Cargando…

Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran

BACKGROUND: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung d...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdollahi, Sara, Yazdi, Mohammad Hadi Hadizadeh, Mowlavi, Ali Asghar, Ceberg, Sofie, Aznar, Marianne Camille, Tabrizi, Fatemeh Varshoee, Salek, Roham, Ghodsi, Alireza, Jamali, Farideh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Via Medica 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9746649/
https://www.ncbi.nlm.nih.gov/pubmed/36523810
http://dx.doi.org/10.5603/RPOR.a2022.0103
_version_ 1784849411889692672
author Abdollahi, Sara
Yazdi, Mohammad Hadi Hadizadeh
Mowlavi, Ali Asghar
Ceberg, Sofie
Aznar, Marianne Camille
Tabrizi, Fatemeh Varshoee
Salek, Roham
Ghodsi, Alireza
Jamali, Farideh
author_facet Abdollahi, Sara
Yazdi, Mohammad Hadi Hadizadeh
Mowlavi, Ali Asghar
Ceberg, Sofie
Aznar, Marianne Camille
Tabrizi, Fatemeh Varshoee
Salek, Roham
Ghodsi, Alireza
Jamali, Farideh
author_sort Abdollahi, Sara
collection PubMed
description BACKGROUND: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. MATERIALS AND METHODS: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. RESULTS: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. CONCLUSION: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy.
format Online
Article
Text
id pubmed-9746649
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Via Medica
record_format MEDLINE/PubMed
spelling pubmed-97466492022-12-14 Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran Abdollahi, Sara Yazdi, Mohammad Hadi Hadizadeh Mowlavi, Ali Asghar Ceberg, Sofie Aznar, Marianne Camille Tabrizi, Fatemeh Varshoee Salek, Roham Ghodsi, Alireza Jamali, Farideh Rep Pract Oncol Radiother Research Paper BACKGROUND: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. MATERIALS AND METHODS: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. RESULTS: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. CONCLUSION: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy. Via Medica 2022-10-31 /pmc/articles/PMC9746649/ /pubmed/36523810 http://dx.doi.org/10.5603/RPOR.a2022.0103 Text en © 2022 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially
spellingShingle Research Paper
Abdollahi, Sara
Yazdi, Mohammad Hadi Hadizadeh
Mowlavi, Ali Asghar
Ceberg, Sofie
Aznar, Marianne Camille
Tabrizi, Fatemeh Varshoee
Salek, Roham
Ghodsi, Alireza
Jamali, Farideh
Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
title Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
title_full Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
title_fullStr Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
title_full_unstemmed Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
title_short Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in Iran
title_sort surface guided 3dcrt in deep-inspiration breath-hold for left sided breast cancer radiotherapy: implementation and first clinical experience in iran
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9746649/
https://www.ncbi.nlm.nih.gov/pubmed/36523810
http://dx.doi.org/10.5603/RPOR.a2022.0103
work_keys_str_mv AT abdollahisara surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT yazdimohammadhadihadizadeh surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT mowlavialiasghar surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT cebergsofie surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT aznarmariannecamille surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT tabrizifatemehvarshoee surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT salekroham surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT ghodsialireza surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran
AT jamalifarideh surfaceguided3dcrtindeepinspirationbreathholdforleftsidedbreastcancerradiotherapyimplementationandfirstclinicalexperienceiniran