Cargando…
Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure
BACKGROUND: Studies demonstrated the bond strength enhancement and the decrease in degradation of the adhesive interface after applying either self-etch adhesives or two-step, etch-and-rinse adhesives under an electric field. However, the presence of dentinal fluid driven by the pulpal pressure in v...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9730621/ https://www.ncbi.nlm.nih.gov/pubmed/36482395 http://dx.doi.org/10.1186/s12903-022-02632-1 |
_version_ | 1784845716595671040 |
---|---|
author | Ajcharanukul, Orapin Santikulluk, Peeraya Sasingha, Palat Sabpawat, Sirithorn Sukyanan, Kanokporn |
author_facet | Ajcharanukul, Orapin Santikulluk, Peeraya Sasingha, Palat Sabpawat, Sirithorn Sukyanan, Kanokporn |
author_sort | Ajcharanukul, Orapin |
collection | PubMed |
description | BACKGROUND: Studies demonstrated the bond strength enhancement and the decrease in degradation of the adhesive interface after applying either self-etch adhesives or two-step, etch-and-rinse adhesives under an electric field. However, the presence of dentinal fluid driven by the pulpal pressure in vivo is a profounding factor affecting both the sealing ability and bond strength of adhesives. This study aimed to evaluate the effect of three-step etch-and-rinse and two-step self-etch adhesives when applied with iontophoresis under simulated pulpal pressure on the permeability of dentin, resin infiltration, and the sealing ability of resin composite. METHODS: The experiments were done on 32 recently extracted premolars, randomly assigned into four groups (n = 8) according to two adhesive systems (SBMP and SE), applied following the manufacturer’s instructions (control) for two groups or with iontophoresis for the others (SBMPi and SEi). For the iontophoresis, the anodal current was applied at 75 μA for 20 s through the cavity electrode during the bond. The fluid flow rate of dentin was recorded after cavity preparation (smear-layer-covered dentin; T1), bonding (T2), and composite restoration (T3) during the maintained pulpal pressure of 20 mm Hg. The flow rates were expressed as a percentage relative to the initial smear-layer-covered value for each specimen. Results were analyzed using repeated measures ANOVA. Scanning electron microscopy (SEM) was performed to observe the resin/dentin interface. RESULTS: There were no significant increases in the mean flow rates from T1 to T3 in the SBMP (P = 0.355), while these changes in the SE were significant between T1 (100%) and T2 (166.77%) and T1 and T3 (221.16%) (P = 0.002; one-way RM ANOVA; Holm-Sidak test). For the iontophoresis groups, the mean flow rates decreased significantly from T1 to T2 and T1 to T3 of both SBMPi (T2 = 86.43, and T3 = 79.53; P < 0.001) and SEi groups (T2 = 87.96, and T3 = 81.48; P = 0.004). The iontophoresis of both adhesives produced the optimal resin infiltration with improved quality of the hybrid layer and resin tags. CONCLUSIONS: SBMP bonded with or without iontophoresis performed better sealing ability than SE under the same condition. Both adhesives applied with anodal iontophoresis significantly decreased the dentin permeability, contributing to the improved resin infiltration. |
format | Online Article Text |
id | pubmed-9730621 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-97306212022-12-09 Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure Ajcharanukul, Orapin Santikulluk, Peeraya Sasingha, Palat Sabpawat, Sirithorn Sukyanan, Kanokporn BMC Oral Health Research BACKGROUND: Studies demonstrated the bond strength enhancement and the decrease in degradation of the adhesive interface after applying either self-etch adhesives or two-step, etch-and-rinse adhesives under an electric field. However, the presence of dentinal fluid driven by the pulpal pressure in vivo is a profounding factor affecting both the sealing ability and bond strength of adhesives. This study aimed to evaluate the effect of three-step etch-and-rinse and two-step self-etch adhesives when applied with iontophoresis under simulated pulpal pressure on the permeability of dentin, resin infiltration, and the sealing ability of resin composite. METHODS: The experiments were done on 32 recently extracted premolars, randomly assigned into four groups (n = 8) according to two adhesive systems (SBMP and SE), applied following the manufacturer’s instructions (control) for two groups or with iontophoresis for the others (SBMPi and SEi). For the iontophoresis, the anodal current was applied at 75 μA for 20 s through the cavity electrode during the bond. The fluid flow rate of dentin was recorded after cavity preparation (smear-layer-covered dentin; T1), bonding (T2), and composite restoration (T3) during the maintained pulpal pressure of 20 mm Hg. The flow rates were expressed as a percentage relative to the initial smear-layer-covered value for each specimen. Results were analyzed using repeated measures ANOVA. Scanning electron microscopy (SEM) was performed to observe the resin/dentin interface. RESULTS: There were no significant increases in the mean flow rates from T1 to T3 in the SBMP (P = 0.355), while these changes in the SE were significant between T1 (100%) and T2 (166.77%) and T1 and T3 (221.16%) (P = 0.002; one-way RM ANOVA; Holm-Sidak test). For the iontophoresis groups, the mean flow rates decreased significantly from T1 to T2 and T1 to T3 of both SBMPi (T2 = 86.43, and T3 = 79.53; P < 0.001) and SEi groups (T2 = 87.96, and T3 = 81.48; P = 0.004). The iontophoresis of both adhesives produced the optimal resin infiltration with improved quality of the hybrid layer and resin tags. CONCLUSIONS: SBMP bonded with or without iontophoresis performed better sealing ability than SE under the same condition. Both adhesives applied with anodal iontophoresis significantly decreased the dentin permeability, contributing to the improved resin infiltration. BioMed Central 2022-12-08 /pmc/articles/PMC9730621/ /pubmed/36482395 http://dx.doi.org/10.1186/s12903-022-02632-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Ajcharanukul, Orapin Santikulluk, Peeraya Sasingha, Palat Sabpawat, Sirithorn Sukyanan, Kanokporn Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
title | Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
title_full | Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
title_fullStr | Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
title_full_unstemmed | Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
title_short | Iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
title_sort | iontophoresis effects of two-step self-etch and total-etch systems on dentin permeability and sealing of composite restoration under simulated pulpal pressure |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9730621/ https://www.ncbi.nlm.nih.gov/pubmed/36482395 http://dx.doi.org/10.1186/s12903-022-02632-1 |
work_keys_str_mv | AT ajcharanukulorapin iontophoresiseffectsoftwostepselfetchandtotaletchsystemsondentinpermeabilityandsealingofcompositerestorationundersimulatedpulpalpressure AT santikullukpeeraya iontophoresiseffectsoftwostepselfetchandtotaletchsystemsondentinpermeabilityandsealingofcompositerestorationundersimulatedpulpalpressure AT sasinghapalat iontophoresiseffectsoftwostepselfetchandtotaletchsystemsondentinpermeabilityandsealingofcompositerestorationundersimulatedpulpalpressure AT sabpawatsirithorn iontophoresiseffectsoftwostepselfetchandtotaletchsystemsondentinpermeabilityandsealingofcompositerestorationundersimulatedpulpalpressure AT sukyanankanokporn iontophoresiseffectsoftwostepselfetchandtotaletchsystemsondentinpermeabilityandsealingofcompositerestorationundersimulatedpulpalpressure |