Cargando…

Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank

Good solid-liquid mixing homogeneity and liquid level stability are necessary conditions for the preparation of high-quality composite materials. In this study, two rotor-stator agitators were utilized, including the cross-structure rotor-stator (CSRS) agitator and the half-cross structure rotor-sta...

Descripción completa

Detalles Bibliográficos
Autores principales: Yin, Cuicui, Zheng, Kaihong, He, Jiazhen, Xiong, Yongnan, Tian, Zhuo, Lin, Yingfei, Long, Danfeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736096/
https://www.ncbi.nlm.nih.gov/pubmed/36500064
http://dx.doi.org/10.3390/ma15238563
_version_ 1784846938014744576
author Yin, Cuicui
Zheng, Kaihong
He, Jiazhen
Xiong, Yongnan
Tian, Zhuo
Lin, Yingfei
Long, Danfeng
author_facet Yin, Cuicui
Zheng, Kaihong
He, Jiazhen
Xiong, Yongnan
Tian, Zhuo
Lin, Yingfei
Long, Danfeng
author_sort Yin, Cuicui
collection PubMed
description Good solid-liquid mixing homogeneity and liquid level stability are necessary conditions for the preparation of high-quality composite materials. In this study, two rotor-stator agitators were utilized, including the cross-structure rotor-stator (CSRS) agitator and the half-cross structure rotor-stator (HCSRS) agitator. The performances of the two types of rotor-stator agitators and the conventional A200 (an axial-flow agitator) and Rushton (a radial-flow agitator) in the solid-liquid mixing operations were compared through CFD modeling, including the homogeneity, power consumption and liquid level stability. The Eulerian–Eulerian multi-fluid model coupling with the RNG k–ε turbulence model were used to simulate the granular flow and the turbulence effects. When the optimum solid-liquid mixing homogeneity was achieved in both conventional agitators, further increasing stirring speed would worsen the homogeneity significantly, while the two rotor-stator agitators still achieving good mixing homogeneity at the stirring speed of 600 rpm. The CSRS agitator attained the minimum standard deviation of particle concentration σ of 0.15, which was 42% smaller than that achieved by the A200 agitators. Moreover, the average liquid level velocity corresponding to the minimum σ obtained by the CSRS agitator was 0.31 m/s, which was less than half of those of the other three mixers.
format Online
Article
Text
id pubmed-9736096
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97360962022-12-11 Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank Yin, Cuicui Zheng, Kaihong He, Jiazhen Xiong, Yongnan Tian, Zhuo Lin, Yingfei Long, Danfeng Materials (Basel) Article Good solid-liquid mixing homogeneity and liquid level stability are necessary conditions for the preparation of high-quality composite materials. In this study, two rotor-stator agitators were utilized, including the cross-structure rotor-stator (CSRS) agitator and the half-cross structure rotor-stator (HCSRS) agitator. The performances of the two types of rotor-stator agitators and the conventional A200 (an axial-flow agitator) and Rushton (a radial-flow agitator) in the solid-liquid mixing operations were compared through CFD modeling, including the homogeneity, power consumption and liquid level stability. The Eulerian–Eulerian multi-fluid model coupling with the RNG k–ε turbulence model were used to simulate the granular flow and the turbulence effects. When the optimum solid-liquid mixing homogeneity was achieved in both conventional agitators, further increasing stirring speed would worsen the homogeneity significantly, while the two rotor-stator agitators still achieving good mixing homogeneity at the stirring speed of 600 rpm. The CSRS agitator attained the minimum standard deviation of particle concentration σ of 0.15, which was 42% smaller than that achieved by the A200 agitators. Moreover, the average liquid level velocity corresponding to the minimum σ obtained by the CSRS agitator was 0.31 m/s, which was less than half of those of the other three mixers. MDPI 2022-12-01 /pmc/articles/PMC9736096/ /pubmed/36500064 http://dx.doi.org/10.3390/ma15238563 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yin, Cuicui
Zheng, Kaihong
He, Jiazhen
Xiong, Yongnan
Tian, Zhuo
Lin, Yingfei
Long, Danfeng
Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank
title Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank
title_full Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank
title_fullStr Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank
title_full_unstemmed Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank
title_short Turbulent CFD Simulation of Two Rotor-Stator Agitators for High Homogeneity and Liquid Level Stability in Stirred Tank
title_sort turbulent cfd simulation of two rotor-stator agitators for high homogeneity and liquid level stability in stirred tank
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736096/
https://www.ncbi.nlm.nih.gov/pubmed/36500064
http://dx.doi.org/10.3390/ma15238563
work_keys_str_mv AT yincuicui turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank
AT zhengkaihong turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank
AT hejiazhen turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank
AT xiongyongnan turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank
AT tianzhuo turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank
AT linyingfei turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank
AT longdanfeng turbulentcfdsimulationoftworotorstatoragitatorsforhighhomogeneityandliquidlevelstabilityinstirredtank