Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II

OBJECTIVES: The impacts of ventilation tube (VT) type and effusion composition on the VT extrusion rate and complications in children with otitis media remain unclear. This part II study evaluated the factors affecting the extrusion rate, recurrence rate, and complications of VT insertion. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoo, Myung Hoon, Cho, Yang-Sun, Choi, June, Choung, Yun Hoon, Chung, Jae-Ho, Chung, Jong Woo, Han, Gyu Cheol, Jun, Beom Cho, Kim, Dong-Kee, Kim, Kyu Sung, Lee, Jun Ho, Lee, Kyu-Yup, Lee, Seung Hwan, Moon, In Seok, Park, Hong Ju, Park, Shi Nae, Rhee, Jihye, Seo, Jae Hyun, Yeo, Seung Geun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Otorhinolaryngology-Head and Neck Surgery 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9723292/
https://www.ncbi.nlm.nih.gov/pubmed/36097840
http://dx.doi.org/10.21053/ceo.2022.00934
_version_ 1784844138645028864
author Yoo, Myung Hoon
Cho, Yang-Sun
Choi, June
Choung, Yun Hoon
Chung, Jae-Ho
Chung, Jong Woo
Han, Gyu Cheol
Jun, Beom Cho
Kim, Dong-Kee
Kim, Kyu Sung
Lee, Jun Ho
Lee, Kyu-Yup
Lee, Seung Hwan
Moon, In Seok
Park, Hong Ju
Park, Shi Nae
Rhee, Jihye
Seo, Jae Hyun
Yeo, Seung Geun
author_facet Yoo, Myung Hoon
Cho, Yang-Sun
Choi, June
Choung, Yun Hoon
Chung, Jae-Ho
Chung, Jong Woo
Han, Gyu Cheol
Jun, Beom Cho
Kim, Dong-Kee
Kim, Kyu Sung
Lee, Jun Ho
Lee, Kyu-Yup
Lee, Seung Hwan
Moon, In Seok
Park, Hong Ju
Park, Shi Nae
Rhee, Jihye
Seo, Jae Hyun
Yeo, Seung Geun
author_sort Yoo, Myung Hoon
collection PubMed
description OBJECTIVES: The impacts of ventilation tube (VT) type and effusion composition on the VT extrusion rate and complications in children with otitis media remain unclear. This part II study evaluated the factors affecting the extrusion rate, recurrence rate, and complications of VT insertion. METHODS: A prospective study was conducted between June 2014 and December 2016 (the EVENT study [analysis of the effectiveness of ventilation tube insertion in pediatric patients with chronic otitis media]), with follow-up data collected until the end of 2017. Patients aged <15 years diagnosed with otitis media with effusion who received VT insertion were recruited at 15 tertiary hospitals. The primary outcomes were time to extrusion of VT, time to effusion recurrence, and complications. RESULTS: Data from 401 patients were analyzed. After excluding the results of long-lasting tubes (Paparella type II and T-tubes), silicone tubes (Paparella type I) exhibited a significantly longer extended time to extrusion (mean, 400 days) than titanium tubes (collar-button-type 1.0 mm: mean, 312 days; P<0.001). VT material (hazard ratio [HR], 2.117, 95% confidence interval [CI], 1.254–3.572; P=0.005), age (HR, 3.949; 95% CI, 1.239–12.590; P=0.02), and effusion composition (P=0.005) were significantly associated with the time to recurrence of middle ear effusion. Ears with purulent (mean, 567 days) and glue-like (mean, 588 days) effusions exhibited a shorter time to recurrence than ears with serous (mean, 846 days) or mucoid (mean, 925 days) effusions. The revision VT rates during follow-up were 3.5%, 15.5%, 10.4%, and 38.9% in ears with serous, mucoid, glue-like, and purulent effusions, respectively (P<0.001). The revision surgery rates were higher among patients aged <7 years than among those aged ≥7 years. CONCLUSION: Silicone tubes (Paparella type I) were less prone to early extrusion than titanium 1.0 mm tubes. VT type, patient age, and effusion composition affected the time to recurrence of effusion.
