Cargando…
A Pilot Study on the Inter-Operator Reproducibility of a Wireless Sensors-Based System for Quantifying Gait Asymmetries in Horses
Repeatability and reproducibility of any measuring system must be evaluated to assess possible limitations for its use. The objective of this study was to establish the repeatability and the inter-operator reproducibility of a sensors-based system (EQUISYM(®)) for quantifying gait asymmetries in hor...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9740227/ https://www.ncbi.nlm.nih.gov/pubmed/36502233 http://dx.doi.org/10.3390/s22239533 |
Sumario: | Repeatability and reproducibility of any measuring system must be evaluated to assess possible limitations for its use. The objective of this study was to establish the repeatability and the inter-operator reproducibility of a sensors-based system (EQUISYM(®)) for quantifying gait asymmetries in horses.. Seven wireless IMUs were placed on the head, the withers, the pelvis, and the 4 cannon bones on three horses, by four different operators, four times on each horse, which led to a total of 48 repetitions randomly assigned. Data were collected along three consecutive days and analysed to calculate total variance, standard deviation and the variance attributable to the operator on multiple asymmetry variables. Maximal percentage of variance due to the operator (calculated out of the total variance) was 5.3% and was related to the sensor placed on the head. The results suggest a good reproducibility of IMU-based gait analysis systems for different operators repositioning the system and repeating the same measurements at a succession of time intervals. Future studies will be useful to confirm that inter-operator reproducibility remains valid in larger groups and on horses with different degrees of locomotor asymmetry. |
---|