Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen

BACKGROUND AND PURPOSE: The requirement of computed tomography (CT) for radiotherapy planning may be bypassed by synthetic CT (sCT) generated from magnetic resonance (MR), which has recently led to the clinical introduction of MR-only radiotherapy for specific sites. Further developments are require...

Descripción completa

Detalles Bibliográficos
Autores principales: Lapaeva, Mariia, La Greca Saint-Esteven, Agustina, Wallimann, Philipp, Günther, Manuel, Konukoglu, Ender, Andratschke, Nicolaus, Guckenberger, Matthias, Tanadini-Lang, Stephanie, Dal Bello, Riccardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9720490/
https://www.ncbi.nlm.nih.gov/pubmed/36478992
http://dx.doi.org/10.1016/j.phro.2022.11.011
_version_ 1784843567912452096
author Lapaeva, Mariia
La Greca Saint-Esteven, Agustina
Wallimann, Philipp
Günther, Manuel
Konukoglu, Ender
Andratschke, Nicolaus
Guckenberger, Matthias
Tanadini-Lang, Stephanie
Dal Bello, Riccardo
author_facet Lapaeva, Mariia
La Greca Saint-Esteven, Agustina
Wallimann, Philipp
Günther, Manuel
Konukoglu, Ender
Andratschke, Nicolaus
Guckenberger, Matthias
Tanadini-Lang, Stephanie
Dal Bello, Riccardo
author_sort Lapaeva, Mariia
collection PubMed
description BACKGROUND AND PURPOSE: The requirement of computed tomography (CT) for radiotherapy planning may be bypassed by synthetic CT (sCT) generated from magnetic resonance (MR), which has recently led to the clinical introduction of MR-only radiotherapy for specific sites. Further developments are required for abdominal sCT, mostly due to the presence of mobile air pockets affecting the dose calculation. In this study we aimed to overcome this limitation for abdominal sCT at a low field (0.35 T) hybrid MR-Linac. MATERIALS AND METHODS: A retrospective analysis was conducted enrolling 168 patients corresponding to 215 MR-CT pairs. After the exclusion criteria, 152 volumetric images were used to train the cycle-consistent generative adversarial network (CycleGAN) and 34 to test the sCT. Image similarity metrics and dose recalculation analysis were performed. RESULTS: The generated sCT faithfully reproduced the original CT and the location of the air pockets agreed with the MR scan. The dose calculation did not require manual bulk density overrides and the mean deviations of the dose-volume histogram dosimetric points were within 1 % of the CT, without any outlier above 2 %. The mean gamma passing rates were above 99 % for the 2 %/ 2 mm analysis and no cases below 95 % were observed. CONCLUSIONS: This study presented the implementation of CycleGAN to perform sCT generation in the abdominal region for a low field hybrid MR-Linac. The sCT was shown to correctly allocate the electron density for the mobile air pockets and the dosimetric analysis demonstrated the potential for future implementation of MR-only radiotherapy in the abdomen.
format Online
Article
Text
id pubmed-9720490
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97204902022-12-06 Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen Lapaeva, Mariia La Greca Saint-Esteven, Agustina Wallimann, Philipp Günther, Manuel Konukoglu, Ender Andratschke, Nicolaus Guckenberger, Matthias Tanadini-Lang, Stephanie Dal Bello, Riccardo Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: The requirement of computed tomography (CT) for radiotherapy planning may be bypassed by synthetic CT (sCT) generated from magnetic resonance (MR), which has recently led to the clinical introduction of MR-only radiotherapy for specific sites. Further developments are required for abdominal sCT, mostly due to the presence of mobile air pockets affecting the dose calculation. In this study we aimed to overcome this limitation for abdominal sCT at a low field (0.35 T) hybrid MR-Linac. MATERIALS AND METHODS: A retrospective analysis was conducted enrolling 168 patients corresponding to 215 MR-CT pairs. After the exclusion criteria, 152 volumetric images were used to train the cycle-consistent generative adversarial network (CycleGAN) and 34 to test the sCT. Image similarity metrics and dose recalculation analysis were performed. RESULTS: The generated sCT faithfully reproduced the original CT and the location of the air pockets agreed with the MR scan. The dose calculation did not require manual bulk density overrides and the mean deviations of the dose-volume histogram dosimetric points were within 1 % of the CT, without any outlier above 2 %. The mean gamma passing rates were above 99 % for the 2 %/ 2 mm analysis and no cases below 95 % were observed. CONCLUSIONS: This study presented the implementation of CycleGAN to perform sCT generation in the abdominal region for a low field hybrid MR-Linac. The sCT was shown to correctly allocate the electron density for the mobile air pockets and the dosimetric analysis demonstrated the potential for future implementation of MR-only radiotherapy in the abdomen. Elsevier 2022-11-28 /pmc/articles/PMC9720490/ /pubmed/36478992 http://dx.doi.org/10.1016/j.phro.2022.11.011 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Research Article
Lapaeva, Mariia
La Greca Saint-Esteven, Agustina
Wallimann, Philipp
Günther, Manuel
Konukoglu, Ender
Andratschke, Nicolaus
Guckenberger, Matthias
Tanadini-Lang, Stephanie
Dal Bello, Riccardo
Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
title Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
title_full Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
title_fullStr Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
title_full_unstemmed Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
title_short Synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
title_sort synthetic computed tomography for low-field magnetic resonance-guided radiotherapy in the abdomen
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9720490/
https://www.ncbi.nlm.nih.gov/pubmed/36478992
http://dx.doi.org/10.1016/j.phro.2022.11.011
work_keys_str_mv AT lapaevamariia syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT lagrecasaintestevenagustina syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT wallimannphilipp syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT gunthermanuel syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT konukogluender syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT andratschkenicolaus syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT guckenbergermatthias syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT tanadinilangstephanie syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen
AT dalbelloriccardo syntheticcomputedtomographyforlowfieldmagneticresonanceguidedradiotherapyintheabdomen