Cargando…
Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study
BACKGROUND: The subarachnoid space width (SASw) is part of crucial neuroimaging criteria for the diagnosis of subarachnoid space enlargement in infants. In addition to indicating the presence of these diseases, SASw can be used to assess their severity. Therefore, it is important to be able to measu...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Whioce Publishing Pte. Ltd.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741930/ https://www.ncbi.nlm.nih.gov/pubmed/36518203 |
_version_ | 1784848421923848192 |
---|---|
author | Zhang, Lei Liu, Heng Ren, Zhuanqin Wang, Xiaohu Meng, Xiaoli Wei, Xiaocheng Yang, Jian |
author_facet | Zhang, Lei Liu, Heng Ren, Zhuanqin Wang, Xiaohu Meng, Xiaoli Wei, Xiaocheng Yang, Jian |
author_sort | Zhang, Lei |
collection | PubMed |
description | BACKGROUND: The subarachnoid space width (SASw) is part of crucial neuroimaging criteria for the diagnosis of subarachnoid space enlargement in infants. In addition to indicating the presence of these diseases, SASw can be used to assess their severity. Therefore, it is important to be able to measure the SASw accurately. AIM: This study aimed to compare the accuracy of measurements made from axial and coronal T2-weighted imaging (T2WI) and to establish a consentaneous measurement scheme of SASw in infants. METHODS: A total of 63 infants (31 males and 32 females) aged 4 days to 24 months were enrolled in this study. The supratentorial subarachnoid space volume (SASv) and corrected SASv (cSASv) were used as the gold standard reference. The SASw (including interhemispheric width and bilateral frontal craniocortical width) was measured on axial and coronal T2WI. The intra- and inter-observer reproducibility and agreement of the SASw were assessed by the intraclass correlation coefficient (ICC) and Bland–Altman analysis. A paired t-test was used to compare SASw measured on axial and coronal images. The accuracy of SASw measurements made from axial and coronal T2WI was evaluated by the relationships between the SASw and supratentorial SASv and between the SASw and supratentorial cSASv, and the relationships were examined by multivariate linear regression. RESULTS: The intra- and inter-observer ICC values of the three SASw measurements were greater on coronal T2WI than on axial T2WI. Bland–Altman analysis confirmed that the SASw values measured on coronal T2WI had better intra- and inter-observer agreement than axial T2WI. According to the multivariate linear regression results, model 4 (the SASw measured in coronal T2WI) was the best predictor of supratentorial cSASv (R(2) = 0.755). CONCLUSIONS: The SASw measured on coronal T2WI was more repeatable and accurate than axial T2WI and was more representative of the actual cerebrospinal fluid accumulation in the supratentorial subarachnoid space. RELEVANCE FOR PATIENTS: The SASw has been found to be a simple and essential substitution for supratentorial SASv, which can be measured on both axial T2WI passing through the bodies of the bilateral ventricles and coronal T2WI at the level of the foramen of Monro. The SASw measured on coronal T2WI was more beneficial to the diagnosis and severity assessment of subarachnoid space enlargement in infants. |
format | Online Article Text |
id | pubmed-9741930 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Whioce Publishing Pte. Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-97419302022-12-13 Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study Zhang, Lei Liu, Heng Ren, Zhuanqin Wang, Xiaohu Meng, Xiaoli Wei, Xiaocheng Yang, Jian J Clin Transl Res Original Article BACKGROUND: The subarachnoid space width (SASw) is part of crucial neuroimaging criteria for the diagnosis of subarachnoid space enlargement in infants. In addition to indicating the presence of these diseases, SASw can be used to assess their severity. Therefore, it is important to be able to measure the SASw accurately. AIM: This study aimed to compare the accuracy of measurements made from axial and coronal T2-weighted imaging (T2WI) and to establish a consentaneous measurement scheme of SASw in infants. METHODS: A total of 63 infants (31 males and 32 females) aged 4 days to 24 months were enrolled in this study. The supratentorial subarachnoid space volume (SASv) and corrected SASv (cSASv) were used as the gold standard reference. The SASw (including interhemispheric width and bilateral frontal craniocortical width) was measured on axial and coronal T2WI. The intra- and inter-observer reproducibility and agreement of the SASw were assessed by the intraclass correlation coefficient (ICC) and Bland–Altman analysis. A paired t-test was used to compare SASw measured on axial and coronal images. The accuracy of SASw measurements made from axial and coronal T2WI was evaluated by the relationships between the SASw and supratentorial SASv and between the SASw and supratentorial cSASv, and the relationships were examined by multivariate linear regression. RESULTS: The intra- and inter-observer ICC values of the three SASw measurements were greater on coronal T2WI than on axial T2WI. Bland–Altman analysis confirmed that the SASw values measured on coronal T2WI had better intra- and inter-observer agreement than axial T2WI. According to the multivariate linear regression results, model 4 (the SASw measured in coronal T2WI) was the best predictor of supratentorial cSASv (R(2) = 0.755). CONCLUSIONS: The SASw measured on coronal T2WI was more repeatable and accurate than axial T2WI and was more representative of the actual cerebrospinal fluid accumulation in the supratentorial subarachnoid space. RELEVANCE FOR PATIENTS: The SASw has been found to be a simple and essential substitution for supratentorial SASv, which can be measured on both axial T2WI passing through the bodies of the bilateral ventricles and coronal T2WI at the level of the foramen of Monro. The SASw measured on coronal T2WI was more beneficial to the diagnosis and severity assessment of subarachnoid space enlargement in infants. Whioce Publishing Pte. Ltd. 2022-11-15 /pmc/articles/PMC9741930/ /pubmed/36518203 Text en Copyright: © 2022 Author(s). https://creativecommons.org/licenses/by-nc/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License, permitting all noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Zhang, Lei Liu, Heng Ren, Zhuanqin Wang, Xiaohu Meng, Xiaoli Wei, Xiaocheng Yang, Jian Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study |
title | Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study |
title_full | Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study |
title_fullStr | Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study |
title_full_unstemmed | Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study |
title_short | Coronal T2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: A descriptive study |
title_sort | coronal t2-weighted imaging improves the measurement accuracy of the subarachnoid space in infants: a descriptive study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9741930/ https://www.ncbi.nlm.nih.gov/pubmed/36518203 |
work_keys_str_mv | AT zhanglei coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy AT liuheng coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy AT renzhuanqin coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy AT wangxiaohu coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy AT mengxiaoli coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy AT weixiaocheng coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy AT yangjian coronalt2weightedimagingimprovesthemeasurementaccuracyofthesubarachnoidspaceininfantsadescriptivestudy |