Cargando…

Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning

INTRODUCTION: Measurement of torsional deformities and varus alignment in the canine femur is clinically and surgically important but difficult. Computed tomography (CT) generates true three-dimensional (3D) information and is used to overcome the limitations of radiography. The 3D CT images can be...

Descripción completa

Detalles Bibliográficos
Autores principales: Brühschwein, Andreas, Schmitz, Bronson, Zöllner, Martin, Reese, Sven, Meyer-Lindenberg, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9730830/
https://www.ncbi.nlm.nih.gov/pubmed/36504862
http://dx.doi.org/10.3389/fvets.2022.1019215
_version_ 1784845769277177856
author Brühschwein, Andreas
Schmitz, Bronson
Zöllner, Martin
Reese, Sven
Meyer-Lindenberg, Andrea
author_facet Brühschwein, Andreas
Schmitz, Bronson
Zöllner, Martin
Reese, Sven
Meyer-Lindenberg, Andrea
author_sort Brühschwein, Andreas
collection PubMed
description INTRODUCTION: Measurement of torsional deformities and varus alignment in the canine femur is clinically and surgically important but difficult. Computed tomography (CT) generates true three-dimensional (3D) information and is used to overcome the limitations of radiography. The 3D CT images can be rotated freely, but the final view for angle measurements remains a subjective variable decision, especially in severe and complex angular and torsional deformities. The aim of this study was the development of a technique to measure femoral angles in a truly three-dimensional way, independent of femoral positioning. METHODS: To be able to set reference points in any image and at arbitrary positions of the CT series, the 3D coordinates of the reference points were used for mathematical calculation of the angle measurements using the 3D medical imaging Software VoXim(®). Anatomical reference points were described in multiplanar reconstructions and volume rendering CT. A 3D bone-centered coordinate system was introduced and aligned with the anatomical planes of the femur. For torsion angle measurements, the transverse projection plane was mathematically defined by orthogonality to the longitudinal diaphyseal axis. For varus angle measurements, the dorsal plane was defined by a femoral retrocondylar axis. Independence positioning was tested by comparison of angle measurement results in repeated scans of 13 femur bones in different parallel and two double oblique (15/45°) positions in the gantry. Femoralvarus (or valgus), neck version (torsion), and inclination angles were measured, each in two variations. RESULTS: Resulting mean differences ranged between –0.9° and 1.3° for all six determined types of angles and in a difference of <1° for 17 out of 18 comparisons by subtraction of the mean angles between different positions, with one outlier of 1.3°. Intra- and inter-observer agreements determined by repeated measurements resulted in coefficients of variation for repeated measurements between 0.2 and 13.5%. DISCUSSION: The introduction of a bone-centered 3D coordinate system and mathematical definition of projection planes enabled 3D CT measurements of canine femoral varus and neck version and inclination angles. Agreement between angular measurements results of bones scanned in different positions on the CT table demonstrated that the technique is independent of femoral positioning.
format Online
Article
Text
id pubmed-9730830
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-97308302022-12-09 Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning Brühschwein, Andreas Schmitz, Bronson Zöllner, Martin Reese, Sven Meyer-Lindenberg, Andrea Front Vet Sci Veterinary Science INTRODUCTION: Measurement of torsional deformities and varus alignment in the canine femur is clinically and surgically important but difficult. Computed tomography (CT) generates true three-dimensional (3D) information and is used to overcome the limitations of radiography. The 3D CT images can be rotated freely, but the final view for angle measurements remains a subjective variable decision, especially in severe and complex angular and torsional deformities. The aim of this study was the development of a technique to measure femoral angles in a truly three-dimensional way, independent of femoral positioning. METHODS: To be able to set reference points in any image and at arbitrary positions of the CT series, the 3D coordinates of the reference points were used for mathematical calculation of the angle measurements using the 3D medical imaging Software VoXim(®). Anatomical reference points were described in multiplanar reconstructions and volume rendering CT. A 3D bone-centered coordinate system was introduced and aligned with the anatomical planes of the femur. For torsion angle measurements, the transverse projection plane was mathematically defined by orthogonality to the longitudinal diaphyseal axis. For varus angle measurements, the dorsal plane was defined by a femoral retrocondylar axis. Independence positioning was tested by comparison of angle measurement results in repeated scans of 13 femur bones in different parallel and two double oblique (15/45°) positions in the gantry. Femoralvarus (or valgus), neck version (torsion), and inclination angles were measured, each in two variations. RESULTS: Resulting mean differences ranged between –0.9° and 1.3° for all six determined types of angles and in a difference of <1° for 17 out of 18 comparisons by subtraction of the mean angles between different positions, with one outlier of 1.3°. Intra- and inter-observer agreements determined by repeated measurements resulted in coefficients of variation for repeated measurements between 0.2 and 13.5%. DISCUSSION: The introduction of a bone-centered 3D coordinate system and mathematical definition of projection planes enabled 3D CT measurements of canine femoral varus and neck version and inclination angles. Agreement between angular measurements results of bones scanned in different positions on the CT table demonstrated that the technique is independent of femoral positioning. Frontiers Media S.A. 2022-11-24 /pmc/articles/PMC9730830/ /pubmed/36504862 http://dx.doi.org/10.3389/fvets.2022.1019215 Text en Copyright © 2022 Brühschwein, Schmitz, Zöllner, Reese and Meyer-Lindenberg. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Brühschwein, Andreas
Schmitz, Bronson
Zöllner, Martin
Reese, Sven
Meyer-Lindenberg, Andrea
Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
title Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
title_full Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
title_fullStr Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
title_full_unstemmed Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
title_short Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
title_sort introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9730830/
https://www.ncbi.nlm.nih.gov/pubmed/36504862
http://dx.doi.org/10.3389/fvets.2022.1019215
work_keys_str_mv AT bruhschweinandreas introductionofabonecenteredthreedimensionalcoordinatesystemenablescomputedtomographiccaninefemoralanglemeasurementsindependentofpositioning
AT schmitzbronson introductionofabonecenteredthreedimensionalcoordinatesystemenablescomputedtomographiccaninefemoralanglemeasurementsindependentofpositioning
AT zollnermartin introductionofabonecenteredthreedimensionalcoordinatesystemenablescomputedtomographiccaninefemoralanglemeasurementsindependentofpositioning
AT reesesven introductionofabonecenteredthreedimensionalcoordinatesystemenablescomputedtomographiccaninefemoralanglemeasurementsindependentofpositioning
AT meyerlindenbergandrea introductionofabonecenteredthreedimensionalcoordinatesystemenablescomputedtomographiccaninefemoralanglemeasurementsindependentofpositioning