Cargando…

Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites

The influence of protocol standardization between laboratories on their replicability of preclinical results has not been addressed in a systematic way. While standardization is considered good research practice as a means to control for undesired external noise (i.e., highly variable results), some...

Descripción completa

Detalles Bibliográficos
Autores principales: Arroyo-Araujo, María, Voelkl, Bernhard, Laloux, Clément, Novak, Janja, Koopmans, Bastijn, Waldron, Ann-Marie, Seiffert, Isabel, Stirling, Helen, Aulehner, Katharina, Janhunen, Sanna K., Ramboz, Sylvie, Potschka, Heidrun, Holappa, Johanna, Fine, Tania, Loos, Maarten, Boulanger, Bruno, Würbel, Hanno, Kas, Martien J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9728859/
https://www.ncbi.nlm.nih.gov/pubmed/36417471
http://dx.doi.org/10.1371/journal.pbio.3001886
_version_ 1784845357168984064
author Arroyo-Araujo, María
Voelkl, Bernhard
Laloux, Clément
Novak, Janja
Koopmans, Bastijn
Waldron, Ann-Marie
Seiffert, Isabel
Stirling, Helen
Aulehner, Katharina
Janhunen, Sanna K.
Ramboz, Sylvie
Potschka, Heidrun
Holappa, Johanna
Fine, Tania
Loos, Maarten
Boulanger, Bruno
Würbel, Hanno
Kas, Martien J.
author_facet Arroyo-Araujo, María
Voelkl, Bernhard
Laloux, Clément
Novak, Janja
Koopmans, Bastijn
Waldron, Ann-Marie
Seiffert, Isabel
Stirling, Helen
Aulehner, Katharina
Janhunen, Sanna K.
Ramboz, Sylvie
Potschka, Heidrun
Holappa, Johanna
Fine, Tania
Loos, Maarten
Boulanger, Bruno
Würbel, Hanno
Kas, Martien J.
author_sort Arroyo-Araujo, María
collection PubMed
description The influence of protocol standardization between laboratories on their replicability of preclinical results has not been addressed in a systematic way. While standardization is considered good research practice as a means to control for undesired external noise (i.e., highly variable results), some reports suggest that standardized protocols may lead to idiosyncratic results, thus undermining replicability. Through the EQIPD consortium, a multi-lab collaboration between academic and industry partners, we aimed to elucidate parameters that impact the replicability of preclinical animal studies. To this end, 3 experimental protocols were implemented across 7 laboratories. The replicability of results was determined using the distance travelled in an open field after administration of pharmacological compounds known to modulate locomotor activity (MK-801, diazepam, and clozapine) in C57BL/6 mice as a worked example. The goal was to determine whether harmonization of study protocols across laboratories improves the replicability of the results and whether replicability can be further improved by systematic variation (heterogenization) of 2 environmental factors (time of testing and light intensity during testing) within laboratories. Protocols were tested in 3 consecutive stages and differed in the extent of harmonization across laboratories and standardization within laboratories: stage 1, minimally aligned across sites (local protocol); stage 2, fully aligned across sites (harmonized protocol) with and without systematic variation (standardized and heterogenized cohort); and stage 3, fully aligned across sites (standardized protocol) with a different compound. All protocols resulted in consistent treatment effects across laboratories, which were also replicated within laboratories across the different stages. Harmonization of protocols across laboratories reduced between-lab variability substantially compared to each lab using their local protocol. In contrast, the environmental factors chosen to introduce systematic variation within laboratories did not affect the behavioral outcome. Therefore, heterogenization did not reduce between-lab variability further compared to the harmonization of the standardized protocol. Altogether, these findings demonstrate that subtle variations between lab-specific study protocols may introduce variation across independent replicate studies even after protocol harmonization and that systematic heterogenization of environmental factors may not be sufficient to account for such between-lab variation. Differences in replicability of results within and between laboratories highlight the ubiquity of study-specific variation due to between-lab variability, the importance of transparent and fine-grained reporting of methodologies and research protocols, and the importance of independent study replication.
format Online
Article
Text
id pubmed-9728859
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-97288592022-12-08 Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites Arroyo-Araujo, María Voelkl, Bernhard Laloux, Clément Novak, Janja Koopmans, Bastijn Waldron, Ann-Marie Seiffert, Isabel Stirling, Helen Aulehner, Katharina Janhunen, Sanna K. Ramboz, Sylvie Potschka, Heidrun Holappa, Johanna Fine, Tania Loos, Maarten Boulanger, Bruno Würbel, Hanno Kas, Martien J. PLoS Biol Meta-Research Article The influence of protocol standardization between laboratories on their replicability of preclinical results has not been addressed in a systematic way. While standardization is considered good research practice as a means to control for undesired external noise (i.e., highly variable results), some reports suggest that standardized protocols may lead to idiosyncratic results, thus undermining replicability. Through the EQIPD consortium, a multi-lab collaboration between academic and industry partners, we aimed to elucidate parameters that impact the replicability of preclinical animal studies. To this end, 3 experimental protocols were implemented across 7 laboratories. The replicability of results was determined using the distance travelled in an open field after administration of pharmacological compounds known to modulate locomotor activity (MK-801, diazepam, and clozapine) in C57BL/6 mice as a worked example. The goal was to determine whether harmonization of study protocols across laboratories improves the replicability of the results and whether replicability can be further improved by systematic variation (heterogenization) of 2 environmental factors (time of testing and light intensity during testing) within laboratories. Protocols were tested in 3 consecutive stages and differed in the extent of harmonization across laboratories and standardization within laboratories: stage 1, minimally aligned across sites (local protocol); stage 2, fully aligned across sites (harmonized protocol) with and without systematic variation (standardized and heterogenized cohort); and stage 3, fully aligned across sites (standardized protocol) with a different compound. All protocols resulted in consistent treatment effects across laboratories, which were also replicated within laboratories across the different stages. Harmonization of protocols across laboratories reduced between-lab variability substantially compared to each lab using their local protocol. In contrast, the environmental factors chosen to introduce systematic variation within laboratories did not affect the behavioral outcome. Therefore, heterogenization did not reduce between-lab variability further compared to the harmonization of the standardized protocol. Altogether, these findings demonstrate that subtle variations between lab-specific study protocols may introduce variation across independent replicate studies even after protocol harmonization and that systematic heterogenization of environmental factors may not be sufficient to account for such between-lab variation. Differences in replicability of results within and between laboratories highlight the ubiquity of study-specific variation due to between-lab variability, the importance of transparent and fine-grained reporting of methodologies and research protocols, and the importance of independent study replication. Public Library of Science 2022-11-23 /pmc/articles/PMC9728859/ /pubmed/36417471 http://dx.doi.org/10.1371/journal.pbio.3001886 Text en © 2022 Arroyo-Araujo et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Meta-Research Article
Arroyo-Araujo, María
Voelkl, Bernhard
Laloux, Clément
Novak, Janja
Koopmans, Bastijn
Waldron, Ann-Marie
Seiffert, Isabel
Stirling, Helen
Aulehner, Katharina
Janhunen, Sanna K.
Ramboz, Sylvie
Potschka, Heidrun
Holappa, Johanna
Fine, Tania
Loos, Maarten
Boulanger, Bruno
Würbel, Hanno
Kas, Martien J.
Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites
title Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites
title_full Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites
title_fullStr Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites
title_full_unstemmed Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites
title_short Systematic assessment of the replicability and generalizability of preclinical findings: Impact of protocol harmonization across laboratory sites
title_sort systematic assessment of the replicability and generalizability of preclinical findings: impact of protocol harmonization across laboratory sites
topic Meta-Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9728859/
https://www.ncbi.nlm.nih.gov/pubmed/36417471
http://dx.doi.org/10.1371/journal.pbio.3001886
work_keys_str_mv AT arroyoaraujomaria systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT voelklbernhard systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT lalouxclement systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT novakjanja systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT koopmansbastijn systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT waldronannmarie systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT seiffertisabel systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT stirlinghelen systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT aulehnerkatharina systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT janhunensannak systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT rambozsylvie systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT potschkaheidrun systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT holappajohanna systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT finetania systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT loosmaarten systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT boulangerbruno systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT wurbelhanno systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites
AT kasmartienj systematicassessmentofthereplicabilityandgeneralizabilityofpreclinicalfindingsimpactofprotocolharmonizationacrosslaboratorysites