An estimated gland volume of > 60 cc is a relative contraindication to brachytherapy for prostate cancer. As volume estimation using biopsy ultrasound (Bx-US) alone may be inaccurate, many centers perform additional volume assessments prior to the brachytherapy procedure. At the study institution...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9726696/ https://www.ncbi.nlm.nih.gov/pubmed/36000156 http://dx.doi.org/10.1093/jrr/rrac050 |
Sumario: | An estimated gland volume of > 60 cc is a relative contraindication to brachytherapy for prostate cancer. As volume estimation using biopsy ultrasound (Bx-US) alone may be inaccurate, many centers perform additional volume assessments prior to the brachytherapy procedure. At the study institution, computed tomography (CT) based volume assessments were routinely performed on all patients to determine brachytherapy eligibility. This study aimed to determine whether this CT imaging could be omitted for certain Bx-US based gland volume estimates. To investigate this, 1576 consecutive patients that received ultrasound based intraoperatively planned brachytherapy at a single comprehensive cancer center between 2003 and 2021 were reviewed. Gland volume as estimated by Bx-US, CT and magnetic resonance (MR) imaging were compared to intraoperatively contoured gland volume (ICGV) or the larger contoured gland volume on CT for any patients receiving neo-adjuvant androgen deprivation therapy (ADT) for gland downsizing (IM-US-corr). There was a significant difference between IM-US-corr and estimated gland volume for Bx-US (P < 0.001) and MR (P < 0.001), but not CT (P = 0.160). Bx-US and MR tended to underrepresent the IM-US-corr, with a > 20% difference from actual volume in 31% and 59% of cases, respectively. When Bx-US volume was estimated to be < 40 cc, < 50 cc and < 60 cc, an IM-US-corr > 60 cc was encountered in 2%, 5% and 7% of cases, respectively. In contrast, IM-US-corr > 60 cc was encountered in 0.2%, 1% and 2% of cases for CT estimates of < 40 cc, < 50 cc and < 60 cc. In patients with an estimated gland volume of < 50 cc by Bx-US, dedicated pre-operative volume studies are unlikely to alter management. However, patients above this cut-off stand to benefit from the use of additional volume assessment to better delineate gland volume and determine eligibility for brachytherapy. |
---|