Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis
Objective: This study aimed to compare the surgical outcomes between robotic multi-site myomectomy (RMSM) and robotic single-site myomectomy (RSSM), using the da Vinci(®) SP surgical system and perform propensity score matching analysis to ensure inter-group comparability. Methods: This retrospectiv...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741369/ https://www.ncbi.nlm.nih.gov/pubmed/36498480 http://dx.doi.org/10.3390/jcm11236905 |
_version_ | 1784848302840217600 |
---|---|
author | Kim, Jong Mi Lee, Yoon Hee Chong, Gun Oh Lee, Sae Rom Hong, Dae Gy |
author_facet | Kim, Jong Mi Lee, Yoon Hee Chong, Gun Oh Lee, Sae Rom Hong, Dae Gy |
author_sort | Kim, Jong Mi |
collection | PubMed |
description | Objective: This study aimed to compare the surgical outcomes between robotic multi-site myomectomy (RMSM) and robotic single-site myomectomy (RSSM), using the da Vinci(®) SP surgical system and perform propensity score matching analysis to ensure inter-group comparability. Methods: This retrospective study included 105 patients who underwent either three-incision RMSM or RSSM using the da Vinci(®) SP surgical system. We retrospectively reviewed and compared surgical outcomes using 1:1 propensity score matching. Results: After 1:1 propensity score matching, there were no differences in the total operation time and estimated blood loss between the groups. The docking time (p < 0.0001) and duration of hospital stay (p = 0.0001) were significantly shorter in the RSSM group than in the RMSM group. Conclusions: The surgical outcomes of RSSM were comparable to those of RMSM. Moreover, compared to RMSM, RSSM using the da Vinci(®) SP surgical system has shorter docking and morcellation times, and duration of hospital stay. |
format | Online Article Text |
id | pubmed-9741369 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97413692022-12-11 Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis Kim, Jong Mi Lee, Yoon Hee Chong, Gun Oh Lee, Sae Rom Hong, Dae Gy J Clin Med Article Objective: This study aimed to compare the surgical outcomes between robotic multi-site myomectomy (RMSM) and robotic single-site myomectomy (RSSM), using the da Vinci(®) SP surgical system and perform propensity score matching analysis to ensure inter-group comparability. Methods: This retrospective study included 105 patients who underwent either three-incision RMSM or RSSM using the da Vinci(®) SP surgical system. We retrospectively reviewed and compared surgical outcomes using 1:1 propensity score matching. Results: After 1:1 propensity score matching, there were no differences in the total operation time and estimated blood loss between the groups. The docking time (p < 0.0001) and duration of hospital stay (p = 0.0001) were significantly shorter in the RSSM group than in the RMSM group. Conclusions: The surgical outcomes of RSSM were comparable to those of RMSM. Moreover, compared to RMSM, RSSM using the da Vinci(®) SP surgical system has shorter docking and morcellation times, and duration of hospital stay. MDPI 2022-11-23 /pmc/articles/PMC9741369/ /pubmed/36498480 http://dx.doi.org/10.3390/jcm11236905 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kim, Jong Mi Lee, Yoon Hee Chong, Gun Oh Lee, Sae Rom Hong, Dae Gy Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis |
title | Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis |
title_full | Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis |
title_fullStr | Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis |
title_full_unstemmed | Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis |
title_short | Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci(®) SP Surgical System: A Propensity Score Matching Analysis |
title_sort | comparison of multi- and single-site robotic myomectomy using the da vinci(®) sp surgical system: a propensity score matching analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741369/ https://www.ncbi.nlm.nih.gov/pubmed/36498480 http://dx.doi.org/10.3390/jcm11236905 |
work_keys_str_mv | AT kimjongmi comparisonofmultiandsinglesiteroboticmyomectomyusingthedavincispsurgicalsystemapropensityscorematchinganalysis AT leeyoonhee comparisonofmultiandsinglesiteroboticmyomectomyusingthedavincispsurgicalsystemapropensityscorematchinganalysis AT chonggunoh comparisonofmultiandsinglesiteroboticmyomectomyusingthedavincispsurgicalsystemapropensityscorematchinganalysis AT leesaerom comparisonofmultiandsinglesiteroboticmyomectomyusingthedavincispsurgicalsystemapropensityscorematchinganalysis AT hongdaegy comparisonofmultiandsinglesiteroboticmyomectomyusingthedavincispsurgicalsystemapropensityscorematchinganalysis |