Cargando…
Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear
Endovascular repair of popliteal artery aneurysms (PAA) using a stent graft is suitable for patients with favorable anatomy. In the domestic situation where Gore Medical withdrew, we report two cases of unusual complications of pseudoaneurysm after endovascular repair of PAA. A 44-year-old male with...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Vascular Surgery
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9745565/ https://www.ncbi.nlm.nih.gov/pubmed/36510690 http://dx.doi.org/10.5758/vsi.220035 |
_version_ | 1784849181014228992 |
---|---|
author | Kim, Min-Kyu Kim, Jun-Gon Kim, Cho-Shin Park, Kwang-Bo Yang, Shin-Seok Park, Yang-Jin |
author_facet | Kim, Min-Kyu Kim, Jun-Gon Kim, Cho-Shin Park, Kwang-Bo Yang, Shin-Seok Park, Yang-Jin |
author_sort | Kim, Min-Kyu |
collection | PubMed |
description | Endovascular repair of popliteal artery aneurysms (PAA) using a stent graft is suitable for patients with favorable anatomy. In the domestic situation where Gore Medical withdrew, we report two cases of unusual complications of pseudoaneurysm after endovascular repair of PAA. A 44-year-old male with a history of bypass surgery for a PAA presented with recurrent vein graft pseudoaneurysm. Endovascular treatment using a domestic stent graft was performed. However, pseudoaneurysm developed due to the graft fabric tear 1 month later, requiring surgical removal. In another case, an 84-year-old female presented with acute limb ischemia related to PAA. Endovascular aneurysm repair with the same domestic stent graft was performed. However, stent graft failure occurred 2 years later and the patient underwent open surgical repair. There was a graft fabric disintegration. When proper endovascular device is not available, open surgical treatment is the best option for treating PAA. |
format | Online Article Text |
id | pubmed-9745565 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Korean Society for Vascular Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-97455652022-12-20 Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear Kim, Min-Kyu Kim, Jun-Gon Kim, Cho-Shin Park, Kwang-Bo Yang, Shin-Seok Park, Yang-Jin Vasc Specialist Int Case Report Endovascular repair of popliteal artery aneurysms (PAA) using a stent graft is suitable for patients with favorable anatomy. In the domestic situation where Gore Medical withdrew, we report two cases of unusual complications of pseudoaneurysm after endovascular repair of PAA. A 44-year-old male with a history of bypass surgery for a PAA presented with recurrent vein graft pseudoaneurysm. Endovascular treatment using a domestic stent graft was performed. However, pseudoaneurysm developed due to the graft fabric tear 1 month later, requiring surgical removal. In another case, an 84-year-old female presented with acute limb ischemia related to PAA. Endovascular aneurysm repair with the same domestic stent graft was performed. However, stent graft failure occurred 2 years later and the patient underwent open surgical repair. There was a graft fabric disintegration. When proper endovascular device is not available, open surgical treatment is the best option for treating PAA. The Korean Society for Vascular Surgery 2022-12-13 /pmc/articles/PMC9745565/ /pubmed/36510690 http://dx.doi.org/10.5758/vsi.220035 Text en Copyright © 2022, The Korean Society for Vascular Surgery https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kim, Min-Kyu Kim, Jun-Gon Kim, Cho-Shin Park, Kwang-Bo Yang, Shin-Seok Park, Yang-Jin Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear |
title | Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear |
title_full | Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear |
title_fullStr | Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear |
title_full_unstemmed | Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear |
title_short | Repeated Pseudoaneurysm after Endovascular Repair of Popliteal Aneurysm due to Graft Disintegration and Fabric Tear |
title_sort | repeated pseudoaneurysm after endovascular repair of popliteal aneurysm due to graft disintegration and fabric tear |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9745565/ https://www.ncbi.nlm.nih.gov/pubmed/36510690 http://dx.doi.org/10.5758/vsi.220035 |
work_keys_str_mv | AT kimminkyu repeatedpseudoaneurysmafterendovascularrepairofpoplitealaneurysmduetograftdisintegrationandfabrictear AT kimjungon repeatedpseudoaneurysmafterendovascularrepairofpoplitealaneurysmduetograftdisintegrationandfabrictear AT kimchoshin repeatedpseudoaneurysmafterendovascularrepairofpoplitealaneurysmduetograftdisintegrationandfabrictear AT parkkwangbo repeatedpseudoaneurysmafterendovascularrepairofpoplitealaneurysmduetograftdisintegrationandfabrictear AT yangshinseok repeatedpseudoaneurysmafterendovascularrepairofpoplitealaneurysmduetograftdisintegrationandfabrictear AT parkyangjin repeatedpseudoaneurysmafterendovascularrepairofpoplitealaneurysmduetograftdisintegrationandfabrictear |