Cargando…
Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
BACKGROUND: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung d...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9746649/ https://www.ncbi.nlm.nih.gov/pubmed/36523810 http://dx.doi.org/10.5603/RPOR.a2022.0103 |
_version_ | 1784849411889692672 |
---|---|
author | Abdollahi, Sara Yazdi, Mohammad Hadi Hadizadeh Mowlavi, Ali Asghar Ceberg, Sofie Aznar, Marianne Camille Tabrizi, Fatemeh Varshoee Salek, Roham Ghodsi, Alireza Jamali, Farideh |
author_facet | Abdollahi, Sara Yazdi, Mohammad Hadi Hadizadeh Mowlavi, Ali Asghar Ceberg, Sofie Aznar, Marianne Camille Tabrizi, Fatemeh Varshoee Salek, Roham Ghodsi, Alireza Jamali, Farideh |
author_sort | Abdollahi, Sara |
collection | PubMed |
description | BACKGROUND: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. MATERIALS AND METHODS: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. RESULTS: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. CONCLUSION: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy. |
format | Online Article Text |
id | pubmed-9746649 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-97466492022-12-14 Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran Abdollahi, Sara Yazdi, Mohammad Hadi Hadizadeh Mowlavi, Ali Asghar Ceberg, Sofie Aznar, Marianne Camille Tabrizi, Fatemeh Varshoee Salek, Roham Ghodsi, Alireza Jamali, Farideh Rep Pract Oncol Radiother Research Paper BACKGROUND: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. MATERIALS AND METHODS: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. RESULTS: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. CONCLUSION: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy. Via Medica 2022-10-31 /pmc/articles/PMC9746649/ /pubmed/36523810 http://dx.doi.org/10.5603/RPOR.a2022.0103 Text en © 2022 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Research Paper Abdollahi, Sara Yazdi, Mohammad Hadi Hadizadeh Mowlavi, Ali Asghar Ceberg, Sofie Aznar, Marianne Camille Tabrizi, Fatemeh Varshoee Salek, Roham Ghodsi, Alireza Jamali, Farideh Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran |
title | Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran |
title_full | Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran |
title_fullStr | Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran |
title_full_unstemmed | Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran |
title_short | Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran |
title_sort | surface guided 3dcrt in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in iran |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9746649/ https://www.ncbi.nlm.nih.gov/pubmed/36523810 http://dx.doi.org/10.5603/RPOR.a2022.0103 |
work_keys_str_mv | AT abdollahisara surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT yazdimohammadhadihadizadeh surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT mowlavialiasghar surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT cebergsofie surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT aznarmariannecamille surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT tabrizifatemehvarshoee surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT salekroham surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT ghodsialireza surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran AT jamalifarideh surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran |