Cargando…
Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments
The paper presents experimental data that show the possible application of a piezo actuator in the role of calibration standard that can serve as an alternative route to currently available methods like gauge blocks or flick standards. First, the experimental setups for interferometric and roundness...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741474/ https://www.ncbi.nlm.nih.gov/pubmed/36502014 http://dx.doi.org/10.3390/s22239312 |
_version_ | 1784848329425813504 |
---|---|
author | Trych-Wildner, Anna Wildner, Krzysztof Sosinowski, Piotr |
author_facet | Trych-Wildner, Anna Wildner, Krzysztof Sosinowski, Piotr |
author_sort | Trych-Wildner, Anna |
collection | PubMed |
description | The paper presents experimental data that show the possible application of a piezo actuator in the role of calibration standard that can serve as an alternative route to currently available methods like gauge blocks or flick standards. First, the experimental setups for interferometric and roundness instruments measurements were described. Next, the experiments using an interferometer for calibration of the piezo actuator were shown. Finally, the application of a piezo actuator to calibrate the roundness instrument, to state the correction factor for the roundness probe, and to relate it to the unit of metre, assuring the traceability of future measurements was performed. Detailed procedures of simulating grooves and then processing the data were described and the calibration curve was obtained using regression analysis. The estimation of uncertainty provided by different factors during the measurements was given to fulfil as closely as possible real calibration procedures taken up in the measurement laboratories. Finally, the limitations of the presented procedures were presented and discussed. |
format | Online Article Text |
id | pubmed-9741474 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-97414742022-12-11 Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments Trych-Wildner, Anna Wildner, Krzysztof Sosinowski, Piotr Sensors (Basel) Article The paper presents experimental data that show the possible application of a piezo actuator in the role of calibration standard that can serve as an alternative route to currently available methods like gauge blocks or flick standards. First, the experimental setups for interferometric and roundness instruments measurements were described. Next, the experiments using an interferometer for calibration of the piezo actuator were shown. Finally, the application of a piezo actuator to calibrate the roundness instrument, to state the correction factor for the roundness probe, and to relate it to the unit of metre, assuring the traceability of future measurements was performed. Detailed procedures of simulating grooves and then processing the data were described and the calibration curve was obtained using regression analysis. The estimation of uncertainty provided by different factors during the measurements was given to fulfil as closely as possible real calibration procedures taken up in the measurement laboratories. Finally, the limitations of the presented procedures were presented and discussed. MDPI 2022-11-29 /pmc/articles/PMC9741474/ /pubmed/36502014 http://dx.doi.org/10.3390/s22239312 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Trych-Wildner, Anna Wildner, Krzysztof Sosinowski, Piotr Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments |
title | Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments |
title_full | Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments |
title_fullStr | Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments |
title_full_unstemmed | Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments |
title_short | Feasibility Study of a Piezo Actuator as a Potential Standard in Calibration for Roundness Instruments |
title_sort | feasibility study of a piezo actuator as a potential standard in calibration for roundness instruments |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741474/ https://www.ncbi.nlm.nih.gov/pubmed/36502014 http://dx.doi.org/10.3390/s22239312 |
work_keys_str_mv | AT trychwildneranna feasibilitystudyofapiezoactuatorasapotentialstandardincalibrationforroundnessinstruments AT wildnerkrzysztof feasibilitystudyofapiezoactuatorasapotentialstandardincalibrationforroundnessinstruments AT sosinowskipiotr feasibilitystudyofapiezoactuatorasapotentialstandardincalibrationforroundnessinstruments |