Cargando…

Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears

BACKGROUND: Massive rotator cuff tears (MRCTs) with subscapularis (SSC) tears cause severe shoulder dysfunction. In the present study, the influence of SSC tears on three-dimensional (3D) shoulder kinematics during scapular plane abduction in patients with MRCTs was examined. METHODS: This study inc...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamada, Yuji, Kai, Yoshihiro, Kida, Noriyuki, Koda, Hitoshi, Takeshima, Minoru, Hoshi, Kenji, Gamada, Kazuyoshi, Morihara, Toru
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Shoulder and Elbow Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9727484/
https://www.ncbi.nlm.nih.gov/pubmed/35971609
http://dx.doi.org/10.5397/cise.2022.00836
_version_ 1784845032843378688
author Yamada, Yuji
Kai, Yoshihiro
Kida, Noriyuki
Koda, Hitoshi
Takeshima, Minoru
Hoshi, Kenji
Gamada, Kazuyoshi
Morihara, Toru
author_facet Yamada, Yuji
Kai, Yoshihiro
Kida, Noriyuki
Koda, Hitoshi
Takeshima, Minoru
Hoshi, Kenji
Gamada, Kazuyoshi
Morihara, Toru
author_sort Yamada, Yuji
collection PubMed
description BACKGROUND: Massive rotator cuff tears (MRCTs) with subscapularis (SSC) tears cause severe shoulder dysfunction. In the present study, the influence of SSC tears on three-dimensional (3D) shoulder kinematics during scapular plane abduction in patients with MRCTs was examined. METHODS: This study included 15 patients who were divided into two groups: supraspinatus (SSP) and infraspinatus (ISP) tears with SSC tear (torn SSC group: 10 shoulders) or without SSC tear (intact SSC group: 5 shoulders). Single-plane fluoroscopic images during scapular plane elevation and computed tomography (CT)-derived 3D bone models were matched to the fluoroscopic images using two-dimensional (2D)/3D registration techniques. Changes in 3D kinematic results were compared. RESULTS: The humeral head center at the beginning of arm elevation was significantly higher in the torn SSC group than in the intact SSC group (1.8±3.4 mm vs. −1.1±1.6 mm, p<0.05). In the torn SSC group, the center of the humeral head migrated superiorly, then significantly downward at 60° arm elevation (p<0.05). In the intact SSC group, significant difference was not observed in the superior-inferior translation of the humeral head between the elevation angles. CONCLUSIONS: In cases of MRCTs with a torn SSC, the center of the humeral head showed a superior translation at the initial phase of scapular plane abduction followed by inferior translation. These findings indicate the SSC muscle plays an important role in determining the dynamic stability of the glenohumeral joint in a superior-inferior direction in patients with MRCTs.
format Online
Article
Text
id pubmed-9727484
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Shoulder and Elbow Society
record_format MEDLINE/PubMed
spelling pubmed-97274842022-12-15 Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears Yamada, Yuji Kai, Yoshihiro Kida, Noriyuki Koda, Hitoshi Takeshima, Minoru Hoshi, Kenji Gamada, Kazuyoshi Morihara, Toru Clin Shoulder Elb Original Article BACKGROUND: Massive rotator cuff tears (MRCTs) with subscapularis (SSC) tears cause severe shoulder dysfunction. In the present study, the influence of SSC tears on three-dimensional (3D) shoulder kinematics during scapular plane abduction in patients with MRCTs was examined. METHODS: This study included 15 patients who were divided into two groups: supraspinatus (SSP) and infraspinatus (ISP) tears with SSC tear (torn SSC group: 10 shoulders) or without SSC tear (intact SSC group: 5 shoulders). Single-plane fluoroscopic images during scapular plane elevation and computed tomography (CT)-derived 3D bone models were matched to the fluoroscopic images using two-dimensional (2D)/3D registration techniques. Changes in 3D kinematic results were compared. RESULTS: The humeral head center at the beginning of arm elevation was significantly higher in the torn SSC group than in the intact SSC group (1.8±3.4 mm vs. −1.1±1.6 mm, p<0.05). In the torn SSC group, the center of the humeral head migrated superiorly, then significantly downward at 60° arm elevation (p<0.05). In the intact SSC group, significant difference was not observed in the superior-inferior translation of the humeral head between the elevation angles. CONCLUSIONS: In cases of MRCTs with a torn SSC, the center of the humeral head showed a superior translation at the initial phase of scapular plane abduction followed by inferior translation. These findings indicate the SSC muscle plays an important role in determining the dynamic stability of the glenohumeral joint in a superior-inferior direction in patients with MRCTs. Korean Shoulder and Elbow Society 2022-08-16 /pmc/articles/PMC9727484/ /pubmed/35971609 http://dx.doi.org/10.5397/cise.2022.00836 Text en Copyright © 2022 Korean Shoulder and Elbow Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yamada, Yuji
Kai, Yoshihiro
Kida, Noriyuki
Koda, Hitoshi
Takeshima, Minoru
Hoshi, Kenji
Gamada, Kazuyoshi
Morihara, Toru
Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
title Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
title_full Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
title_fullStr Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
title_full_unstemmed Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
title_short Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
title_sort dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9727484/
https://www.ncbi.nlm.nih.gov/pubmed/35971609
http://dx.doi.org/10.5397/cise.2022.00836
work_keys_str_mv AT yamadayuji dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT kaiyoshihiro dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT kidanoriyuki dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT kodahitoshi dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT takeshimaminoru dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT hoshikenji dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT gamadakazuyoshi dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears
AT moriharatoru dynamicthreedimensionalshoulderkinematicsinpatientswithmassiverotatorcufftearsacomparisonofpatientswithandwithoutsubscapularistears