Cargando…

Analysis and Measurement of Differential-Mode Magnetic Noise in Mn-Zn Soft Ferrite Shield for Ultra-Sensitive Sensors

The magnetic noise generated by the ferrite magnetic shield affects the performance of ultra-sensitive atomic sensors. Differential measurement can effectively suppress the influence of common-mode (CM) magnetic noise, but the limit of suppression capability is not clear at present. In this paper, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Danyue, Fang, Xiujie, Lu, Jixi, Wang, Kun, Sun, Bowen, Gao, Yanan, Xu, Xueping, Han, Bangcheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736196/
https://www.ncbi.nlm.nih.gov/pubmed/36500199
http://dx.doi.org/10.3390/ma15238704
Descripción
Sumario:The magnetic noise generated by the ferrite magnetic shield affects the performance of ultra-sensitive atomic sensors. Differential measurement can effectively suppress the influence of common-mode (CM) magnetic noise, but the limit of suppression capability is not clear at present. In this paper, a finite element analysis model using power loss to calculate differential-mode (DM) magnetic noise under a ferrite magnetic shield is proposed. The experimental results confirm the feasibility of the model. An ultrahigh-sensitive magnetometer was built, the single channel magnetic noise measured and the differential-mode (DM) magnetic noise are 0.70 fT/Hz(1/2) and 0.10 fT/Hz(1/2) @30 Hz. The DM magnetic noise calculated by the proposed model is less than 5% different from the actual measured value. To effectively reduce DM magnetic noise, we analyze and optimize the structure parameters of the shield on the DM magnetic noise. When the outer diameter is fixed, the model is used to analyze the influence of the ratio of ferrite magnetic shielding thickness to outer diameter, the ratio of length to outer diameter, and the air gap between magnetic annuli on DM magnetic noise. The results show that the axial DM magnetic noise and radial DM magnetic noise reach the optimal values when the thickness to outer diameter ratio is 0.08 and 0.1. The ratio of length to outer diameter is negatively correlated with DM magnetic noise, and the air gap (0.1–1 mm) is independent of DM magnetic noise. The axial DM magnetic noise is less than that of radial DM magnetic noise. These results are useful for suppressing magnetic noise and breaking through the sensitivity of the magnetometer.