_ | 1784843266031616000 |
---|---|
author | Miharu, Matsumoto Nobuko, Hashiguchi Hiromitsu, Kobayashi |
author_facet | Miharu, Matsumoto Nobuko, Hashiguchi Hiromitsu, Kobayashi |
author_sort | Miharu, Matsumoto |
collection | PubMed |
description | BACKGROUND: Ultrasound imaging is used for diagnosis, treatment, and blood vessel visualization during venous catheter placement. However, various physiological factors (e.g., body temperature and exercise) influence vein diameters, which are expected to exhibit daily or diurnal fluctuations. Therefore, this study aimed to determine the intraday (short-term) and interday (long-term) reproducibility of repeated measurements of the depth and diameter of peripheral superficial veins. METHODS: Twenty-three healthy young women (mean age, 21.7 ± 0.8 years) participated in the study to examine the short- and long-term reproducibility of the depth and diameter of the cutaneous vein in the left elbow fossa acquired by ultrasound imaging. Short-term measurement intervals were 10 s, and the probe was released from the skin for each acquisition, which was repeated five consecutive times. Long-term measurements were performed at the same time on the next day following the same procedure. The acquired images were analyzed for vein depth and diameter using ImageJ software. The intraclass correlation coefficient (ICC) was calculated to determine the short- and long-term reproducibility of the measurements. The relationship between the venous depth and venous diameter intra-individual variation was analyzed, as well as the influence of body composition (body fat and muscle mass) on the venous diameter and depth. RESULTS: For vein depth measurements, the short- and long-term ICCs were 0.94–0.96 and 0.88, respectively. For the vein diameter, the short- and long-term ICCs were 0.94–0.97 and 0.67, respectively. The short-term ICCs for both vein depth and diameter exceeded 0.9, indicating that the ultrasound vascular measurement was sufficiently reliable. However, long-term reproducibility was slightly lower, especially for the vein diameter. No correlation was found between the intra-individual variation of the vein diameter and vein depth. Although the vein diameter and body fat mass uncorrelated, the vein depth and body fat mass significantly correlated (r = 0.675, 95% confidence interval = 0.281–0.830). CONCLUSIONS: The long-term reproducibility of vein diameters was somewhat lower than that of the short-term reproducibility. This could be attributed to fluctuations in the physiological state of the participant rather than to the instability of the measurement. Therefore, ultrasound measurement of the peripheral superficial vein is sufficiently reliable. |
format | Online Article Text |
id | pubmed-9719193 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-97191932022-12-04 Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging Miharu, Matsumoto Nobuko, Hashiguchi Hiromitsu, Kobayashi BMC Med Imaging Research BACKGROUND: Ultrasound imaging is used for diagnosis, treatment, and blood vessel visualization during venous catheter placement. However, various physiological factors (e.g., body temperature and exercise) influence vein diameters, which are expected to exhibit daily or diurnal fluctuations. Therefore, this study aimed to determine the intraday (short-term) and interday (long-term) reproducibility of repeated measurements of the depth and diameter of peripheral superficial veins. METHODS: Twenty-three healthy young women (mean age, 21.7 ± 0.8 years) participated in the study to examine the short- and long-term reproducibility of the depth and diameter of the cutaneous vein in the left elbow fossa acquired by ultrasound imaging. Short-term measurement intervals were 10 s, and the probe was released from the skin for each acquisition, which was repeated five consecutive times. Long-term measurements were performed at the same time on the next day following the same procedure. The acquired images were analyzed for vein depth and diameter using ImageJ software. The intraclass correlation coefficient (ICC) was calculated to determine the short- and long-term reproducibility of the measurements. The relationship between the venous depth and venous diameter intra-individual variation was analyzed, as well as the influence of body composition (body fat and muscle mass) on the venous diameter and depth. RESULTS: For vein depth measurements, the short- and long-term ICCs were 0.94–0.96 and 0.88, respectively. For the vein diameter, the short- and long-term ICCs were 0.94–0.97 and 0.67, respectively. The short-term ICCs for both vein depth and diameter exceeded 0.9, indicating that the ultrasound vascular measurement was sufficiently reliable. However, long-term reproducibility was slightly lower, especially for the vein diameter. No correlation was found between the intra-individual variation of the vein diameter and vein depth. Although the vein diameter and body fat mass uncorrelated, the vein depth and body fat mass significantly correlated (r = 0.675, 95% confidence interval = 0.281–0.830). CONCLUSIONS: The long-term reproducibility of vein diameters was somewhat lower than that of the short-term reproducibility. This could be attributed to fluctuations in the physiological state of the participant rather than to the instability of the measurement. Therefore, ultrasound measurement of the peripheral superficial vein is sufficiently reliable. BioMed Central 2022-12-02 /pmc/articles/PMC9719193/ /pubmed/36461013 http://dx.doi.org/10.1186/s12880-022-00945-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Miharu, Matsumoto Nobuko, Hashiguchi Hiromitsu, Kobayashi Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
title | Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
title_full | Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
title_fullStr | Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
title_full_unstemmed | Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
title_short | Short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
title_sort | short- and long-term reproducibility of peripheral superficial vein depth and diameter measurements using ultrasound imaging |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9719193/ https://www.ncbi.nlm.nih.gov/pubmed/36461013 http://dx.doi.org/10.1186/s12880-022-00945-9 |
work_keys_str_mv | AT miharumatsumoto shortandlongtermreproducibilityofperipheralsuperficialveindepthanddiametermeasurementsusingultrasoundimaging AT nobukohashiguchi shortandlongtermreproducibilityofperipheralsuperficialveindepthanddiametermeasurementsusingultrasoundimaging AT hiromitsukobayashi shortandlongtermreproducibilityofperipheralsuperficialveindepthanddiametermeasurementsusingultrasoundimaging |