Cargando…

Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions

Allergic reactions to COVID-19 vaccine components are rare but should be considered. Polyethylene glycol (PEG) is responsible for anaphylaxis in mRNA vaccines. Skin tests have been used in the allergological work-up programs for COVID-19 vaccine evaluation. However, the reproducibility of the skin p...

Descripción completa

Detalles Bibliográficos
Autores principales: Vespa, Simone, Del Biondo, Pietro, Simeone, Pasquale, Cavallucci, Enrico, Catitti, Giulia, Auciello, Raffaella, De Bellis, Domenico, Altomare, Isotta, Pierdomenico, Laura, Canonico, Barbara, Cicalini, Ilaria, Angilletta, Ilaria, Del Boccio, Piero, Pieragostino, Damiana, Santilli, Francesca, Urbani, Andrea, De Laurenzi, Vincenzo, Stuppia, Liborio, Lanuti, Paola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9740962/
https://www.ncbi.nlm.nih.gov/pubmed/36498922
http://dx.doi.org/10.3390/ijms232314592
_version_ 1784848198092718080
author Vespa, Simone
Del Biondo, Pietro
Simeone, Pasquale
Cavallucci, Enrico
Catitti, Giulia
Auciello, Raffaella
De Bellis, Domenico
Altomare, Isotta
Pierdomenico, Laura
Canonico, Barbara
Cicalini, Ilaria
Angilletta, Ilaria
Del Boccio, Piero
Pieragostino, Damiana
Santilli, Francesca
Urbani, Andrea
De Laurenzi, Vincenzo
Stuppia, Liborio
Lanuti, Paola
author_facet Vespa, Simone
Del Biondo, Pietro
Simeone, Pasquale
Cavallucci, Enrico
Catitti, Giulia
Auciello, Raffaella
De Bellis, Domenico
Altomare, Isotta
Pierdomenico, Laura
Canonico, Barbara
Cicalini, Ilaria
Angilletta, Ilaria
Del Boccio, Piero
Pieragostino, Damiana
Santilli, Francesca
Urbani, Andrea
De Laurenzi, Vincenzo
Stuppia, Liborio
Lanuti, Paola
author_sort Vespa, Simone
collection PubMed
description Allergic reactions to COVID-19 vaccine components are rare but should be considered. Polyethylene glycol (PEG) is responsible for anaphylaxis in mRNA vaccines. Skin tests have been used in the allergological work-up programs for COVID-19 vaccine evaluation. However, the reproducibility of the skin prick test is time-dependent and the reactivity declines over time. Therefore, we combined the administration of the skin tests with the basophil activation test (BAT) using PEG2000, PEG4000 and DMG-PEG2000, where the BAT was considered positive when the percentage of activated basophils was higher than 6%, 5% and 6.5%, for PEG 4000, PEG2000 and DMG-PEG2000, respectively. To this end, among the subjects that underwent allergy counseling at the Allergy Unit of our Institution during the 2020/2021 vaccination campaign, 13 patients had a suggested medical history of PEG/drug hypersensitivity and were enrolled together with 10 healthy donors. Among the enrolled patients 2 out of 13 tested patients were positive to the skin test. The BAT was negative in terms of the percentages of activated basophils in all analyzed samples, but the stimulation index (SI) was higher than 2.5 in 4 out of 13 patients. These data evidenced that, when the SI is higher than 2.5, even in the absence of positivity to BAT, the BAT to PEG may be a useful tool to be coupled to skin tests to evidence even low-grade reactions.
format Online
Article
Text
id pubmed-9740962
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-97409622022-12-11 Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions Vespa, Simone Del Biondo, Pietro Simeone, Pasquale Cavallucci, Enrico Catitti, Giulia Auciello, Raffaella De Bellis, Domenico Altomare, Isotta Pierdomenico, Laura Canonico, Barbara Cicalini, Ilaria Angilletta, Ilaria Del Boccio, Piero Pieragostino, Damiana Santilli, Francesca Urbani, Andrea De Laurenzi, Vincenzo Stuppia, Liborio Lanuti, Paola Int J Mol Sci Communication Allergic reactions to COVID-19 vaccine components are rare but should be considered. Polyethylene glycol (PEG) is responsible for anaphylaxis in mRNA vaccines. Skin tests have been used in the allergological work-up programs for COVID-19 vaccine evaluation. However, the reproducibility of the skin prick test is time-dependent and the reactivity declines over time. Therefore, we combined the administration of the skin tests with the basophil activation test (BAT) using PEG2000, PEG4000 and DMG-PEG2000, where the BAT was considered positive when the percentage of activated basophils was higher than 6%, 5% and 6.5%, for PEG 4000, PEG2000 and DMG-PEG2000, respectively. To this end, among the subjects that underwent allergy counseling at the Allergy Unit of our Institution during the 2020/2021 vaccination campaign, 13 patients had a suggested medical history of PEG/drug hypersensitivity and were enrolled together with 10 healthy donors. Among the enrolled patients 2 out of 13 tested patients were positive to the skin test. The BAT was negative in terms of the percentages of activated basophils in all analyzed samples, but the stimulation index (SI) was higher than 2.5 in 4 out of 13 patients. These data evidenced that, when the SI is higher than 2.5, even in the absence of positivity to BAT, the BAT to PEG may be a useful tool to be coupled to skin tests to evidence even low-grade reactions. MDPI 2022-11-23 /pmc/articles/PMC9740962/ /pubmed/36498922 http://dx.doi.org/10.3390/ijms232314592 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Vespa, Simone
Del Biondo, Pietro
Simeone, Pasquale
Cavallucci, Enrico
Catitti, Giulia
Auciello, Raffaella
De Bellis, Domenico
Altomare, Isotta
Pierdomenico, Laura
Canonico, Barbara
Cicalini, Ilaria
Angilletta, Ilaria
Del Boccio, Piero
Pieragostino, Damiana
Santilli, Francesca
Urbani, Andrea
De Laurenzi, Vincenzo
Stuppia, Liborio
Lanuti, Paola
Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions
title Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions
title_full Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions
title_fullStr Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions
title_full_unstemmed Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions
title_short Basophil Activation Test with Different Polyethylene Glycols in Patients with Suspected PEG Hypersensitivity Reactions
title_sort basophil activation test with different polyethylene glycols in patients with suspected peg hypersensitivity reactions
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9740962/
https://www.ncbi.nlm.nih.gov/pubmed/36498922
http://dx.doi.org/10.3390/ijms232314592
work_keys_str_mv AT vespasimone basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT delbiondopietro basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT simeonepasquale basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT cavalluccienrico basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT catittigiulia basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT aucielloraffaella basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT debellisdomenico basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT altomareisotta basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT pierdomenicolaura basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT canonicobarbara basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT cicaliniilaria basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT angillettailaria basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT delbocciopiero basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT pieragostinodamiana basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT santillifrancesca basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT urbaniandrea basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT delaurenzivincenzo basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT stuppialiborio basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions
AT lanutipaola basophilactivationtestwithdifferentpolyethyleneglycolsinpatientswithsuspectedpeghypersensitivityreactions