Cargando…

在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物

In order to monitor the risk of pesticide pollutants in drinking water, an analytical method based on online-solid phase extraction coupled with ultra performance liquid chromatography-triple quadrupole mass spectrometry (online-SPE-UPLC-MS/MS) was established for the simultaneous rapid screening an...

Descripción completa

Detalles Bibliográficos
Autores principales: CHEN, Yongyan, LÜ, Jia, ZHANG, Lan, YE, Bixiong, JIN, Ning
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial board of Chinese Journal of Chromatography 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9727740/
https://www.ncbi.nlm.nih.gov/pubmed/36450346
http://dx.doi.org/10.3724/SP.J.1123.2022.07011
_version_ 1784845088815316992
author CHEN, Yongyan
LÜ, Jia
ZHANG, Lan
YE, Bixiong
JIN, Ning
author_facet CHEN, Yongyan
LÜ, Jia
ZHANG, Lan
YE, Bixiong
JIN, Ning
author_sort CHEN, Yongyan
collection PubMed
description In order to monitor the risk of pesticide pollutants in drinking water, an analytical method based on online-solid phase extraction coupled with ultra performance liquid chromatography-triple quadrupole mass spectrometry (online-SPE-UPLC-MS/MS) was established for the simultaneous rapid screening and determination of 107 pesticides and metabolites (organophosphorus, organic nitrogen, organic heterocycle, carbamate, amide, benzoyl urea, neonicotinoid, etc.) in raw water and drinking water. Different injection volumes (5, 10, and 15 mL) were compared. The detection response increased with an increase in the injection volume, but the matrix effect also became more pronounced. Under the premise of ensuring the sensitivity of the method and meeting the detection requirements, the injection volume was selected as 5 mL. Accordingly, the samples were filtered through a 0.22-μm hydrophilic polytetrafluoroethylene filter, and then, 5 mL samples were injected into the online-SPE system by the automatic sampler. After adsorption on an X Bridge C(18) online-SPE column, the samples were washed with pure water and eluted by gradient elution using acetonitrile and 0.1% formic acid aqueous solution as the mobile phases, with separation on an ACQUITY HSS T(3) column. The samples were detected by multiple reaction monitoring with electrospray ionization in positive and negative ion modes, and quantified by an external standard method. Using raw water and drinking water as the sample matrices, the accuracy and precision of the method were verified. The 107 pesticides and metabolites showed good linear relationships in different ranges with correlation coefficients (r(2))>0.995. The limits of detection (LODs, S/N=3) of the method were 0.03-1.5 ng/L, and the limits of quantification (LOQs, S/N=10) were 0.1-5.0 ng/L. The target pesticides were spiked at concentration levels of 1, 20, and 50 ng/L. The spiked recoveries of the 107 targets in raw water and drinking water samples were 60.6%-119.8% and 61.2%-119.0%, respectively. The corresponding relative standard deviations (RSDs, n=6) were 0.3%-18.6% and 0.4%-17.1%. The pesticide residues in raw water and drinking water were determined by this method. Amide herbicides, triazine herbicides, triazole insecticides, carbamate insecticides, and neonicotinoid insecticides had high detection rates. The detected concentrations ranged from 0.1 to 97.1 ng/L in raw water and from 0.1 to 93.6 ng/L in drinking water. The sample consumption of online-SPE method was lower than that in the traditional off-line SPE methods, which greatly improved the convenience of sample collection, storage, and transportation. The samples only need to be filtered before injection and analysis. The method is simple to operate and shows good reproducibility. With this online-SPE method, only 23 min were required from online enrichment to detection completion. The developed method has the advantages of high analytical speed and high sensitivity. The method is suitable for the trace analysis and determination of 107 typical pesticides in raw water and drinking water, which effectively improves the detection efficiency of pesticides in water and has high potential for practical application. It can extend technical support for the pollution-level analysis of typical pesticides and metabolites in drinking water and provide an objective basis for human health risk assessment.
format Online
Article
Text
id pubmed-9727740
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Editorial board of Chinese Journal of Chromatography
record_format MEDLINE/PubMed
