Cargando…

Reliability of electroencephalogram indicator and event related potential in subacute stroke

Cognitive impairment is observed in 12% to 56% of stroke patients, and screening for cognitive impairment is often complex and time-consuming, with results dependent on patient compliance. Therefore, there is a need for an objective method to assess cognitive impairment regardless of patient complia...

Descripción completa

Detalles Bibliográficos
Autores principales: Yun, Dong Hyuk, Sohn, Min Kyun, Choi, Jae Eun, Jee, Sungju
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9726396/
https://www.ncbi.nlm.nih.gov/pubmed/36482615
http://dx.doi.org/10.1097/MD.0000000000031766
_version_ 1784844771534045184
author Yun, Dong Hyuk
Sohn, Min Kyun
Choi, Jae Eun
Jee, Sungju
author_facet Yun, Dong Hyuk
Sohn, Min Kyun
Choi, Jae Eun
Jee, Sungju
author_sort Yun, Dong Hyuk
collection PubMed
description Cognitive impairment is observed in 12% to 56% of stroke patients, and screening for cognitive impairment is often complex and time-consuming, with results dependent on patient compliance. Therefore, there is a need for an objective method to assess cognitive impairment regardless of patient compliance. Objective evaluation methods include electroencephalogram (EEG) and event-related potential (ERP). This study was conducted to assess intra-tester reliability of resting EEG-based spectral features and auditory/visual P300 latency/amplitude in patients with subacute ischemic stroke. Twenty patients with subacute ischemic stroke were included in the study. The resting EEG and P300 wave using an auditory and visual oddball paradigm were measured at baseline and once again in 24 hours. The following electrode positions (10–20 system) were constantly recorded: F3 (Frontal), Fz, F4, C3 (Central), Cz, C4, P3 (Parietal), Pz, P4. DAR (delta/alpha ratio) and BSI (brain symmetry index) were determined using EEG data. F3 and F4, C3 and C4 and P3 and P4 were switched according to the stroke side and classified as affected hemisphere (AH) and unaffected hemisphere (UH) after the evaluation. In ERP, the amplitude and latency of P300 were obtained. In reliability analysis of EEG-based spectral characteristics, significant reliability was observed for DAR (ICC = 0.447), BSldir (ICC = 0.713) and BSIdir(theta) (ICC = 0.724) (Table 4). DAR was showed a poor ICC level, and BSIdir and BSIdir(theta) had a moderate ICC level. Visual P300 latency showed excellent intraclass correlation coefficient (ICC) in several montages (P(UH) = 0.972, Pz = 0.945). In 6 montages, auditory P300 latency was reliable, while in 9 montages, visual P300 latency was reliable. In 4 montages, auditory P300 amplitude was reliable, while visual P300 amplitude was reliable in 7. The visual P300 was more reliable than the auditory P300. The ICC values for P300 latency were greater than those for amplitude. Therefore, when ERP is performed on subacute stroke patients, visual has higher reliability than auditory.
format Online
Article
Text
id pubmed-9726396
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-97263962022-12-09 Reliability of electroencephalogram indicator and event related potential in subacute stroke Yun, Dong Hyuk Sohn, Min Kyun Choi, Jae Eun Jee, Sungju Medicine (Baltimore) 5300 Cognitive impairment is observed in 12% to 56% of stroke patients, and screening for cognitive impairment is often complex and time-consuming, with results dependent on patient compliance. Therefore, there is a need for an objective method to assess cognitive impairment regardless of patient compliance. Objective evaluation methods include electroencephalogram (EEG) and event-related potential (ERP). This study was conducted to assess intra-tester reliability of resting EEG-based spectral features and auditory/visual P300 latency/amplitude in patients with subacute ischemic stroke. Twenty patients with subacute ischemic stroke were included in the study. The resting EEG and P300 wave using an auditory and visual oddball paradigm were measured at baseline and once again in 24 hours. The following electrode positions (10–20 system) were constantly recorded: F3 (Frontal), Fz, F4, C3 (Central), Cz, C4, P3 (Parietal), Pz, P4. DAR (delta/alpha ratio) and BSI (brain symmetry index) were determined using EEG data. F3 and F4, C3 and C4 and P3 and P4 were switched according to the stroke side and classified as affected hemisphere (AH) and unaffected hemisphere (UH) after the evaluation. In ERP, the amplitude and latency of P300 were obtained. In reliability analysis of EEG-based spectral characteristics, significant reliability was observed for DAR (ICC = 0.447), BSldir (ICC = 0.713) and BSIdir(theta) (ICC = 0.724) (Table 4). DAR was showed a poor ICC level, and BSIdir and BSIdir(theta) had a moderate ICC level. Visual P300 latency showed excellent intraclass correlation coefficient (ICC) in several montages (P(UH) = 0.972, Pz = 0.945). In 6 montages, auditory P300 latency was reliable, while in 9 montages, visual P300 latency was reliable. In 4 montages, auditory P300 amplitude was reliable, while visual P300 amplitude was reliable in 7. The visual P300 was more reliable than the auditory P300. The ICC values for P300 latency were greater than those for amplitude. Therefore, when ERP is performed on subacute stroke patients, visual has higher reliability than auditory. Lippincott Williams & Wilkins 2022-12-02 /pmc/articles/PMC9726396/ /pubmed/36482615 http://dx.doi.org/10.1097/MD.0000000000031766 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC) (https://creativecommons.org/licenses/by-nc/4.0/) , where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal.
spellingShingle 5300
Yun, Dong Hyuk
Sohn, Min Kyun
Choi, Jae Eun
Jee, Sungju
Reliability of electroencephalogram indicator and event related potential in subacute stroke
title Reliability of electroencephalogram indicator and event related potential in subacute stroke
title_full Reliability of electroencephalogram indicator and event related potential in subacute stroke
title_fullStr Reliability of electroencephalogram indicator and event related potential in subacute stroke
title_full_unstemmed Reliability of electroencephalogram indicator and event related potential in subacute stroke
title_short Reliability of electroencephalogram indicator and event related potential in subacute stroke
title_sort reliability of electroencephalogram indicator and event related potential in subacute stroke
topic 5300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9726396/
https://www.ncbi.nlm.nih.gov/pubmed/36482615
http://dx.doi.org/10.1097/MD.0000000000031766
work_keys_str_mv AT yundonghyuk reliabilityofelectroencephalogramindicatorandeventrelatedpotentialinsubacutestroke
AT sohnminkyun reliabilityofelectroencephalogramindicatorandeventrelatedpotentialinsubacutestroke
AT choijaeeun reliabilityofelectroencephalogramindicatorandeventrelatedpotentialinsubacutestroke
AT jeesungju reliabilityofelectroencephalogramindicatorandeventrelatedpotentialinsubacutestroke