Cargando…

Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study

BACKGROUND: The subarachnoid space width (SASw) is part of crucial neuroimaging criteria for the diagnosis of subarachnoid space enlargement in infants. In addition to indicating the presence of these diseases, SASw can be used to assess their severity. Therefore, it is important to be able to measu...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Lei, Liu, Heng, Ren, Zhuanqin, Wang, Xiaohu, Meng, Xiaoli, Wei, Xiaocheng, Yang, Jian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Whioce Publishing Pte. Ltd. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741930/
https://www.ncbi.nlm.nih.gov/pubmed/36518203
_version_ 1784848421923848192
author Zhang, Lei
Liu, Heng
Ren, Zhuanqin
Wang, Xiaohu
Meng, Xiaoli
Wei, Xiaocheng
Yang, Jian
author_facet Zhang, Lei
Liu, Heng
Ren, Zhuanqin
Wang, Xiaohu
Meng, Xiaoli
Wei, Xiaocheng
Yang, Jian
author_sort Zhang, Lei
collection PubMed
description BACKGROUND: The subarachnoid space width (SASw) is part of crucial neuroimaging criteria for the diagnosis of subarachnoid space enlargement in infants. In addition to indicating the presence of these diseases, SASw can be used to assess their severity. Therefore, it is important to be able to measure the SASw accurately. AIM: This study aimed to compare the accuracy of measurements made from axial and coronal T2-weighted imaging (T2WI) and to establish a consentaneous measurement scheme of SASw in infants. METHODS: A total of 63 infants (31 males and 32 females) aged 4 days to 24 months were enrolled in this study. The supratentorial subarachnoid space volume (SASv) and corrected SASv (cSASv) were used as the gold standard reference. The SASw (including interhemispheric width and bilateral frontal craniocortical width) was measured on axial and coronal T2WI. The intra- and inter-observer reproducibility and agreement of the SASw were assessed by the intraclass correlation coefficient (ICC) and Bland–Altman analysis. A paired t-test was used to compare SASw measured on axial and coronal images. The accuracy of SASw measurements made from axial and coronal T2WI was evaluated by the relationships between the SASw and supratentorial SASv and between the SASw and supratentorial cSASv, and the relationships were examined by multivariate linear regression. RESULTS: The intra- and inter-observer ICC values of the three SASw measurements were greater on coronal T2WI than on axial T2WI. Bland–Altman analysis confirmed that the SASw values measured on coronal T2WI had better intra- and inter-observer agreement than axial T2WI. According to the multivariate linear regression results, model 4 (the SASw measured in coronal T2WI) was the best predictor of supratentorial cSASv (R(2) = 0.755). CONCLUSIONS: The SASw measured on coronal T2WI was more repeatable and accurate than axial T2WI and was more representative of the actual cerebrospinal fluid accumulation in the supratentorial subarachnoid space. RELEVANCE FOR PATIENTS: The SASw has been found to be a simple and essential substitution for supratentorial SASv, which can be measured on both axial T2WI passing through the bodies of the bilateral ventricles and coronal T2WI at the level of the foramen of Monro. The SASw measured on coronal T2WI was more beneficial to the diagnosis and severity assessment of subarachnoid space enlargement in infants.
format Online
Article
Text
id pubmed-9741930
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Whioce Publishing Pte. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-97419302022-12-13 Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study Zhang, Lei Liu, Heng Ren, Zhuanqin Wang, Xiaohu Meng, Xiaoli Wei, Xiaocheng Yang, Jian J Clin Transl Res Original Article BACKGROUND: The subarachnoid space width (SASw) is part of crucial neuroimaging criteria for the diagnosis of subarachnoid space enlargement in infants. In addition to indicating the presence of these diseases, SASw can be used to assess their severity. Therefore, it is important to be able to measure the SASw accurately. AIM: This study aimed to compare the accuracy of measurements made from axial and coronal T2-weighted imaging (T2WI) and to establish a consentaneous measurement scheme of SASw in infants. METHODS: A total of 63 infants (31 males and 32 females) aged 4 days to 24 months were enrolled in this study. The supratentorial subarachnoid space volume (SASv) and corrected SASv (cSASv) were used as the gold standard reference. The SASw (including interhemispheric width and bilateral frontal craniocortical width) was measured on axial and coronal T2WI. The intra- and inter-observer reproducibility and agreement of the SASw were assessed by the intraclass correlation coefficient (ICC) and Bland–Altman analysis. A paired t-test was used to compare SASw measured on axial and coronal images. The accuracy of SASw measurements made from axial and coronal T2WI was evaluated by the relationships between the SASw and supratentorial SASv and between the SASw and supratentorial cSASv, and the relationships were examined by multivariate linear regression. RESULTS: The intra- and inter-observer ICC values of the three SASw measurements were greater on coronal T2WI than on axial T2WI. Bland–Altman analysis confirmed that the SASw values measured on coronal T2WI had better intra- and inter-observer agreement than axial T2WI. According to the multivariate linear regression results, model 4 (the SASw measured in coronal T2WI) was the best predictor of supratentorial cSASv (R(2) = 0.755). CONCLUSIONS: The SASw measured on coronal T2WI was more repeatable and accurate than axial T2WI and was more representative of the actual cerebrospinal fluid accumulation in the supratentorial subarachnoid space. RELEVANCE FOR PATIENTS: The SASw has been found to be a simple and essential substitution for supratentorial SASv, which can be measured on both axial T2WI passing through the bodies of the bilateral ventricles and coronal T2WI at the level of the foramen of Monro. The SASw measured on coronal T2WI was more beneficial to the diagnosis and severity assessment of subarachnoid space enlargement in infants. Whioce Publishing Pte. Ltd. 2022-11-15 /pmc/articles/PMC9741930/ /pubmed/36518203 Text en Copyright: © 2022 Author(s). https://creativecommons.org/licenses/by-nc/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License, permitting all noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Zhang, Lei
Liu, Heng
Ren, Zhuanqin
Wang, Xiaohu
Meng, Xiaoli
Wei, Xiaocheng
Yang, Jian
Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
title Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
title_full Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
title_fullStr Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
title_full_unstemmed Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
title_short Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
title_sort coronal t2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: a descriptive study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741930/
https://www.ncbi.nlm.nih.gov/pubmed/36518203
work_keys_str_mv AT zhanglei coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy
AT liuheng coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy
AT renzhuanqin coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy
AT wangxiaohu coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy
AT mengxiaoli coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy
AT weixiaocheng coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy
AT yangjian coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy