Cargando…
Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer
Currently early diagnosis of malignant lesions at the periphery of lung parenchyma requires guidance of the biopsy needle catheter from the bronchoscope into the smaller peripheral airways via harmful X-ray radiation. Previously, we developed an image-guided system, iMTECH which uses electromagnetic...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9728835/ https://www.ncbi.nlm.nih.gov/pubmed/36476838 http://dx.doi.org/10.1371/journal.pone.0277938 |
_version_ | 1784845350259916800 |
---|---|
author | Gruionu, Lucian Gheorghe Udriștoiu, Anca Loredana Iacob, Andreea Valentina Constantinescu, Cătălin Stan, Răzvan Gruionu, Gabriel |
author_facet | Gruionu, Lucian Gheorghe Udriștoiu, Anca Loredana Iacob, Andreea Valentina Constantinescu, Cătălin Stan, Răzvan Gruionu, Gabriel |
author_sort | Gruionu, Lucian Gheorghe |
collection | PubMed |
description | Currently early diagnosis of malignant lesions at the periphery of lung parenchyma requires guidance of the biopsy needle catheter from the bronchoscope into the smaller peripheral airways via harmful X-ray radiation. Previously, we developed an image-guided system, iMTECH which uses electromagnetic tracking and although it increases the precision of biopsy collection and minimizes the use of harmful X-ray radiation during the interventional procedures, it only traces the tip of the biopsy catheter leaving the remaining catheter untraceable in real time and therefore increasing image registration error. To address this issue, we developed a shape sensing guidance system containing a fiber-Bragg grating (FBG) catheter and an artificial intelligence (AI) software, AIrShape to track and guide the entire biopsy instrument inside the lung airways, without radiation or electromagnetic navigation. We used a FBG fiber with one central and three peripheral cores positioned at 120° from each other, an array of 25 draw tower gratings with 1cm/3nm spacing, 2 mm grating length, Ormocer-T coating, and a total outer diameter of 0.2 mm. The FBG fiber was placed in the working channel of a custom made three-lumen catheter with a tip bending mechanism (FBG catheter). The AIrShape software determines the position of the FBG catheter by superimposing its position to the lung airway center lines using an AI algorithm. The feasibility of the FBG system was tested in an anatomically accurate lung airway model and validated visually and with the iMTECH platform. The results prove a viable shape-sensing hardware and software navigation solution for flexible medical instruments to reach the peripheral airways. During future studies, the feasibility of FBG catheter will be tested in pre-clinical animal models. |
format | Online Article Text |
id | pubmed-9728835 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-97288352022-12-08 Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer Gruionu, Lucian Gheorghe Udriștoiu, Anca Loredana Iacob, Andreea Valentina Constantinescu, Cătălin Stan, Răzvan Gruionu, Gabriel PLoS One Research Article Currently early diagnosis of malignant lesions at the periphery of lung parenchyma requires guidance of the biopsy needle catheter from the bronchoscope into the smaller peripheral airways via harmful X-ray radiation. Previously, we developed an image-guided system, iMTECH which uses electromagnetic tracking and although it increases the precision of biopsy collection and minimizes the use of harmful X-ray radiation during the interventional procedures, it only traces the tip of the biopsy catheter leaving the remaining catheter untraceable in real time and therefore increasing image registration error. To address this issue, we developed a shape sensing guidance system containing a fiber-Bragg grating (FBG) catheter and an artificial intelligence (AI) software, AIrShape to track and guide the entire biopsy instrument inside the lung airways, without radiation or electromagnetic navigation. We used a FBG fiber with one central and three peripheral cores positioned at 120° from each other, an array of 25 draw tower gratings with 1cm/3nm spacing, 2 mm grating length, Ormocer-T coating, and a total outer diameter of 0.2 mm. The FBG fiber was placed in the working channel of a custom made three-lumen catheter with a tip bending mechanism (FBG catheter). The AIrShape software determines the position of the FBG catheter by superimposing its position to the lung airway center lines using an AI algorithm. The feasibility of the FBG system was tested in an anatomically accurate lung airway model and validated visually and with the iMTECH platform. The results prove a viable shape-sensing hardware and software navigation solution for flexible medical instruments to reach the peripheral airways. During future studies, the feasibility of FBG catheter will be tested in pre-clinical animal models. Public Library of Science 2022-12-07 /pmc/articles/PMC9728835/ /pubmed/36476838 http://dx.doi.org/10.1371/journal.pone.0277938 Text en © 2022 Gruionu et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Gruionu, Lucian Gheorghe Udriștoiu, Anca Loredana Iacob, Andreea Valentina Constantinescu, Cătălin Stan, Răzvan Gruionu, Gabriel Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
title | Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
title_full | Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
title_fullStr | Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
title_full_unstemmed | Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
title_short | Feasibility of a lung airway navigation system using fiber-Bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
title_sort | feasibility of a lung airway navigation system using fiber-bragg shape sensing and artificial intelligence for early diagnosis of lung cancer |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9728835/ https://www.ncbi.nlm.nih.gov/pubmed/36476838 http://dx.doi.org/10.1371/journal.pone.0277938 |
work_keys_str_mv | AT gruionuluciangheorghe feasibilityofalungairwaynavigationsystemusingfiberbraggshapesensingandartificialintelligenceforearlydiagnosisoflungcancer AT udristoiuancaloredana feasibilityofalungairwaynavigationsystemusingfiberbraggshapesensingandartificialintelligenceforearlydiagnosisoflungcancer AT iacobandreeavalentina feasibilityofalungairwaynavigationsystemusingfiberbraggshapesensingandartificialintelligenceforearlydiagnosisoflungcancer AT constantinescucatalin feasibilityofalungairwaynavigationsystemusingfiberbraggshapesensingandartificialintelligenceforearlydiagnosisoflungcancer AT stanrazvan feasibilityofalungairwaynavigationsystemusingfiberbraggshapesensingandartificialintelligenceforearlydiagnosisoflungcancer AT gruionugabriel feasibilityofalungairwaynavigationsystemusingfiberbraggshapesensingandartificialintelligenceforearlydiagnosisoflungcancer |