Cargando…

Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry

A simple, rapid, sensitive, accurate, and automatic graphite furnace atomic absorption spectrometry (GFAAS) method for detecting Cd and Pb in cereals is presented. This method enables the simultaneous determination of Cd and Pb in cereals with a pre-treatment method of diluted acid extraction and a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Yanxiang, Wang, Songxue, Cui, Weibing, Tian, Wei, Zhang, Jieqiong, Chen, Xi, Zhou, Minghui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9740317/
https://www.ncbi.nlm.nih.gov/pubmed/36500663
http://dx.doi.org/10.3390/molecules27238571
_version_ 1784848031161516032
author Wu, Yanxiang
Wang, Songxue
Cui, Weibing
Tian, Wei
Zhang, Jieqiong
Chen, Xi
Zhou, Minghui
author_facet Wu, Yanxiang
Wang, Songxue
Cui, Weibing
Tian, Wei
Zhang, Jieqiong
Chen, Xi
Zhou, Minghui
author_sort Wu, Yanxiang
collection PubMed
description A simple, rapid, sensitive, accurate, and automatic graphite furnace atomic absorption spectrometry (GFAAS) method for detecting Cd and Pb in cereals is presented. This method enables the simultaneous determination of Cd and Pb in cereals with a pre-treatment method of diluted acid extraction and a high-performance lead–cadmium composite hollow-cathode lamp (LCC-HCL), and it realizes automatic determination from sample weighing to result output through an automatic diluted acid extraction system. Under the optimization, Pb and Cd in cereals were simultaneously and automatically detected in up to 240 measurements in 8 h. The LOD and LOQ of this method were 0.012 and 0.040 mg·kg(−1) for Pb, and 0.0014 and 0.0047 mg·kg(−1) for Cd, respectively. The results of the four certified reference materials were satisfied; there was no significant difference compared with the ICP-MS method according to a t-test, and the RSDs were less than 5% for Cd and Pb. The recoveries of naturally contaminated samples compared with the ICP-MS method were favorable, with 80–110% in eight laboratories. The developed method is rapid, low-cost, and highly automated and may be a good choice for grain quality discrimination and rapid analysis of Cd and Pb in different institutions.
format Online
Article
Text
id pubmed-9740317
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97403172022-12-11 Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry Wu, Yanxiang Wang, Songxue Cui, Weibing Tian, Wei Zhang, Jieqiong Chen, Xi Zhou, Minghui Molecules Article A simple, rapid, sensitive, accurate, and automatic graphite furnace atomic absorption spectrometry (GFAAS) method for detecting Cd and Pb in cereals is presented. This method enables the simultaneous determination of Cd and Pb in cereals with a pre-treatment method of diluted acid extraction and a high-performance lead–cadmium composite hollow-cathode lamp (LCC-HCL), and it realizes automatic determination from sample weighing to result output through an automatic diluted acid extraction system. Under the optimization, Pb and Cd in cereals were simultaneously and automatically detected in up to 240 measurements in 8 h. The LOD and LOQ of this method were 0.012 and 0.040 mg·kg(−1) for Pb, and 0.0014 and 0.0047 mg·kg(−1) for Cd, respectively. The results of the four certified reference materials were satisfied; there was no significant difference compared with the ICP-MS method according to a t-test, and the RSDs were less than 5% for Cd and Pb. The recoveries of naturally contaminated samples compared with the ICP-MS method were favorable, with 80–110% in eight laboratories. The developed method is rapid, low-cost, and highly automated and may be a good choice for grain quality discrimination and rapid analysis of Cd and Pb in different institutions. MDPI 2022-12-05 /pmc/articles/PMC9740317/ /pubmed/36500663 http://dx.doi.org/10.3390/molecules27238571 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wu, Yanxiang
Wang, Songxue
Cui, Weibing
Tian, Wei
Zhang, Jieqiong
Chen, Xi
Zhou, Minghui
Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry
title Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry
title_full Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry
title_fullStr Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry
title_full_unstemmed Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry
title_short Rapid, Simultaneous, and Automatic Determination of Lead and Cadmium in Cereals with a New High Performance Composite Hollow Cathode Lamp Coupled to Graphite Furnace Atomic Absorption Spectrometry
title_sort rapid, simultaneous, and automatic determination of lead and cadmium in cereals with a new high performance composite hollow cathode lamp coupled to graphite furnace atomic absorption spectrometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9740317/
https://www.ncbi.nlm.nih.gov/pubmed/36500663
http://dx.doi.org/10.3390/molecules27238571
work_keys_str_mv AT wuyanxiang rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry
AT wangsongxue rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry
AT cuiweibing rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry
AT tianwei rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry
AT zhangjieqiong rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry
AT chenxi rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry
AT zhouminghui rapidsimultaneousandautomaticdeterminationofleadandcadmiumincerealswithanewhighperformancecompositehollowcathodelampcoupledtographitefurnaceatomicabsorptionspectrometry