Temperature-controlled ablation of the mitral isthmus line using the novel DiamondTemp ablation system
BACKGROUND: The novel DiamondTemp™ (DT)-catheter (Medtronic(®)) was designed for high-power, short-duration ablation in a temperature-controlled mode. AIM: To evaluate the performance of the DT-catheter for ablation of the mitral isthmus line (MIL) using two different energy dosing strategies. MATER...
Autores principales: | Rottner, Laura, My, Ilaria, Schleberger, Ruben, Moser, Fabian, Moser, Julia, Kirchhof, Paulus, Ouyang, Feifan, Rillig, Andreas, Metzner, Andreas, Reissmann, Bruno |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9729688/ https://www.ncbi.nlm.nih.gov/pubmed/36505349 http://dx.doi.org/10.3389/fcvm.2022.1046956 |
Ejemplares similares
-
Cryoballoon ablation guided by a novel wide-band dielectric imaging system
por: Rottner, Laura, et al.
Publicado: (2022) -
Ablation of Outflow Tract Arrhythmias in Patients With and Without Structural Heart Disease—A Comparative Analysis
por: Schleberger, Ruben, et al.
Publicado: (2022) -
Pulsed-field ablation based pulmonary vein isolation: reconnection pattern and comparison to cryoballoon ablation
por: Lemoine, M, et al.
Publicado: (2023) -
Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario
por: Lemoine, Marc D., et al.
Publicado: (2022) -
Update Vorhofflimmern: Die ESC-Leitlinien 2020 sowie aktuelle Daten zur frühen antiarrhythmischen Therapie
por: Schleberger, Ruben, et al.
Publicado: (2021)