Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study
Monitoring of sports practice has become an almost essential tool in high-level professional training. The knowledge of the exact movements performed by an athlete provides a great advantage over conventional training, since the best performance can be theoretically known in advance and the trainer...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9739086/ https://www.ncbi.nlm.nih.gov/pubmed/36502114 http://dx.doi.org/10.3390/s22239408 |
_version_ | 1784847715704766464 |
---|---|
author | Navarro-Iribarne, Juan Francisco Moreno-Salinas, David Sánchez-Moreno, José |
author_facet | Navarro-Iribarne, Juan Francisco Moreno-Salinas, David Sánchez-Moreno, José |
author_sort | Navarro-Iribarne, Juan Francisco |
collection | PubMed |
description | Monitoring of sports practice has become an almost essential tool in high-level professional training. The knowledge of the exact movements performed by an athlete provides a great advantage over conventional training, since the best performance can be theoretically known in advance and the trainer will expect the real athlete’s movements to approximate it. Following this trend, this article deals with the design and development of a low-cost wearable biofeedback system for the measurement and representation of kinematic parameters in 3D. To capture the athlete’s movements, an inertial measurement unit (IMU) is used, whose data are processed in an microcontroller-based architecture. The kinematic parameters of the athlete’s movement are sent via Bluetooth to a smart phone, where they are displayed graphically. Experimental examples show the effectiveness of the device developed and illustrate the key results derived. |
format | Online Article Text |
id | pubmed-9739086 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97390862022-12-11 Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study Navarro-Iribarne, Juan Francisco Moreno-Salinas, David Sánchez-Moreno, José Sensors (Basel) Article Monitoring of sports practice has become an almost essential tool in high-level professional training. The knowledge of the exact movements performed by an athlete provides a great advantage over conventional training, since the best performance can be theoretically known in advance and the trainer will expect the real athlete’s movements to approximate it. Following this trend, this article deals with the design and development of a low-cost wearable biofeedback system for the measurement and representation of kinematic parameters in 3D. To capture the athlete’s movements, an inertial measurement unit (IMU) is used, whose data are processed in an microcontroller-based architecture. The kinematic parameters of the athlete’s movement are sent via Bluetooth to a smart phone, where they are displayed graphically. Experimental examples show the effectiveness of the device developed and illustrate the key results derived. MDPI 2022-12-02 /pmc/articles/PMC9739086/ /pubmed/36502114 http://dx.doi.org/10.3390/s22239408 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Navarro-Iribarne, Juan Francisco Moreno-Salinas, David Sánchez-Moreno, José Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study |
title | Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study |
title_full | Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study |
title_fullStr | Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study |
title_full_unstemmed | Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study |
title_short | Low-Cost Portable System for Measurement and Representation of 3D Kinematic Parameters in Sport Monitoring: Discus Throwing as a Case Study |
title_sort | low-cost portable system for measurement and representation of 3d kinematic parameters in sport monitoring: discus throwing as a case study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9739086/ https://www.ncbi.nlm.nih.gov/pubmed/36502114 http://dx.doi.org/10.3390/s22239408 |
work_keys_str_mv | AT navarroiribarnejuanfrancisco lowcostportablesystemformeasurementandrepresentationof3dkinematicparametersinsportmonitoringdiscusthrowingasacasestudy AT morenosalinasdavid lowcostportablesystemformeasurementandrepresentationof3dkinematicparametersinsportmonitoringdiscusthrowingasacasestudy AT sanchezmorenojose lowcostportablesystemformeasurementandrepresentationof3dkinematicparametersinsportmonitoringdiscusthrowingasacasestudy |