Cargando…
Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study
INTRODUCTION: Adult spinal fusion surgery improves lumbar alignment and patient satisfaction. Adult spinal deformity surgery improves saggital balance not only lumbar lesion, but also at hip joint coverage. It was expected that hip joint coverage rate was improved and joint stress decreased. However...
Autores principales: | , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society for Spine Surgery and Related Research
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9747219/ https://www.ncbi.nlm.nih.gov/pubmed/36561150 http://dx.doi.org/10.22603/ssrr.2021-0231 |
_version_ | 1784849546550968320 |
---|---|
author | Kozaki, Takuhei Hashizume, Hiroshi Oka, Hiroyuki Ohashi, Satoru Kumano, Yoh Yamamoto, Ei Minamide, Akihito Yukawa, Yasutsugu Iwasaki, Hiroshi Tsutsui, Shunji Takami, Masanari Nakata, Keiji Taniguchi, Takaya Fukui, Daisuke Nishiyama, Daisuke Yamanaka, Manabu Tamai, Hidenobu Taiji, Ryo Murata, Shizumasa Murata, Akimasa Yamada, Hiroshi |
author_facet | Kozaki, Takuhei Hashizume, Hiroshi Oka, Hiroyuki Ohashi, Satoru Kumano, Yoh Yamamoto, Ei Minamide, Akihito Yukawa, Yasutsugu Iwasaki, Hiroshi Tsutsui, Shunji Takami, Masanari Nakata, Keiji Taniguchi, Takaya Fukui, Daisuke Nishiyama, Daisuke Yamanaka, Manabu Tamai, Hidenobu Taiji, Ryo Murata, Shizumasa Murata, Akimasa Yamada, Hiroshi |
author_sort | Kozaki, Takuhei |
collection | PubMed |
description | INTRODUCTION: Adult spinal fusion surgery improves lumbar alignment and patient satisfaction. Adult spinal deformity surgery improves saggital balance not only lumbar lesion, but also at hip joint coverage. It was expected that hip joint coverage rate was improved and joint stress decreased. However, it was reported that adjacent joint disease at hip joint was induced by adult spinal fusion surgery including sacroiliac joint fixation on an X-ray study. The mechanism is still unclear. We aimed to investigate the association between lumbosacral fusion including sacroiliac joint fixation and contact stress of the hip joint. METHODS: A 40-year-old woman with intact lumbar vertebrae underwent computed tomography. A three-dimensional nonlinear finite element model was constructed from the L4 vertebra to the femoral bone with triangular shell elements (thickness, 2 mm; size, 3 mm) for the cortical bone's outer surface and 2-mm (lumbar spine) or 3-mm (femoral bone) tetrahedral solid elements for the remaining bone. We constructed the following four models: a non-fusion model (NF), a L4-5 fusion model (L5F), a L4-S1 fusion model (S1F), and a L4-S2 alar iliac screw fixation model (S2F). A compressive load of 400 N was applied vertically to the L4 vertebra and a 10-Nm bending moment was additionally applied to the L4 vertebra to stimulate flexion, extension, left lateral bending, and axial rotation. Each model's hip joint's von Mises stress and angular motion were analyzed. RESULTS: The hip joint's angular motion in NF, L5F, S1F, and S2F gradually increased; the S2F model presented the greatest angular motion. CONCLUSIONS: The average and maximum contact stress of the hip joint was the highest in the S2F model. Thus, lumbosacral fusion surgery with sacroiliac joint fixation placed added stress on the hip joint. We propose that this was a consequence of adjacent joint spinopelvic fixation. Lumbar-to-pelvic fixation increases the angular motion and stress at the hip joint. |
format | Online Article Text |
id | pubmed-9747219 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Japanese Society for Spine Surgery and Related Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-97472192022-12-21 Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study Kozaki, Takuhei Hashizume, Hiroshi Oka, Hiroyuki Ohashi, Satoru Kumano, Yoh Yamamoto, Ei Minamide, Akihito Yukawa, Yasutsugu Iwasaki, Hiroshi Tsutsui, Shunji Takami, Masanari Nakata, Keiji Taniguchi, Takaya Fukui, Daisuke Nishiyama, Daisuke Yamanaka, Manabu Tamai, Hidenobu Taiji, Ryo Murata, Shizumasa Murata, Akimasa Yamada, Hiroshi Spine Surg Relat Res Original Article INTRODUCTION: Adult spinal fusion surgery improves lumbar alignment and patient satisfaction. Adult spinal deformity surgery improves saggital balance not only lumbar lesion, but also at hip joint coverage. It was expected that hip joint coverage rate was improved and joint stress decreased. However, it was reported that adjacent joint disease at hip joint was induced by adult spinal fusion surgery including sacroiliac joint fixation on