Cargando…

Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values

This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW...

Descripción completa

Detalles Bibliográficos
Autores principales: Braambati, Dieimes, Monteiro, Renata de Castro, Coelho, Marcelo Santos, Soares, Adriana de Jesus, Frozoni, Marcos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Fundação Odontológica de Ribeirão Preto 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9733375/
https://www.ncbi.nlm.nih.gov/pubmed/36477962
http://dx.doi.org/10.1590/0103-6440202204855
_version_ 1784846361135415296
author Braambati, Dieimes
Monteiro, Renata de Castro
Coelho, Marcelo Santos
Soares, Adriana de Jesus
Frozoni, Marcos
author_facet Braambati, Dieimes
Monteiro, Renata de Castro
Coelho, Marcelo Santos
Soares, Adriana de Jesus
Frozoni, Marcos
author_sort Braambati, Dieimes
collection PubMed
description This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW) and 50° in clockwise (CW) at 350 RPM, and 150° CCW and 30° CW at 300 RPM. For the X-Smart Plus and VDW Silver the settings used were the ones in the motor library. For the iRoot, the motor was adjusted to the angles of the study. A customized optic target was attached to the contra-angle of the motor and the movements were recorded with a high-resolution camera (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) at 2,400 frames per second (FPS). The images were analyzed with the Vision Research software (Inc. Headquarters, Wayne, New Jersey, EUA). The following kinematic parameters were assessed: CCW angle, CW angle, speed (RPM) at both directions, and, standstill time at each change of directions. The Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis (method of Dunn) were used at a significant level of 5%. There was no statistically significant difference among the motors at the 150°/30° setting (P > .05); the iRoot was the least reliable at the 170°/50° setting for CCW angle, speed, and net angle parameters (P < 0.05). The standstill time of all motors in both directions was identical. None of the motors were able to reproduce faithfully the set movements. The iRoot motor presented a higher discrepancy when compared to X-Smart and VDW Silver.
format Online
Article
Text
id pubmed-9733375
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Fundação Odontológica de Ribeirão Preto
record_format MEDLINE/PubMed
spelling pubmed-97333752022-12-13 Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values Braambati, Dieimes Monteiro, Renata de Castro Coelho, Marcelo Santos Soares, Adriana de Jesus Frozoni, Marcos Braz Dent J Article This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW) and 50° in clockwise (CW) at 350 RPM, and 150° CCW and 30° CW at 300 RPM. For the X-Smart Plus and VDW Silver the settings used were the ones in the motor library. For the iRoot, the motor was adjusted to the angles of the study. A customized optic target was attached to the contra-angle of the motor and the movements were recorded with a high-resolution camera (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) at 2,400 frames per second (FPS). The images were analyzed with the Vision Research software (Inc. Headquarters, Wayne, New Jersey, EUA). The following kinematic parameters were assessed: CCW angle, CW angle, speed (RPM) at both directions, and, standstill time at each change of directions. The Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis (method of Dunn) were used at a significant level of 5%. There was no statistically significant difference among the motors at the 150°/30° setting (P > .05); the iRoot was the least reliable at the 170°/50° setting for CCW angle, speed, and net angle parameters (P < 0.05). The standstill time of all motors in both directions was identical. None of the motors were able to reproduce faithfully the set movements. The iRoot motor presented a higher discrepancy when compared to X-Smart and VDW Silver. Fundação Odontológica de Ribeirão Preto 2022-12-05 /pmc/articles/PMC9733375/ /pubmed/36477962 http://dx.doi.org/10.1590/0103-6440202204855 Text en https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Article
Braambati, Dieimes
Monteiro, Renata de Castro
Coelho, Marcelo Santos
Soares, Adriana de Jesus
Frozoni, Marcos
Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values
title Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values
title_full Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values
title_fullStr Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values
title_full_unstemmed Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values
title_short Reciprocating Kinematics of X-Smart Plus, VDW Silver and, iRoot Endodontic Motors: A Comparison Between Real and Set Values
title_sort reciprocating kinematics of x-smart plus, vdw silver and, iroot endodontic motors: a comparison between real and set values
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9733375/
https://www.ncbi.nlm.nih.gov/pubmed/36477962
http://dx.doi.org/10.1590/0103-6440202204855
work_keys_str_mv AT braambatidieimes reciprocatingkinematicsofxsmartplusvdwsilverandirootendodonticmotorsacomparisonbetweenrealandsetvalues
AT monteirorenatadecastro reciprocatingkinematicsofxsmartplusvdwsilverandirootendodonticmotorsacomparisonbetweenrealandsetvalues
AT coelhomarcelosantos reciprocatingkinematicsofxsmartplusvdwsilverandirootendodonticmotorsacomparisonbetweenrealandsetvalues
AT soaresadrianadejesus reciprocatingkinematicsofxsmartplusvdwsilverandirootendodonticmotorsacomparisonbetweenrealandsetvalues
AT frozonimarcos reciprocatingkinematicsofxsmartplusvdwsilverandirootendodonticmotorsacomparisonbetweenrealandsetvalues