Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
BACKGROUND AND PURPOSE: The requirement of computed tomography (CT) for radiotherapy planning may be bypassed by synthetic CT (sCT) generated from magnetic resonance (MR), which has recently led to the clinical introduction of MR-only radiotherapy for specific sites. Further developments are require...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9720490/ https://www.ncbi.nlm.nih.gov/pubmed/36478992 http://dx.doi.org/10.1016/j.phro.2022.11.011 |
_version_ | 1784843567912452096 |
---|---|
author | Lapaeva, Mariia La Greca Saint-Esteven, Agustina Wallimann, Philipp Günther, Manuel Konukoglu, Ender Andratschke, Nicolaus Guckenberger, Matthias Tanadini-Lang, Stephanie Dal Bello, Riccardo |
author_facet | Lapaeva, Mariia La Greca Saint-Esteven, Agustina Wallimann, Philipp Günther, Manuel Konukoglu, Ender Andratschke, Nicolaus Guckenberger, Matthias Tanadini-Lang, Stephanie Dal Bello, Riccardo |
author_sort | Lapaeva, Mariia |
collection | PubMed |
description | BACKGROUND AND PURPOSE: The requirement of computed tomography (CT) for radiotherapy planning may be bypassed by synthetic CT (sCT) generated from magnetic resonance (MR), which has recently led to the clinical introduction of MR-only radiotherapy for specific sites. Further developments are required for abdominal sCT, mostly due to the presence of mobile air pockets affecting the dose calculation. In this study we aimed to overcome this limitation for abdominal sCT at a low field (0.35 T) hybrid MR-Linac. MATERIALS AND METHODS: A retrospective analysis was conducted enrolling 168 patients corresponding to 215 MR-CT pairs. After the exclusion criteria, 152 volumetric images were used to train the cycle-consistent generative adversarial network (CycleGAN) and 34 to test the sCT. Image similarity metrics and dose recalculation analysis were performed. RESULTS: The generated sCT faithfully reproduced the original CT and the location of the air pockets agreed with the MR scan. The dose calculation did not require manual bulk density overrides and the mean deviations of the dose-volume histogram dosimetric points were within 1 % of the CT, without any outlier above 2 %. The mean gamma passing rates were above 99 % for the 2 %/ 2 mm analysis and no cases below 95 % were observed. CONCLUSIONS: This study presented the implementation of CycleGAN to perform sCT generation in the abdominal region for a low field hybrid MR-Linac. The sCT was shown to correctly allocate the electron density for the mobile air pockets and the dosimetric analysis demonstrated the potential for future implementation of MR-only radiotherapy in the abdomen. |
format | Online Article Text |
id | pubmed-9720490 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-97204902022-12-06 Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen Lapaeva, Mariia La Greca Saint-Esteven, Agustina Wallimann, Philipp Günther, Manuel Konukoglu, Ender Andratschke, Nicolaus Guckenberger, Matthias Tanadini-Lang, Stephanie Dal Bello, Riccardo Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: The requirement of computed tomography (CT) for radiotherapy planning may be bypassed by synthetic CT (sCT) generated from magnetic resonance (MR), which has recently led to the clinical introduction of MR-only radiotherapy for specific sites. Further developments are required for abdominal sCT, mostly due to the presence of mobile air pockets affecting the dose calculation. In this study we aimed to overcome this limitation for abdominal sCT at a low field (0.35 T) hybrid MR-Linac. MATERIALS AND METHODS: A retrospective analysis was conducted enrolling 168 patients corresponding to 215 MR-CT pairs. After the exclusion criteria, 152 volumetric images were used to train the cycle-consistent generative adversarial network (CycleGAN) and 34 to test the sCT. Image similarity metrics and dose recalculation analysis were performed. RESULTS: The generated sCT faithfully reproduced the original CT and the location of the air pockets agreed with the MR scan. The dose calculation did not require manual bulk density overrides and the mean deviations of the dose-volume histogram dosimetric points were within 1 % of the CT, without any outlier above 2 %. The mean gamma passing rates were above 99 % for the 2 %/ 2 mm analysis and no cases below 95 % were observed. CONCLUSIONS: This study presented the implementation of CycleGAN to perform sCT generation in the abdominal region for a low field hybrid MR-Linac. The sCT was shown to correctly allocate the electron density for the mobile air pockets and the dosimetric analysis demonstrated the potential for future implementation of MR-only radiotherapy in the abdomen. Elsevier 2022-11-28 /pmc/articles/PMC9720490/ /pubmed/36478992 http://dx.doi.org/10.1016/j.phro.2022.11.011 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Research Article Lapaeva, Mariia La Greca Saint-Esteven, Agustina Wallimann, Philipp Günther, Manuel Konukoglu, Ender Andratschke, Nicolaus Guckenberger, Matthias Tanadini-Lang, Stephanie Dal Bello, Riccardo Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
title | Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
title_full | Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
title_fullStr | Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
title_full_unstemmed | Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
title_short | Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
title_sort | synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9720490/ https://www.ncbi.nlm.nih.gov/pubmed/36478992 http://dx.doi.org/10.1016/j.phro.2022.11.011 |
work_keys_str_mv | AT lapaevamariia syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT lagrecasaintestevenagustina syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT wallimannphilipp syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT gunthermanuel syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT konukogluender syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT andratschkenicolaus syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT guckenbergermatthias syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT tanadinilangstephanie syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen AT dalbelloriccardo syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen |