Cargando…

Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development

This study proposed a modified three-stage auto-cascade refrigeration cycle (MTARC) operating with environmentally benign zeotropic mixture of R1234yf/R170/R14 at the refrigeration temperature level of − 80 °C. Compared with the conventional three-stage auto-cascade refrigeration cycle (CTARC), MTAR...

Descripción completa

Detalles Bibliográficos
Autores principales: Qin, Yanbin, Li, Nanxi, Zhang, Hua, Liu, Baolin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9734607/
https://www.ncbi.nlm.nih.gov/pubmed/36530955
http://dx.doi.org/10.1007/s10973-022-11721-w
_version_ 1784846611840499712
author Qin, Yanbin
Li, Nanxi
Zhang, Hua
Liu, Baolin
author_facet Qin, Yanbin
Li, Nanxi
Zhang, Hua
Liu, Baolin
author_sort Qin, Yanbin
collection PubMed
description This study proposed a modified three-stage auto-cascade refrigeration cycle (MTARC) operating with environmentally benign zeotropic mixture of R1234yf/R170/R14 at the refrigeration temperature level of − 80 °C. Compared with the conventional three-stage auto-cascade refrigeration cycle (CTARC), MTARC incorporates an additional pressure regulator between the condenser and separator to realize phase separation at a lower pressure and temperature. A comprehensive evaluation of energy and exergy performance of the two cycles was conducted theoretically. Under a typical working condition, the cooling capacity, COP and exergy efficiency of the MTARC are improved by 15.85%, 11.69% and 7.65% in comparison with the CTARC, respectively. In addition, a lower evaporating temperature was also obtained by the MTARC under the same operating condition. When the intermediate pressure drops from 2 to 1 MPa, the cooling capacity, COP and exergy efficiency are improved by 35.43%, 25.25% and 16.74%, respectively, for the MTARC, meanwhile the compressor outlet temperature increases 19.93 °C from 92.27 to 112.20 °C. Therefore, the selection of the intermediate pressure should be comprehensively considered to ensure a desirable cycle performance and a proper working condition for the compressor. The proposed modified cycle offers new pathways for designing innovative cryogenic refrigeration systems, thereby potentially improving the energy economy in a myriad of modern energy applications for sustainability concerns.
format Online
Article
Text
id pubmed-9734607
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-97346072022-12-12 Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development Qin, Yanbin Li, Nanxi Zhang, Hua Liu, Baolin J Therm Anal Calorim Article This study proposed a modified three-stage auto-cascade refrigeration cycle (MTARC) operating with environmentally benign zeotropic mixture of R1234yf/R170/R14 at the refrigeration temperature level of − 80 °C. Compared with the conventional three-stage auto-cascade refrigeration cycle (CTARC), MTARC incorporates an additional pressure regulator between the condenser and separator to realize phase separation at a lower pressure and temperature. A comprehensive evaluation of energy and exergy performance of the two cycles was conducted theoretically. Under a typical working condition, the cooling capacity, COP and exergy efficiency of the MTARC are improved by 15.85%, 11.69% and 7.65% in comparison with the CTARC, respectively. In addition, a lower evaporating temperature was also obtained by the MTARC under the same operating condition. When the intermediate pressure drops from 2 to 1 MPa, the cooling capacity, COP and exergy efficiency are improved by 35.43%, 25.25% and 16.74%, respectively, for the MTARC, meanwhile the compressor outlet temperature increases 19.93 °C from 92.27 to 112.20 °C. Therefore, the selection of the intermediate pressure should be comprehensively considered to ensure a desirable cycle performance and a proper working condition for the compressor. The proposed modified cycle offers new pathways for designing innovative cryogenic refrigeration systems, thereby potentially improving the energy economy in a myriad of modern energy applications for sustainability concerns. Springer International Publishing 2022-12-07 2023 /pmc/articles/PMC9734607/ /pubmed/36530955 http://dx.doi.org/10.1007/s10973-022-11721-w Text en © Akadémiai Kiadó, Budapest, Hungary 2022, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Article
Qin, Yanbin
Li, Nanxi
Zhang, Hua
Liu, Baolin
Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development
title Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development
title_full Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development
title_fullStr Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development
title_full_unstemmed Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development
title_short Energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-GWP refrigerants for sustainable development
title_sort energy and exergy analysis of a modified three-stage auto-cascade refrigeration cycle using low-gwp refrigerants for sustainable development
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9734607/
https://www.ncbi.nlm.nih.gov/pubmed/36530955
http://dx.doi.org/10.1007/s10973-022-11721-w
work_keys_str_mv AT qinyanbin energyandexergyanalysisofamodifiedthreestageautocascaderefrigerationcycleusinglowgwprefrigerantsforsustainabledevelopment
AT linanxi energyandexergyanalysisofamodifiedthreestageautocascaderefrigerationcycleusinglowgwprefrigerantsforsustainabledevelopment
AT zhanghua energyandexergyanalysisofamodifiedthreestageautocascaderefrigerationcycleusinglowgwprefrigerantsforsustainabledevelopment
AT liubaolin energyandexergyanalysisofamodifiedthreestageautocascaderefrigerationcycleusinglowgwprefrigerantsforsustainabledevelopment