Cargando…
A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability
BACKGROUND: Photoplethysmography (PPG) is a low-cost and easy-to-implement method to measure vital signs, including heart rate (HR) and pulse rate variability (PRV) which widely used as a substitute of heart rate variability (HRV). The method is used in various wearable devices. For example, Samsung...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9731465/ https://www.ncbi.nlm.nih.gov/pubmed/36480505 http://dx.doi.org/10.1371/journal.pone.0268361 |
_version_ | 1784845909018804224 |
---|---|
author | Sarhaddi, Fatemeh Kazemi, Kianoosh Azimi, Iman Cao, Rui Niela-Vilén, Hannakaisa Axelin, Anna Liljeberg, Pasi Rahmani, Amir M. |
author_facet | Sarhaddi, Fatemeh Kazemi, Kianoosh Azimi, Iman Cao, Rui Niela-Vilén, Hannakaisa Axelin, Anna Liljeberg, Pasi Rahmani, Amir M. |
author_sort | Sarhaddi, Fatemeh |
collection | PubMed |
description | BACKGROUND: Photoplethysmography (PPG) is a low-cost and easy-to-implement method to measure vital signs, including heart rate (HR) and pulse rate variability (PRV) which widely used as a substitute of heart rate variability (HRV). The method is used in various wearable devices. For example, Samsung smartwatches are PPG-based open-source wristbands used in remote well-being monitoring and fitness applications. However, PPG is highly susceptible to motion artifacts and environmental noise. A validation study is required to investigate the accuracy of PPG-based wearable devices in free-living conditions. OBJECTIVE: We evaluate the accuracy of PPG signals—collected by the Samsung Gear Sport smartwatch in free-living conditions—in terms of HR and time-domain and frequency-domain HRV parameters against a medical-grade chest electrocardiogram (ECG) monitor. METHODS: We conducted 24-hours monitoring using a Samsung Gear Sport smartwatch and a Shimmer3 ECG device. The monitoring included 28 participants (14 male and 14 female), where they engaged in their daily routines. We evaluated HR and HRV parameters during the sleep and awake time. The parameters extracted from the smartwatch were compared against the ECG reference. For the comparison, we employed the Pearson correlation coefficient, Bland-Altman plot, and linear regression methods. RESULTS: We found a significantly high positive correlation between the smartwatch’s and Shimmer ECG’s HR, time-domain HRV, LF, and HF and a significant moderate positive correlation between the smartwatch’s and shimmer ECG’s LF/HF during sleep time. The mean biases of HR, time-domain HRV, and LF/HF were low, while the biases of LF and HF were moderate during sleep. The regression analysis showed low error variances of HR, AVNN, and pNN50, moderate error variances of SDNN, RMSSD, LF, and HF, and high error variances of LF/HF during sleep. During the awake time, there was a significantly high positive correlation of AVNN and a moderate positive correlation of HR, while the other parameters indicated significantly low positive correlations. RMSSD and SDNN showed low mean biases, and the other parameters had moderate mean biases. In addition, AVNN had moderate error variance while the other parameters indicated high error variances. CONCLUSION: The Samsung smartwatch provides acceptable HR, time-domain HRV, LF, and HF parameters during sleep time. In contrast, during the awake time, AVNN and HR show satisfactory accuracy, and the other HRV parameters have high errors. |
format | Online Article Text |
id | pubmed-9731465 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-97314652022-12-09 A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability Sarhaddi, Fatemeh Kazemi, Kianoosh Azimi, Iman Cao, Rui Niela-Vilén, Hannakaisa Axelin, Anna Liljeberg, Pasi Rahmani, Amir M. PLoS One Research Article BACKGROUND: Photoplethysmography (PPG) is a low-cost and easy-to-implement method to measure vital signs, including heart rate (HR) and pulse rate variability (PRV) which widely used as a substitute of heart rate variability (HRV). The method is used in various wearable devices. For example, Samsung smartwatches are PPG-based open-source wristbands used in remote well-being monitoring and fitness applications. However, PPG is highly susceptible to motion artifacts and environmental noise. A validation study is required to investigate the accuracy of PPG-based wearable devices in free-living conditions. OBJECTIVE: We evaluate the accuracy of PPG signals—collected by the Samsung Gear Sport smartwatch in free-living conditions—in terms of HR and time-domain and frequency-domain HRV parameters against a medical-grade chest electrocardiogram (ECG) monitor. METHODS: We conducted 24-hours monitoring using a Samsung Gear Sport smartwatch and a Shimmer3 ECG device. The monitoring included 28 participants (14 male and 14 female), where they engaged in their daily routines. We evaluated HR and HRV parameters during the sleep and awake time. The parameters extracted from the smartwatch were compared against the ECG reference. For the comparison, we employed the Pearson correlation coefficient, Bland-Altman plot, and linear regression methods. RESULTS: We found a significantly high positive correlation between the smartwatch’s and Shimmer ECG’s HR, time-domain HRV, LF, and HF and a significant moderate positive correlation between the smartwatch’s and shimmer ECG’s LF/HF during sleep time. The mean biases of HR, time-domain HRV, and LF/HF were low, while the biases of LF and HF were moderate during sleep. The regression analysis showed low error variances of HR, AVNN, and pNN50, moderate error variances of SDNN, RMSSD, LF, and HF, and high error variances of LF/HF during sleep. During the awake time, there was a significantly high positive correlation of AVNN and a moderate positive correlation of HR, while the other parameters indicated significantly low positive correlations. RMSSD and SDNN showed low mean biases, and the other parameters had moderate mean biases. In addition, AVNN had moderate error variance while the other parameters indicated high error variances. CONCLUSION: The Samsung smartwatch provides acceptable HR, time-domain HRV, LF, and HF parameters during sleep time. In contrast, during the awake time, AVNN and HR show satisfactory accuracy, and the other HRV parameters have high errors. Public Library of Science 2022-12-08 /pmc/articles/PMC9731465/ /pubmed/36480505 http://dx.doi.org/10.1371/journal.pone.0268361 Text en © 2022 Sarhaddi et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Sarhaddi, Fatemeh Kazemi, Kianoosh Azimi, Iman Cao, Rui Niela-Vilén, Hannakaisa Axelin, Anna Liljeberg, Pasi Rahmani, Amir M. A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability |
title | A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability |
title_full | A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability |
title_fullStr | A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability |
title_full_unstemmed | A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability |
title_short | A comprehensive accuracy assessment of Samsung smartwatch heart rate and heart rate variability |
title_sort | comprehensive accuracy assessment of samsung smartwatch heart rate and heart rate variability |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9731465/ https://www.ncbi.nlm.nih.gov/pubmed/36480505 http://dx.doi.org/10.1371/journal.pone.0268361 |
work_keys_str_mv | AT sarhaddifatemeh acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT kazemikianoosh acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT azimiiman acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT caorui acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT nielavilenhannakaisa acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT axelinanna acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT liljebergpasi acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT rahmaniamirm acomprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT sarhaddifatemeh comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT kazemikianoosh comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT azimiiman comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT caorui comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT nielavilenhannakaisa comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT axelinanna comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT liljebergpasi comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability AT rahmaniamirm comprehensiveaccuracyassessmentofsamsungsmartwatchheartrateandheartratevariability |