A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix
A novel clinical workflow utilizing a direction modulated brachytherapy (DMBT) tandem applicator in combination with a patient-specific, 3D printed vaginal needle-track template for an advanced image-guided adaptive interstitial brachytherapy of the cervix. The proposed workflow has three main steps...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9738087/ https://www.ncbi.nlm.nih.gov/pubmed/36498563 http://dx.doi.org/10.3390/jcm11236989 |
_version_ | 1784847450114097152 |
---|---|
author | Sohn, James J. Polizzi, Mitchell Richeson, Dylan Gholami, Somayeh Das, Indra J. Song, William Y. |
author_facet | Sohn, James J. Polizzi, Mitchell Richeson, Dylan Gholami, Somayeh Das, Indra J. Song, William Y. |
author_sort | Sohn, James J. |
collection | PubMed |
description | A novel clinical workflow utilizing a direction modulated brachytherapy (DMBT) tandem applicator in combination with a patient-specific, 3D printed vaginal needle-track template for an advanced image-guided adaptive interstitial brachytherapy of the cervix. The proposed workflow has three main steps: (1) pre-treatment MRI, (2) an initial optimization of the needle positions based on the DMBT tandem positioning and patient anatomy, and a subsequent inverse optimization using the combined DMBT tandem and needles, and (3) rapid 3D printing. We retrospectively re-planned five patient cases for two scenarios; one plan with the DMBT tandem (T) and ovoids (O) with the original needle (ND) positions (DMBT + O + ND) and another with the DMBT T&O and spatially reoptimized needles (OptN) positions (DMBT + O + OptN). All retrospectively reoptimized plans have been compared to the original plan (OP) as well. The accuracy of 3D printing was verified through the image registration between the planning CT and the CT of the 3D-printed template. The average difference in D(2cc) for the bladder, rectum, and sigmoid between the OPs and DMBT + O + OptNs were −8.03 ± 4.04%, −18.67 ± 5.07%, and −26.53 ± 4.85%, respectively. In addition, these average differences between the DMBT + O + ND and DMBT + O + OptNs were −2.55 ± 1.87%, −10.70 ± 3.45%, and −22.03 ± 6.01%, respectively. The benefits could be significant for the patients in terms of target coverage and normal tissue sparing and increase the optimality over free-hand needle positioning. |
format | Online Article Text |
id | pubmed-9738087 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97380872022-12-11 A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix Sohn, James J. Polizzi, Mitchell Richeson, Dylan Gholami, Somayeh Das, Indra J. Song, William Y. J Clin Med Article A novel clinical workflow utilizing a direction modulated brachytherapy (DMBT) tandem applicator in combination with a patient-specific, 3D printed vaginal needle-track template for an advanced image-guided adaptive interstitial brachytherapy of the cervix. The proposed workflow has three main steps: (1) pre-treatment MRI, (2) an initial optimization of the needle positions based on the DMBT tandem positioning and patient anatomy, and a subsequent inverse optimization using the combined DMBT tandem and needles, and (3) rapid 3D printing. We retrospectively re-planned five patient cases for two scenarios; one plan with the DMBT tandem (T) and ovoids (O) with the original needle (ND) positions (DMBT + O + ND) and another with the DMBT T&O and spatially reoptimized needles (OptN) positions (DMBT + O + OptN). All retrospectively reoptimized plans have been compared to the original plan (OP) as well. The accuracy of 3D printing was verified through the image registration between the planning CT and the CT of the 3D-printed template. The average difference in D(2cc) for the bladder, rectum, and sigmoid between the OPs and DMBT + O + OptNs were −8.03 ± 4.04%, −18.67 ± 5.07%, and −26.53 ± 4.85%, respectively. In addition, these average differences between the DMBT + O + ND and DMBT + O + OptNs were −2.55 ± 1.87%, −10.70 ± 3.45%, and −22.03 ± 6.01%, respectively. The benefits could be significant for the patients in terms of target coverage and normal tissue sparing and increase the optimality over free-hand needle positioning. MDPI 2022-11-26 /pmc/articles/PMC9738087/ /pubmed/36498563 http://dx.doi.org/10.3390/jcm11236989 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sohn, James J. Polizzi, Mitchell Richeson, Dylan Gholami, Somayeh Das, Indra J. Song, William Y. A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix |
title | A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix |
title_full | A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix |
title_fullStr | A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix |
title_full_unstemmed | A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix |
title_short | A Novel Workflow with a Customizable 3D Printed Vaginal Template and a Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Adaptive Interstitial Brachytherapy of the Cervix |
title_sort | novel workflow with a customizable 3d printed vaginal template and a direction modulated brachytherapy (dmbt) tandem applicator for adaptive interstitial brachytherapy of the cervix |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9738087/ https://www.ncbi.nlm.nih.gov/pubmed/36498563 http://dx.doi.org/10.3390/jcm11236989 |
work_keys_str_mv | AT sohnjamesj anovelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT polizzimitchell anovelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT richesondylan anovelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT gholamisomayeh anovelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT dasindraj anovelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT songwilliamy anovelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT sohnjamesj novelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT polizzimitchell novelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT richesondylan novelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT gholamisomayeh novelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT dasindraj novelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix AT songwilliamy novelworkflowwithacustomizable3dprintedvaginaltemplateandadirectionmodulatedbrachytherapydmbttandemapplicatorforadaptiveinterstitialbrachytherapyofthecervix |