Cargando…

The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience

His bundle pacing (HBP) has several pitfalls, such as the inability to identify the His bundle and lack of capture at acceptable thresholds. The majority of data regarding HBP were obtained using a dedicated non-deflectable delivery system. This study aimed to evaluate the impact of cardiac chamber...

Descripción completa

Detalles Bibliográficos
Autores principales: Pestrea, Catalin, Cicala, Ecaterina, Ivascu, Madalina, Gherghina, Alexandra, Pintilie, Irina, Ortan, Florin, Pop, Dana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736366/
https://www.ncbi.nlm.nih.gov/pubmed/36498650
http://dx.doi.org/10.3390/jcm11237076
_version_ 1784847007770214400
author Pestrea, Catalin
Cicala, Ecaterina
Ivascu, Madalina
Gherghina, Alexandra
Pintilie, Irina
Ortan, Florin
Pop, Dana
author_facet Pestrea, Catalin
Cicala, Ecaterina
Ivascu, Madalina
Gherghina, Alexandra
Pintilie, Irina
Ortan, Florin
Pop, Dana
author_sort Pestrea, Catalin
collection PubMed
description His bundle pacing (HBP) has several pitfalls, such as the inability to identify the His bundle and lack of capture at acceptable thresholds. The majority of data regarding HBP were obtained using a dedicated non-deflectable delivery system. This study aimed to evaluate the impact of cardiac chamber dimensions on permanent HBP procedural outcomes when using this type of fixed-curve catheter. Seventy-two patients subjected to HBP from the 1st of January to the 31st of December 2021 at our institution were retrospectively reviewed. The baseline clinical characteristics and echocardiographic measurements of all the cardiac chambers were recorded, as well as procedural outcomes (HB electrogram identification and overall procedural success). During the procedure, the HB electrogram was recorded in 59 patients (81.9%) and successful permanent HBP was achieved in 33 patients, representing 45.8% of all the studied patients. Left atrial (LA) and right atrial (RA) volumes were significantly higher in patients without HB electrogram identification. Only LA and RA volumes were statistically associated with HB electrogram localization, while there was no significant association between the echocardiographic parameters and procedural success. LA volumes above 93 mL and RA volumes above 60 mL had an 8.81 times higher chance of failure to localize the HB electrogram compared with patients with lower volumes (p < 0.001). When considering non-deflectable delivery catheters for HBP, careful preprocedural echocardiographic analysis of the atrial volumes could help in the proper selection of implanting tools, thus optimizing the procedural outcomes and costs.
format Online
Article
Text
id pubmed-9736366
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97363662022-12-11 The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience Pestrea, Catalin Cicala, Ecaterina Ivascu, Madalina Gherghina, Alexandra Pintilie, Irina Ortan, Florin Pop, Dana J Clin Med Article His bundle pacing (HBP) has several pitfalls, such as the inability to identify the His bundle and lack of capture at acceptable thresholds. The majority of data regarding HBP were obtained using a dedicated non-deflectable delivery system. This study aimed to evaluate the impact of cardiac chamber dimensions on permanent HBP procedural outcomes when using this type of fixed-curve catheter. Seventy-two patients subjected to HBP from the 1st of January to the 31st of December 2021 at our institution were retrospectively reviewed. The baseline clinical characteristics and echocardiographic measurements of all the cardiac chambers were recorded, as well as procedural outcomes (HB electrogram identification and overall procedural success). During the procedure, the HB electrogram was recorded in 59 patients (81.9%) and successful permanent HBP was achieved in 33 patients, representing 45.8% of all the studied patients. Left atrial (LA) and right atrial (RA) volumes were significantly higher in patients without HB electrogram identification. Only LA and RA volumes were statistically associated with HB electrogram localization, while there was no significant association between the echocardiographic parameters and procedural success. LA volumes above 93 mL and RA volumes above 60 mL had an 8.81 times higher chance of failure to localize the HB electrogram compared with patients with lower volumes (p < 0.001). When considering non-deflectable delivery catheters for HBP, careful preprocedural echocardiographic analysis of the atrial volumes could help in the proper selection of implanting tools, thus optimizing the procedural outcomes and costs. MDPI 2022-11-29 /pmc/articles/PMC9736366/ /pubmed/36498650 http://dx.doi.org/10.3390/jcm11237076 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pestrea, Catalin
Cicala, Ecaterina
Ivascu, Madalina
Gherghina, Alexandra
Pintilie, Irina
Ortan, Florin
Pop, Dana
The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience
title The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience
title_full The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience
title_fullStr The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience
title_full_unstemmed The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience
title_short The Impact of Cardiac Chamber Volumes on Permanent His Bundle Pacing Procedural Outcomes—A Single Center Experience
title_sort impact of cardiac chamber volumes on permanent his bundle pacing procedural outcomes—a single center experience
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736366/
https://www.ncbi.nlm.nih.gov/pubmed/36498650
http://dx.doi.org/10.3390/jcm11237076
work_keys_str_mv AT pestreacatalin theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT cicalaecaterina theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT ivascumadalina theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT gherghinaalexandra theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT pintilieirina theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT ortanflorin theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT popdana theimpactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT pestreacatalin impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT cicalaecaterina impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT ivascumadalina impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT gherghinaalexandra impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT pintilieirina impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT ortanflorin impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience
AT popdana impactofcardiacchambervolumesonpermanenthisbundlepacingproceduraloutcomesasinglecenterexperience