Cargando…

Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System

BACKGROUND: Seroma remains a leading postsurgical complication in plastic surgery. Conventional drains are ineffective in clearing blood and fluid and closing down surgical spaces. The Interi (Internal Closure System, IC Surgical, Grand Rapids, MI) is comprised of a novel branching internal manifold...

Descripción completa

Detalles Bibliográficos
Autores principales: Alfonso, David, Bengtson, Bradley, McGuire, Patricia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9724786/
https://www.ncbi.nlm.nih.gov/pubmed/36483850
http://dx.doi.org/10.1093/asjof/ojac073
_version_ 1784844490176987136
author Alfonso, David
Bengtson, Bradley
McGuire, Patricia
author_facet Alfonso, David
Bengtson, Bradley
McGuire, Patricia
author_sort Alfonso, David
collection PubMed
description BACKGROUND: Seroma remains a leading postsurgical complication in plastic surgery. Conventional drains are ineffective in clearing blood and fluid and closing down surgical spaces. The Interi (Internal Closure System, IC Surgical, Grand Rapids, MI) is comprised of a novel branching internal manifold attached to a self-contained portable pump with a higher, consistent, continuous negative pressure, may reduce this long-standing issue. In addition, high-resolution ultrasound (HRUS) has emerged as an ideal tool to visualize structures, fluid collections, and seromas internally. OBJECTIVES: This study evaluates Interi in full abdominoplasty patients utilizing HRUS to evaluate Interi's ability to evacuate blood and fluid, hold internal tissues together and document, for the first time, what internal tissue healing actually looks like radiographically. METHODS: An IRB approved, Contract Research Organization reviewed retrospective study evaluated consecutive patients undergoing full abdominoplasty utilizing Interi from July 2020 through March 2021 by three plastic surgeons. HRUS visualized and confirmed the presence or absence of fluid collections and healing tissue planes during the postoperative process. Study data and all adverse events were recorded, with HRUS images reviewed by investigators and confirmed by an independent radiologist. RESULTS: Seventy-one Interi patients were enrolled. Mean age was 43 (range: 21-74) and BMI was 28. Seroma was confirmed clinically and through HRUS in 3/71 patients, and was associated with either clot (2) or failure to activate system (1). Interi's ability to eliminate fluid and approximate/hold surgical tissue planes together was confirmed with HRUS. No other major complications, including abscess, hematomas, or flap necrosis were observed. CONCLUSIONS: This novel Internal Tissue Closure System effectively evacuated blood and fluid, approximated and maintained closure of internal tissue planes in abdominoplasty patients, allowing for primary tissue healing and internal wound closure to occur. Healing tissue planes and any fluid present are easily identified on HRUS visualizing actual internal tissue healing with a simple, widely available radiographic scan. LEVEL OF EVIDENCE: 3: [Image: see text]
format Online
Article
Text
id pubmed-9724786
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-97247862022-12-07 Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System Alfonso, David Bengtson, Bradley McGuire, Patricia Aesthet Surg J Open Forum Body Contouring BACKGROUND: Seroma remains a leading postsurgical complication in plastic surgery. Conventional drains are ineffective in clearing blood and fluid and closing down surgical spaces. The Interi (Internal Closure System, IC Surgical, Grand Rapids, MI) is comprised of a novel branching internal manifold attached to a self-contained portable pump with a higher, consistent, continuous negative pressure, may reduce this long-standing issue. In addition, high-resolution ultrasound (HRUS) has emerged as an ideal tool to visualize structures, fluid collections, and seromas internally. OBJECTIVES: This study evaluates Interi in full abdominoplasty patients utilizing HRUS to evaluate Interi's ability to evacuate blood and fluid, hold internal tissues together and document, for the first time, what internal tissue healing actually looks like radiographically. METHODS: An IRB approved, Contract Research Organization reviewed retrospective study evaluated consecutive patients undergoing full abdominoplasty utilizing Interi from July 2020 through March 2021 by three plastic surgeons. HRUS visualized and confirmed the presence or absence of fluid collections and healing tissue planes during the postoperative process. Study data and all adverse events were recorded, with HRUS images reviewed by investigators and confirmed by an independent radiologist. RESULTS: Seventy-one Interi patients were enrolled. Mean age was 43 (range: 21-74) and BMI was 28. Seroma was confirmed clinically and through HRUS in 3/71 patients, and was associated with either clot (2) or failure to activate system (1). Interi's ability to eliminate fluid and approximate/hold surgical tissue planes together was confirmed with HRUS. No other major complications, including abscess, hematomas, or flap necrosis were observed. CONCLUSIONS: This novel Internal Tissue Closure System effectively evacuated blood and fluid, approximated and maintained closure of internal tissue planes in abdominoplasty patients, allowing for primary tissue healing and internal wound closure to occur. Healing tissue planes and any fluid present are easily identified on HRUS visualizing actual internal tissue healing with a simple, widely available radiographic scan. LEVEL OF EVIDENCE: 3: [Image: see text] Oxford University Press 2022-09-20 /pmc/articles/PMC9724786/ /pubmed/36483850 http://dx.doi.org/10.1093/asjof/ojac073 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of The Aesthetic Society. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Body Contouring
Alfonso, David
Bengtson, Bradley
McGuire, Patricia
Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System
title Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System
title_full Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System
title_fullStr Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System
title_full_unstemmed Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System
title_short Defining Internal Tissue Closure: High-Resolution Ultrasound Evaluation of Interi—A Novel Internal Tissue Closure System
title_sort defining internal tissue closure: high-resolution ultrasound evaluation of interi—a novel internal tissue closure system
topic Body Contouring
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9724786/
https://www.ncbi.nlm.nih.gov/pubmed/36483850
http://dx.doi.org/10.1093/asjof/ojac073
work_keys_str_mv AT alfonsodavid defininginternaltissueclosurehighresolutionultrasoundevaluationofinterianovelinternaltissueclosuresystem
AT bengtsonbradley defininginternaltissueclosurehighresolutionultrasoundevaluationofinterianovelinternaltissueclosuresystem
AT mcguirepatricia defininginternaltissueclosurehighresolutionultrasoundevaluationofinterianovelinternaltissueclosuresystem