Cargando…
Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment
Diabetes is a heterogeneous group of diseases that share a common trait of elevated blood glucose levels. Insulin lowers this level by promoting glucose utilization, thus avoiding short- and long-term organ damage due to the elevated blood glucose level. A patient with diabetes uses an insulin pump...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9739839/ https://www.ncbi.nlm.nih.gov/pubmed/36502149 http://dx.doi.org/10.3390/s22239445 |
_version_ | 1784847908072325120 |
---|---|
author | Ubl, Martin Koutny, Tomas Della Cioppa, Antonio De Falco, Ivanoe Tarantino, Ernesto Scafuri, Umberto |
author_facet | Ubl, Martin Koutny, Tomas Della Cioppa, Antonio De Falco, Ivanoe Tarantino, Ernesto Scafuri, Umberto |
author_sort | Ubl, Martin |
collection | PubMed |
description | Diabetes is a heterogeneous group of diseases that share a common trait of elevated blood glucose levels. Insulin lowers this level by promoting glucose utilization, thus avoiding short- and long-term organ damage due to the elevated blood glucose level. A patient with diabetes uses an insulin pump to dose insulin. The pump uses a controller to compute and dose the correct amount of insulin to keep blood glucose levels in a safe range. Insulin-pump controller development is an ongoing process aiming at fully closed-loop control. Controllers entering the market must be evaluated for safety. We propose an evaluation method that exploits an FDA-approved diabetic patient simulator. The method evaluates a Cartesian product of individual insulin-pump parameters with a fine degree of granularity. As this is a computationally intensive task, the simulator executes on a distributed cluster. We identify safe and risky combinations of insulin-pump parameter settings by applying the binomial model and decision tree to this product. As a result, we obtain a tool for insulin-pump settings and controller safety assessment. In this paper, we demonstrate the tool with the Low-Glucose Suspend and OpenAPS controllers. For average ± standard deviation, LGS and OpenAPS exhibited 1.7 ± 0.6% and 3.2 ± 1.8% of local extrema (i.e., good insulin-pump settings) out of all the entire Cartesian products, respectively. A continuous region around the best-discovered settings (i.e., the global extremum) of the insulin-pump settings spread across 4.0 ± 1.1% and 4.1 ± 1.3% of the Cartesian products, respectively. |
format | Online Article Text |
id | pubmed-9739839 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97398392022-12-11 Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment Ubl, Martin Koutny, Tomas Della Cioppa, Antonio De Falco, Ivanoe Tarantino, Ernesto Scafuri, Umberto Sensors (Basel) Article Diabetes is a heterogeneous group of diseases that share a common trait of elevated blood glucose levels. Insulin lowers this level by promoting glucose utilization, thus avoiding short- and long-term organ damage due to the elevated blood glucose level. A patient with diabetes uses an insulin pump to dose insulin. The pump uses a controller to compute and dose the correct amount of insulin to keep blood glucose levels in a safe range. Insulin-pump controller development is an ongoing process aiming at fully closed-loop control. Controllers entering the market must be evaluated for safety. We propose an evaluation method that exploits an FDA-approved diabetic patient simulator. The method evaluates a Cartesian product of individual insulin-pump parameters with a fine degree of granularity. As this is a computationally intensive task, the simulator executes on a distributed cluster. We identify safe and risky combinations of insulin-pump parameter settings by applying the binomial model and decision tree to this product. As a result, we obtain a tool for insulin-pump settings and controller safety assessment. In this paper, we demonstrate the tool with the Low-Glucose Suspend and OpenAPS controllers. For average ± standard deviation, LGS and OpenAPS exhibited 1.7 ± 0.6% and 3.2 ± 1.8% of local extrema (i.e., good insulin-pump settings) out of all the entire Cartesian products, respectively. A continuous region around the best-discovered settings (i.e., the global extremum) of the insulin-pump settings spread across 4.0 ± 1.1% and 4.1 ± 1.3% of the Cartesian products, respectively. MDPI 2022-12-02 /pmc/articles/PMC9739839/ /pubmed/36502149 http://dx.doi.org/10.3390/s22239445 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ubl, Martin Koutny, Tomas Della Cioppa, Antonio De Falco, Ivanoe Tarantino, Ernesto Scafuri, Umberto Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment |
title | Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment |
title_full | Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment |
title_fullStr | Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment |
title_full_unstemmed | Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment |
title_short | Distributed Assessment of Virtual Insulin-Pump Settings Using SmartCGMS and DMMS.R for Diabetes Treatment |
title_sort | distributed assessment of virtual insulin-pump settings using smartcgms and dmms.r for diabetes treatment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9739839/ https://www.ncbi.nlm.nih.gov/pubmed/36502149 http://dx.doi.org/10.3390/s22239445 |
work_keys_str_mv | AT ublmartin distributedassessmentofvirtualinsulinpumpsettingsusingsmartcgmsanddmmsrfordiabetestreatment AT koutnytomas distributedassessmentofvirtualinsulinpumpsettingsusingsmartcgmsanddmmsrfordiabetestreatment AT dellacioppaantonio distributedassessmentofvirtualinsulinpumpsettingsusingsmartcgmsanddmmsrfordiabetestreatment AT defalcoivanoe distributedassessmentofvirtualinsulinpumpsettingsusingsmartcgmsanddmmsrfordiabetestreatment AT tarantinoernesto distributedassessmentofvirtualinsulinpumpsettingsusingsmartcgmsanddmmsrfordiabetestreatment AT scafuriumberto distributedassessmentofvirtualinsulinpumpsettingsusingsmartcgmsanddmmsrfordiabetestreatment |