Cargando…

Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?

Background: A volar or reverse Barton fracture refers to an intra-articular distal radius fracture that extends out to the volar aspect of the distal radius and there may be subluxation or dislocation in that direction. The overall goal of managing volar Barton fractures is to obtain motion that is...

Descripción completa

Detalles Bibliográficos
Autores principales: S J, Karthik, Ethiraj, Prabhu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9745101/
https://www.ncbi.nlm.nih.gov/pubmed/36523730
http://dx.doi.org/10.7759/cureus.31427
_version_ 1784849070850834432
author S J, Karthik
Ethiraj, Prabhu
author_facet S J, Karthik
Ethiraj, Prabhu
author_sort S J, Karthik
collection PubMed
description Background: A volar or reverse Barton fracture refers to an intra-articular distal radius fracture that extends out to the volar aspect of the distal radius and there may be subluxation or dislocation in that direction. The overall goal of managing volar Barton fractures is to obtain motion that is pain-free, allow the patient to return to their usual activities, and minimize the risk of development of early-onset arthritis which may cause disability. Though various management options are available, this study deals with the assessment of functional and radiological outcomes of volar Barton fracture fixed with a variable locking plate. Material and methods: A prospective, observational, and hospital-based study was conducted at R. L. Jalappa Hospital and Research Centre, Sri Devaraj Urs Medical College (SDUMC), Tamaka, India, on patients with volar Barton fracture managed with a variable locking plate from the period December 2019 to June 2021. Clinical data were assessed with Disabilities of Arm, Shoulder and Hand (DASH) score, Gartland and Werley demerit criteria, and Sarmiento modification of Lindstrom criteria.  Results: Forty subjects with a mean age of 36.43 ± 10.59 years were included in the study. The mean flexion, extension, supination, and pronation were 70.63° ± 3.6°, 74.3° ± 3.64°, 79.83° ± 2.67°, and 76.28° ± 1.99° degrees respectively at the end of six months. Based on Gartland and Werley's outcome, the majority (65%) of the study population was found to have an excellent outcome, 30% had a good outcome and only 5% had a fair outcome. The mean DASH score was 13.98 ± 5.76. According to Sarmiento's modification of Lindstrom criteria, 22 patients had good radiological outcomes, 11 had excellent outcomes and seven had fair outcomes. Conclusion: The study concludes that fixation of volar Barton fractures with variable locking plates has a better role in immediate stability, maintaining anatomic reduction, and early mobilization. It also provides better functional outcomes and a good anatomical reduction. 
format Online
Article
Text
id pubmed-9745101
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-97451012022-12-14 Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures? S J, Karthik Ethiraj, Prabhu Cureus Orthopedics Background: A volar or reverse Barton fracture refers to an intra-articular distal radius fracture that extends out to the volar aspect of the distal radius and there may be subluxation or dislocation in that direction. The overall goal of managing volar Barton fractures is to obtain motion that is pain-free, allow the patient to return to their usual activities, and minimize the risk of development of early-onset arthritis which may cause disability. Though various management options are available, this study deals with the assessment of functional and radiological outcomes of volar Barton fracture fixed with a variable locking plate. Material and methods: A prospective, observational, and hospital-based study was conducted at R. L. Jalappa Hospital and Research Centre, Sri Devaraj Urs Medical College (SDUMC), Tamaka, India, on patients with volar Barton fracture managed with a variable locking plate from the period December 2019 to June 2021. Clinical data were assessed with Disabilities of Arm, Shoulder and Hand (DASH) score, Gartland and Werley demerit criteria, and Sarmiento modification of Lindstrom criteria.  Results: Forty subjects with a mean age of 36.43 ± 10.59 years were included in the study. The mean flexion, extension, supination, and pronation were 70.63° ± 3.6°, 74.3° ± 3.64°, 79.83° ± 2.67°, and 76.28° ± 1.99° degrees respectively at the end of six months. Based on Gartland and Werley's outcome, the majority (65%) of the study population was found to have an excellent outcome, 30% had a good outcome and only 5% had a fair outcome. The mean DASH score was 13.98 ± 5.76. According to Sarmiento's modification of Lindstrom criteria, 22 patients had good radiological outcomes, 11 had excellent outcomes and seven had fair outcomes. Conclusion: The study concludes that fixation of volar Barton fractures with variable locking plates has a better role in immediate stability, maintaining anatomic reduction, and early mobilization. It also provides better functional outcomes and a good anatomical reduction.  Cureus 2022-11-12 /pmc/articles/PMC9745101/ /pubmed/36523730 http://dx.doi.org/10.7759/cureus.31427 Text en Copyright © 2022, S J et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
S J, Karthik
Ethiraj, Prabhu
Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?
title Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?
title_full Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?
title_fullStr Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?
title_full_unstemmed Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?
title_short Do Variable Locking Plates Provide Better Functional and Radiological Outcomes in Volar Barton Fractures?
title_sort do variable locking plates provide better functional and radiological outcomes in volar barton fractures?
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9745101/
https://www.ncbi.nlm.nih.gov/pubmed/36523730
http://dx.doi.org/10.7759/cureus.31427
work_keys_str_mv AT sjkarthik dovariablelockingplatesprovidebetterfunctionalandradiologicaloutcomesinvolarbartonfractures
AT ethirajprabhu dovariablelockingplatesprovidebetterfunctionalandradiologicaloutcomesinvolarbartonfractures