Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism
Background: Posterior keratometry measurements are evolving features of the optical biometers. The differences between devices have bigger impact for the low astigmatism values. The majority of adults present the corneal astigmatism below 1.5 D. Objectives: To compare the total corneal astigmatism m...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736849/ https://www.ncbi.nlm.nih.gov/pubmed/36498495 http://dx.doi.org/10.3390/jcm11236921 |
_version_ | 1784847136653836288 |
---|---|
author | Muzyka-Woźniak, Maria Oleszko, Adam Grzybowski, Andrzej |
author_facet | Muzyka-Woźniak, Maria Oleszko, Adam Grzybowski, Andrzej |
author_sort | Muzyka-Woźniak, Maria |
collection | PubMed |
description | Background: Posterior keratometry measurements are evolving features of the optical biometers. The differences between devices have bigger impact for the low astigmatism values. The majority of adults present the corneal astigmatism below 1.5 D. Objectives: To compare the total corneal astigmatism measured with two different technologies in cataract patients with corneal astigmatism below 1.5 D. Material and Methods: Three automated exams were performed on each of the two devices: swept-source optical coherence tomography (SS-OCT) and Scheimpflug biometers. The anterior and total corneal astigmatism and power were analysed. Statistical comparisons were performed for within-subject standard deviation, repeatability, Bland–Altman and vector analysis. Results: Twenty-nine eyes of twenty-seven patients were included. The limits of agreement between anterior and total corneal astigmatism were narrower for the SS-OCT than for the Scheimpflug biometer (−0.16 to 0.29 D and −0.40 to 0.39 D, respectively). The >0.5 D difference between SS-OCT and Scheimpflug total astigmatism was noticed in 5 (17%) of cases. The difference between mean total keratometric power for both devices was statistically significant (0.2 D, p < 0.001). SS-OCT total corneal flat measurements had worse repeatability than Scheimpflug (p = 0.007). Conclusions: For the corneal astigmatism <1.5 D, the difference between anterior and total corneal astigmatism measured with SS-OCT was clinically not significant. The mean anterior and total keratometry values obtained with Scheimpflug and SS-OCT biometers are not interchangeable. |
format | Online Article Text |
id | pubmed-9736849 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97368492022-12-11 Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism Muzyka-Woźniak, Maria Oleszko, Adam Grzybowski, Andrzej J Clin Med Article Background: Posterior keratometry measurements are evolving features of the optical biometers. The differences between devices have bigger impact for the low astigmatism values. The majority of adults present the corneal astigmatism below 1.5 D. Objectives: To compare the total corneal astigmatism measured with two different technologies in cataract patients with corneal astigmatism below 1.5 D. Material and Methods: Three automated exams were performed on each of the two devices: swept-source optical coherence tomography (SS-OCT) and Scheimpflug biometers. The anterior and total corneal astigmatism and power were analysed. Statistical comparisons were performed for within-subject standard deviation, repeatability, Bland–Altman and vector analysis. Results: Twenty-nine eyes of twenty-seven patients were included. The limits of agreement between anterior and total corneal astigmatism were narrower for the SS-OCT than for the Scheimpflug biometer (−0.16 to 0.29 D and −0.40 to 0.39 D, respectively). The >0.5 D difference between SS-OCT and Scheimpflug total astigmatism was noticed in 5 (17%) of cases. The difference between mean total keratometric power for both devices was statistically significant (0.2 D, p < 0.001). SS-OCT total corneal flat measurements had worse repeatability than Scheimpflug (p = 0.007). Conclusions: For the corneal astigmatism <1.5 D, the difference between anterior and total corneal astigmatism measured with SS-OCT was clinically not significant. The mean anterior and total keratometry values obtained with Scheimpflug and SS-OCT biometers are not interchangeable. MDPI 2022-11-24 /pmc/articles/PMC9736849/ /pubmed/36498495 http://dx.doi.org/10.3390/jcm11236921 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Muzyka-Woźniak, Maria Oleszko, Adam Grzybowski, Andrzej Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism |
title | Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism |
title_full | Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism |
title_fullStr | Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism |
title_full_unstemmed | Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism |
title_short | Measurements of Anterior and Posterior Corneal Curvatures with OCT and Scheimpflug Biometers in Patients with Low Total Corneal Astigmatism |
title_sort | measurements of anterior and posterior corneal curvatures with oct and scheimpflug biometers in patients with low total corneal astigmatism |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9736849/ https://www.ncbi.nlm.nih.gov/pubmed/36498495 http://dx.doi.org/10.3390/jcm11236921 |
work_keys_str_mv | AT muzykawozniakmaria measurementsofanteriorandposteriorcornealcurvatureswithoctandscheimpflugbiometersinpatientswithlowtotalcornealastigmatism AT oleszkoadam measurementsofanteriorandposteriorcornealcurvatureswithoctandscheimpflugbiometersinpatientswithlowtotalcornealastigmatism AT grzybowskiandrzej measurementsofanteriorandposteriorcornealcurvatureswithoctandscheimpflugbiometersinpatientswithlowtotalcornealastigmatism |