Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins

PURPOSE: This study aimed to analyze the effect of body mass factors (BMFs) on setup errors in gynecologic tumors, and whether the planned tumor volumes (PTVs) are adequate for obese patients. METHODS: This was a retrospective study of 46 consecutive female patients with gynecologic tumors who were...

Descripción completa

Detalles Bibliográficos
Autores principales: Mulla, Zaheeda, Hashem, Rania, AlMohamad, Abdullah, Weber, Amina, Habibullah, Hanadi, Abdulmoula, Ghassan, Mohiuddin, Mohamed G., Ujaimi, Reem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9723305/
https://www.ncbi.nlm.nih.gov/pubmed/36483065
http://dx.doi.org/10.1016/j.adro.2022.101108
_version_ 1784844142107426816
author Mulla, Zaheeda
Hashem, Rania
AlMohamad, Abdullah
Weber, Amina
Habibullah, Hanadi
Abdulmoula, Ghassan
Mohiuddin, Mohamed G.
Ujaimi, Reem
author_facet Mulla, Zaheeda
Hashem, Rania
AlMohamad, Abdullah
Weber, Amina
Habibullah, Hanadi
Abdulmoula, Ghassan
Mohiuddin, Mohamed G.
Ujaimi, Reem
author_sort Mulla, Zaheeda
collection PubMed
description PURPOSE: This study aimed to analyze the effect of body mass factors (BMFs) on setup errors in gynecologic tumors, and whether the planned tumor volumes (PTVs) are adequate for obese patients. METHODS: This was a retrospective study of 46 consecutive female patients with gynecologic tumors who were treated with volumetric modulated arc therapy. Setup accuracy was verified using daily cone beam computed tomography. Accuracy was determined for each fraction by testing 2 different PTVs (cutoff I = ≤0.7 cm; cutoff II = ≤1.0 cm). A pooled analysis was conducted to test the association between accuracy levels (within vs beyond PTV) and the mean and variance of body mass index (BMI), umbilical (UC), and hip circumference (HC). A receiver operating characteristics curve analysis was carried out to test the sensitivity of BMI, UC, and HC in predicting inaccurate setup. RESULTS: A significant association between BMFs and level of accuracy was observed in the lateral and vertical directions, but not in the longitudinal direction. In the lateral direction, inaccurate setups were associated with a greater BMI (mean difference: ∼3.50 kg/m(2); P = .001), UC (∼10 cm), and HC (∼8 cm) compared with accurate setups (P < .001). With respect to the vertical direction, inaccurate setups (>0.7 cm margin [cutoff I]) were associated with a greater BMI (mean difference = 7.4 kg/m(2); P = .001), UC (5.3 cm; P < .001), and HC (16.0 cm; P < .001) with reference to accurate setups. The receiver operating characteristics curve analysis showed that a BMI >31.4 kg/m(2) was predictive for inaccurate setup in the vertical direction with 90.0% sensitivity with respect to cutoff I. Furthermore, a BMI >30.3 kg/m(2) was predictive for inaccurate setup in the lateral direction with 92.5% sensitivity with respect to cutoff II. CONCLUSIONS: The accuracy of radiation therapy setups for gynecologic tumors is highly sensitive to patients’ BMI, notably in the lateral and vertical directions. We suggest that daily cone beam computed tomography should be applied on patients with a BMI >30.3 kg/m(2), using customized protocols that are lower in dose and comparable in image quality.
format Online
Article
Text
id pubmed-9723305
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97233052022-12-07 Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins Mulla, Zaheeda Hashem, Rania AlMohamad, Abdullah Weber, Amina Habibullah, Hanadi Abdulmoula, Ghassan Mohiuddin, Mohamed G. Ujaimi, Reem Adv Radiat Oncol Scientific Article PURPOSE: This study aimed to analyze the effect of body mass factors (BMFs) on setup errors in gynecologic tumors, and whether the planned tumor volumes (PTVs) are adequate for obese patients. METHODS: This was a retrospective study of 46 consecutive female patients with gynecologic tumors who were treated with volumetric modulated arc therapy. Setup accuracy was verified using daily cone beam computed tomography. Accuracy was determined for each fraction by testing 2 different PTVs (cutoff I = ≤0.7 cm; cutoff II = ≤1.0 cm). A pooled analysis was conducted to test the association between accuracy levels (within vs beyond PTV) and the mean and variance of body mass index (BMI), umbilical (UC), and hip circumference (HC). A receiver operating characteristics curve analysis was carried out to test the sensitivity of BMI, UC, and HC in predicting inaccurate setup. RESULTS: A significant association between BMFs and level of accuracy was observed in the lateral and vertical directions, but not in the longitudinal direction. In the lateral direction, inaccurate setups were associated with a greater BMI (mean difference: ∼3.50 kg/m(2); P = .001), UC (∼10 cm), and HC (∼8 cm) compared with accurate setups (P < .001). With respect to the vertical direction, inaccurate setups (>0.7 cm margin [cutoff I]) were associated with a greater BMI (mean difference = 7.4 kg/m(2); P = .001), UC (5.3 cm; P < .001), and HC (16.0 cm; P < .001) with reference to accurate setups. The receiver operating characteristics curve analysis showed that a BMI >31.4 kg/m(2) was predictive for inaccurate setup in the vertical direction with 90.0% sensitivity with respect to cutoff I. Furthermore, a BMI >30.3 kg/m(2) was predictive for inaccurate setup in the lateral direction with 92.5% sensitivity with respect to cutoff II. CONCLUSIONS: The accuracy of radiation therapy setups for gynecologic tumors is highly sensitive to patients’ BMI, notably in the lateral and vertical directions. We suggest that daily cone beam computed tomography should be applied on patients with a BMI >30.3 kg/m(2), using customized protocols that are lower in dose and comparable in image quality. Elsevier 2022-10-25 /pmc/articles/PMC9723305/ /pubmed/36483065 http://dx.doi.org/10.1016/j.adro.2022.101108 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Scientific Article
Mulla, Zaheeda
Hashem, Rania
AlMohamad, Abdullah
Weber, Amina
Habibullah, Hanadi
Abdulmoula, Ghassan
Mohiuddin, Mohamed G.
Ujaimi, Reem
Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins
title Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins
title_full Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins
title_fullStr Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins
title_full_unstemmed Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins
title_short Effect of Body Mass Factors on Setup Displacement in Gynecologic Tumors and Subsequent Effect on PTV Margins
title_sort effect of body mass factors on setup displacement in gynecologic tumors and subsequent effect on ptv margins
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9723305/
https://www.ncbi.nlm.nih.gov/pubmed/36483065
http://dx.doi.org/10.1016/j.adro.2022.101108
work_keys_str_mv AT mullazaheeda effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT hashemrania effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT almohamadabdullah effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT weberamina effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT habibullahhanadi effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT abdulmoulaghassan effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT mohiuddinmohamedg effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins
AT ujaimireem effectofbodymassfactorsonsetupdisplacementingynecologictumorsandsubsequenteffectonptvmargins