Cargando…

Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force

Objective: In attempts to improve the quality of life of women, continuous projects are sought between rehabilitation intervention and engineering. Using the knowledge of the pelvic floor muscle (PFM) physiology, assessment and training methods are developed to reduce lower urinary tract symptoms su...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9744264/
https://www.ncbi.nlm.nih.gov/pubmed/36518785
http://dx.doi.org/10.1109/JTEHM.2022.3223258
_version_ 1784848884241006592
collection PubMed
description Objective: In attempts to improve the quality of life of women, continuous projects are sought between rehabilitation intervention and engineering. Using the knowledge of the pelvic floor muscle (PFM) physiology, assessment and training methods are developed to reduce lower urinary tract symptoms such as urinary incontinence. Therefore, this paper covers the design and implementation of a portable vaginal dynamometer. Methods: A PFM probe is designed, 3D printed, assembled, and tested in ten women to assess its acceptability and usability. The feedback from the usability study is used to optimize the PFM probe design. A vaginal dynamometer is developed based on the designed PFM probe, then tested for linearity, repeatability, hysteresis, noise and heat effect, and power consumption. The variability between the different produced PFM probe prototypes is evaluated. Results: Force measurements are made using a load cell. Wireless communication is performed through a Bluetooth low energy transceiver v5.0, with a corresponding interface on both computer and smartphone. The device operates at a 3.3V supply and achieves a power consumption of 49.5 mW in operating mode. Two PFM probe sizes are designed to accommodate different vaginal hiatus sizes, based on usability study feedback. The proposed system allows the physiotherapist to wirelessly monitor variation in pelvic floor muscle force during assessment and/or training. Discussion/Conclusion: The testing results showed that the newly designed system has the potential to measure the PFM function in functional conditions such as the standing position.
format Online
Article
Text
id pubmed-9744264
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-97442642022-12-13 Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force IEEE J Transl Eng Health Med Article Objective: In attempts to improve the quality of life of women, continuous projects are sought between rehabilitation intervention and engineering. Using the knowledge of the pelvic floor muscle (PFM) physiology, assessment and training methods are developed to reduce lower urinary tract symptoms such as urinary incontinence. Therefore, this paper covers the design and implementation of a portable vaginal dynamometer. Methods: A PFM probe is designed, 3D printed, assembled, and tested in ten women to assess its acceptability and usability. The feedback from the usability study is used to optimize the PFM probe design. A vaginal dynamometer is developed based on the designed PFM probe, then tested for linearity, repeatability, hysteresis, noise and heat effect, and power consumption. The variability between the different produced PFM probe prototypes is evaluated. Results: Force measurements are made using a load cell. Wireless communication is performed through a Bluetooth low energy transceiver v5.0, with a corresponding interface on both computer and smartphone. The device operates at a 3.3V supply and achieves a power consumption of 49.5 mW in operating mode. Two PFM probe sizes are designed to accommodate different vaginal hiatus sizes, based on usability study feedback. The proposed system allows the physiotherapist to wirelessly monitor variation in pelvic floor muscle force during assessment and/or training. Discussion/Conclusion: The testing results showed that the newly designed system has the potential to measure the PFM function in functional conditions such as the standing position. IEEE 2022-11-18 /pmc/articles/PMC9744264/ /pubmed/36518785 http://dx.doi.org/10.1109/JTEHM.2022.3223258 Text en https://creativecommons.org/licenses/by/4.0/This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force
title Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force
title_full Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force
title_fullStr Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force
title_full_unstemmed Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force
title_short Portable Dynamometer-Based Measurement of Pelvic Floor Muscle Force
title_sort portable dynamometer-based measurement of pelvic floor muscle force
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9744264/
https://www.ncbi.nlm.nih.gov/pubmed/36518785
http://dx.doi.org/10.1109/JTEHM.2022.3223258
work_keys_str_mv AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce
AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce
AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce
AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce
AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce
AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce
AT portabledynamometerbasedmeasurementofpelvicfloormuscleforce