spelling pubmed-97277402022-12-13 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物 CHEN, Yongyan LÜ, Jia ZHANG, Lan YE, Bixiong JIN, Ning Se Pu Articles In order to monitor the risk of pesticide pollutants in drinking water, an analytical method based on online-solid phase extraction coupled with ultra performance liquid chromatography-triple quadrupole mass spectrometry (online-SPE-UPLC-MS/MS) was established for the simultaneous rapid screening and determination of 107 pesticides and metabolites (organophosphorus, organic nitrogen, organic heterocycle, carbamate, amide, benzoyl urea, neonicotinoid, etc.) in raw water and drinking water. Different injection volumes (5, 10, and 15 mL) were compared. The detection response increased with an increase in the injection volume, but the matrix effect also became more pronounced. Under the premise of ensuring the sensitivity of the method and meeting the detection requirements, the injection volume was selected as 5 mL. Accordingly, the samples were filtered through a 0.22-μm hydrophilic polytetrafluoroethylene filter, and then, 5 mL samples were injected into the online-SPE system by the automatic sampler. After adsorption on an X Bridge C(18) online-SPE column, the samples were washed with pure water and eluted by gradient elution using acetonitrile and 0.1% formic acid aqueous solution as the mobile phases, with separation on an ACQUITY HSS T(3) column. The samples were detected by multiple reaction monitoring with electrospray ionization in positive and negative ion modes, and quantified by an external standard method. Using raw water and drinking water as the sample matrices, the accuracy and precision of the method were verified. The 107 pesticides and metabolites showed good linear relationships in different ranges with correlation coefficients (r(2))>0.995. The limits of detection (LODs, S/N=3) of the method were 0.03-1.5 ng/L, and the limits of quantification (LOQs, S/N=10) were 0.1-5.0 ng/L. The target pesticides were spiked at concentration levels of 1, 20, and 50 ng/L. The spiked recoveries of the 107 targets in raw water and drinking water samples were 60.6%-119.8% and 61.2%-119.0%, respectively. The corresponding relative standard deviations (RSDs, n=6) were 0.3%-18.6% and 0.4%-17.1%. The pesticide residues in raw water and drinking water were determined by this method. Amide herbicides, triazine herbicides, triazole insecticides, carbamate insecticides, and neonicotinoid insecticides had high detection rates. The detected concentrations ranged from 0.1 to 97.1 ng/L in raw water and from 0.1 to 93.6 ng/L in drinking water. The sample consumption of online-SPE method was lower than that in the traditional off-line SPE methods, which greatly improved the convenience of sample collection, storage, and transportation. The samples only need to be filtered before injection and analysis. The method is simple to operate and shows good reproducibility. With this online-SPE method, only 23 min were required from online enrichment to detection completion. The developed method has the advantages of high analytical speed and high sensitivity. The method is suitable for the trace analysis and determination of 107 typical pesticides in raw water and drinking water, which effectively improves the detection efficiency of pesticides in water and has high potential for practical application. It can extend technical support for the pollution-level analysis of typical pesticides and metabolites in drinking water and provide an objective basis for human health risk assessment. Editorial board of Chinese Journal of Chromatography 2022-12-08 /pmc/articles/PMC9727740/ /pubmed/36450346 http://dx.doi.org/10.3724/SP.J.1123.2022.07011 Text en https://creativecommons.org/licenses/by/4.0/本文是开放获取文章,遵循CC BY 4.0协议 https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Articles
CHEN, Yongyan
LÜ, Jia
ZHANG, Lan
YE, Bixiong
JIN, Ning
在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
title 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
title_full 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
title_fullStr 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
title_full_unstemmed 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
title_short 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
title_sort 在线固相萃取-超高效液相色谱-三重四极杆质谱法测定水源水和饮用水中107种典型农药及代谢产物
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9727740/
https://www.ncbi.nlm.nih.gov/pubmed/36450346
http://dx.doi.org/10.3724/SP.J.1123.2022.07011
work_keys_str_mv AT chenyongyan zàixiàngùxiāngcuìqǔchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐyuánshuǐhéyǐnyòngshuǐzhōng107zhǒngdiǎnxíngnóngyàojídàixièchǎnwù
AT lujia zàixiàngùxiāngcuìqǔchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐyuánshuǐhéyǐnyòngshuǐzhōng107zhǒngdiǎnxíngnóngyàojídàixièchǎnwù
AT zhanglan zàixiàngùxiāngcuìqǔchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐyuánshuǐhéyǐnyòngshuǐzhōng107zhǒngdiǎnxíngnóngyàojídàixièchǎnwù
AT yebixiong zàixiàngùxiāngcuìqǔchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐyuánshuǐhéyǐnyòngshuǐzhōng107zhǒngdiǎnxíngnóngyàojídàixièchǎnwù
AT jinning zàixiàngùxiāngcuìqǔchāogāoxiàoyèxiāngsèpǔsānzhòngsìjígānzhìpǔfǎcèdìngshuǐyuánshuǐhéyǐnyòngshuǐzhōng107zhǒngdiǎnxíngnóngyàojídàixièchǎnwù