format Online
Article
Text
id pubmed-9723292
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Society of Otorhinolaryngology-Head and Neck Surgery
record_format MEDLINE/PubMed
spelling pubmed-97232922022-12-15 Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II Yoo, Myung Hoon Cho, Yang-Sun Choi, June Choung, Yun Hoon Chung, Jae-Ho Chung, Jong Woo Han, Gyu Cheol Jun, Beom Cho Kim, Dong-Kee Kim, Kyu Sung Lee, Jun Ho Lee, Kyu-Yup Lee, Seung Hwan Moon, In Seok Park, Hong Ju Park, Shi Nae Rhee, Jihye Seo, Jae Hyun Yeo, Seung Geun Clin Exp Otorhinolaryngol Original Article OBJECTIVES: The impacts of ventilation tube (VT) type and effusion composition on the VT extrusion rate and complications in children with otitis media remain unclear. This part II study evaluated the factors affecting the extrusion rate, recurrence rate, and complications of VT insertion. METHODS: A prospective study was conducted between June 2014 and December 2016 (the EVENT study [analysis of the effectiveness of ventilation tube insertion in pediatric patients with chronic otitis media]), with follow-up data collected until the end of 2017. Patients aged <15 years diagnosed with otitis media with effusion who received VT insertion were recruited at 15 tertiary hospitals. The primary outcomes were time to extrusion of VT, time to effusion recurrence, and complications. RESULTS: Data from 401 patients were analyzed. After excluding the results of long-lasting tubes (Paparella type II and T-tubes), silicone tubes (Paparella type I) exhibited a significantly longer extended time to extrusion (mean, 400 days) than titanium tubes (collar-button-type 1.0 mm: mean, 312 days; P<0.001). VT material (hazard ratio [HR], 2.117, 95% confidence interval [CI], 1.254–3.572; P=0.005), age (HR, 3.949; 95% CI, 1.239–12.590; P=0.02), and effusion composition (P=0.005) were significantly associated with the time to recurrence of middle ear effusion. Ears with purulent (mean, 567 days) and glue-like (mean, 588 days) effusions exhibited a shorter time to recurrence than ears with serous (mean, 846 days) or mucoid (mean, 925 days) effusions. The revision VT rates during follow-up were 3.5%, 15.5%, 10.4%, and 38.9% in ears with serous, mucoid, glue-like, and purulent effusions, respectively (P<0.001). The revision surgery rates were higher among patients aged <7 years than among those aged ≥7 years. CONCLUSION: Silicone tubes (Paparella type I) were less prone to early extrusion than titanium 1.0 mm tubes. VT type, patient age, and effusion composition affected the time to recurrence of effusion. Korean Society of Otorhinolaryngology-Head and Neck Surgery 2022-11 2022-09-01 /pmc/articles/PMC9723292/ /pubmed/36097840 http://dx.doi.org/10.21053/ceo.2022.00934 Text en Copyright © 2022 by Korean Society of Otorhinolaryngology-Head and Neck Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yoo, Myung Hoon
Cho, Yang-Sun
Choi, June
Choung, Yun Hoon
Chung, Jae-Ho
Chung, Jong Woo
Han, Gyu Cheol
Jun, Beom Cho
Kim, Dong-Kee
Kim, Kyu Sung
Lee, Jun Ho
Lee, Kyu-Yup
Lee, Seung Hwan
Moon, In Seok
Park, Hong Ju
Park, Shi Nae
Rhee, Jihye
Seo, Jae Hyun
Yeo, Seung Geun
Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II
title Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II
title_full Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II
title_fullStr Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II
title_full_unstemmed Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II
title_short Factors Affecting the Extrusion Rate and Complications After Ventilation Tube Insertion: A Multicenter Registry Study on the Effectiveness of Ventilation Tube Insertion in Pediatric Patients With Chronic Otitis Media With Effusion—Part II
title_sort factors affecting the extrusion rate and complications after ventilation tube insertion: a multicenter registry study on the effectiveness of ventilation tube insertion in pediatric patients with chronic otitis media with effusion—part ii
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9723292/
https://www.ncbi.nlm.nih.gov/pubmed/36097840
http://dx.doi.org/10.21053/ceo.2022.00934
work_keys_str_mv AT yoomyunghoon factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT choyangsun factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT choijune factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT choungyunhoon factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT chungjaeho factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT chungjongwoo factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT hangyucheol factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT junbeomcho factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT kimdongkee factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT kimkyusung factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT leejunho factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT leekyuyup factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT leeseunghwan factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT mooninseok factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT parkhongju factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT parkshinae factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT rheejihye factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT seojaehyun factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii
AT yeoseunggeun factorsaffectingtheextrusionrateandcomplicationsafterventilationtubeinsertionamulticenterregistrystudyontheeffectivenessofventilationtubeinsertioninpediatricpatientswithchronicotitismediawitheffusionpartii