an X-ray study. The mechanism is still unclear. We aimed to investigate the association between lumbosacral fusion including sacroiliac joint fixation and contact stress of the hip joint. METHODS: A 40-year-old woman with intact lumbar vertebrae underwent computed tomography. A three-dimensional nonlinear finite element model was constructed from the L4 vertebra to the femoral bone with triangular shell elements (thickness, 2 mm; size, 3 mm) for the cortical bone's outer surface and 2-mm (lumbar spine) or 3-mm (femoral bone) tetrahedral solid elements for the remaining bone. We constructed the following four models: a non-fusion model (NF), a L4-5 fusion model (L5F), a L4-S1 fusion model (S1F), and a L4-S2 alar iliac screw fixation model (S2F). A compressive load of 400 N was applied vertically to the L4 vertebra and a 10-Nm bending moment was additionally applied to the L4 vertebra to stimulate flexion, extension, left lateral bending, and axial rotation. Each model's hip joint's von Mises stress and angular motion were analyzed. RESULTS: The hip joint's angular motion in NF, L5F, S1F, and S2F gradually increased; the S2F model presented the greatest angular motion. CONCLUSIONS: The average and maximum contact stress of the hip joint was the highest in the S2F model. Thus, lumbosacral fusion surgery with sacroiliac joint fixation placed added stress on the hip joint. We propose that this was a consequence of adjacent joint spinopelvic fixation. Lumbar-to-pelvic fixation increases the angular motion and stress at the hip joint. The Japanese Society for Spine Surgery and Related Research 2022-04-12 /pmc/articles/PMC9747219/ /pubmed/36561150 http://dx.doi.org/10.22603/ssrr.2021-0231 Text en Copyright © 2022 The Japanese Society for Spine Surgery and Related Research https://creativecommons.org/licenses/by-nc-nd/4.0/Spine Surgery and Related Research is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Kozaki, Takuhei Hashizume, Hiroshi Oka, Hiroyuki Ohashi, Satoru Kumano, Yoh Yamamoto, Ei Minamide, Akihito Yukawa, Yasutsugu Iwasaki, Hiroshi Tsutsui, Shunji Takami, Masanari Nakata, Keiji Taniguchi, Takaya Fukui, Daisuke Nishiyama, Daisuke Yamanaka, Manabu Tamai, Hidenobu Taiji, Ryo Murata, Shizumasa Murata, Akimasa Yamada, Hiroshi Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study |
title | Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study |
title_full | Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study |
title_fullStr | Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study |
title_full_unstemmed | Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study |
title_short | Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study |
title_sort | lumbar fusion including sacroiliac joint fixation increases the stress and angular motion at the hip joint: a finite element study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9747219/ https://www.ncbi.nlm.nih.gov/pubmed/36561150 http://dx.doi.org/10.22603/ssrr.2021-0231 |
work_keys_str_mv | AT kozakitakuhei lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT hashizumehiroshi lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT okahiroyuki lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT ohashisatoru lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT kumanoyoh lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT yamamotoei lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT minamideakihito lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT yukawayasutsugu lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT iwasakihiroshi lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT tsutsuishunji lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT takamimasanari lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT nakatakeiji lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT taniguchitakaya lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT fukuidaisuke lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT nishiyamadaisuke lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT yamanakamanabu lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT tamaihidenobu lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT taijiryo lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT muratashizumasa lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT murataakimasa lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy AT yamadahiroshi lumbarfusionincludingsacroiliacjointfixationincreasesthestressandangularmotionatthehipjointafiniteelementstudy |