Cargando…

Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit

BACKGROUND: Co-circulation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other respiratory viruses, such as influenza and respiratory syncytial virus (RSV), can be a severe threat to public health. The accurate detection and differentiation of these viruses are essential for cl...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Tae Yeul, Bae, Go Eun, Kim, Ji-Youn, Kang, Minhee, Jang, Ja-Hyun, Huh, Hee Jae, Chung, Doo Ryeon, Lee, Nam Yong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750031/
https://www.ncbi.nlm.nih.gov/pubmed/36516190
http://dx.doi.org/10.1371/journal.pone.0278530
_version_ 1784850161341562880
author Kim, Tae Yeul
Bae, Go Eun
Kim, Ji-Youn
Kang, Minhee
Jang, Ja-Hyun
Huh, Hee Jae
Chung, Doo Ryeon
Lee, Nam Yong
author_facet Kim, Tae Yeul
Bae, Go Eun
Kim, Ji-Youn
Kang, Minhee
Jang, Ja-Hyun
Huh, Hee Jae
Chung, Doo Ryeon
Lee, Nam Yong
author_sort Kim, Tae Yeul
collection PubMed
description BACKGROUND: Co-circulation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other respiratory viruses, such as influenza and respiratory syncytial virus (RSV), can be a severe threat to public health. The accurate detection and differentiation of these viruses are essential for clinical laboratories. Herein, we comparatively evaluated the performance of the Kaira COVID-19/Flu/RSV Detection Kit (Kaira; Optolane, Seongnam, Korea) for detection of SARS-CoV-2, influenza A and B, and RSV in nasopharyngeal swab (NPS) specimens with that of the PowerChek SARS-CoV-2, Influenza A&B, RSV Multiplex Real-time PCR Kit (PowerChek; Kogene Biotech, Seoul, Korea). METHODS: A total of 250 archived NPS specimens collected for routine clinical testing were tested in parallel by the Kaira and PowerChek assays. RNA standards were serially diluted and tested by the Kaira assay to calculate the limit of detection (LOD). RESULTS: The positive and negative percent agreements between the Kaira and PowerChek assays were as follows: 100% (49/49) and 100% (201/201) for SARS-CoV-2; 100% (50/50) and 99.0% (198/200) for influenza A; 100% (50/50) and 100% (200/200) for influenza B; and 100% (51/51) and 100% (199/199) for RSV, respectively. The LODs of the Kaira assay for SARS-CoV-2, influenza A and B, and RSV were 106.1, 717.1, 287.3, and 442.9 copies/mL, respectively. CONCLUSIONS: The Kaira assay showed comparable performance to the PowerChek assay for detection of SARS-CoV-2, influenza A and B, and RSV in NPS specimens, indicating that the Kaira assay could be a useful diagnostic tool when these viruses are co-circulating.
format Online
Article
Text
id pubmed-9750031
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-97500312022-12-15 Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit Kim, Tae Yeul Bae, Go Eun Kim, Ji-Youn Kang, Minhee Jang, Ja-Hyun Huh, Hee Jae Chung, Doo Ryeon Lee, Nam Yong PLoS One Research Article BACKGROUND: Co-circulation of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and other respiratory viruses, such as influenza and respiratory syncytial virus (RSV), can be a severe threat to public health. The accurate detection and differentiation of these viruses are essential for clinical laboratories. Herein, we comparatively evaluated the performance of the Kaira COVID-19/Flu/RSV Detection Kit (Kaira; Optolane, Seongnam, Korea) for detection of SARS-CoV-2, influenza A and B, and RSV in nasopharyngeal swab (NPS) specimens with that of the PowerChek SARS-CoV-2, Influenza A&B, RSV Multiplex Real-time PCR Kit (PowerChek; Kogene Biotech, Seoul, Korea). METHODS: A total of 250 archived NPS specimens collected for routine clinical testing were tested in parallel by the Kaira and PowerChek assays. RNA standards were serially diluted and tested by the Kaira assay to calculate the limit of detection (LOD). RESULTS: The positive and negative percent agreements between the Kaira and PowerChek assays were as follows: 100% (49/49) and 100% (201/201) for SARS-CoV-2; 100% (50/50) and 99.0% (198/200) for influenza A; 100% (50/50) and 100% (200/200) for influenza B; and 100% (51/51) and 100% (199/199) for RSV, respectively. The LODs of the Kaira assay for SARS-CoV-2, influenza A and B, and RSV were 106.1, 717.1, 287.3, and 442.9 copies/mL, respectively. CONCLUSIONS: The Kaira assay showed comparable performance to the PowerChek assay for detection of SARS-CoV-2, influenza A and B, and RSV in NPS specimens, indicating that the Kaira assay could be a useful diagnostic tool when these viruses are co-circulating. Public Library of Science 2022-12-14 /pmc/articles/PMC9750031/ /pubmed/36516190 http://dx.doi.org/10.1371/journal.pone.0278530 Text en © 2022 Kim et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kim, Tae Yeul
Bae, Go Eun
Kim, Ji-Youn
Kang, Minhee
Jang, Ja-Hyun
Huh, Hee Jae
Chung, Doo Ryeon
Lee, Nam Yong
Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit
title Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit
title_full Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit
title_fullStr Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit
title_full_unstemmed Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit
title_short Evaluation of the Kaira COVID-19/Flu/RSV Detection Kit for detection of SARS-CoV-2, influenza A/B, and respiratory syncytial virus: A comparative study with the PowerChek SARS-CoV-2, influenza A&B, RSV Multiplex Real-time PCR Kit
title_sort evaluation of the kaira covid-19/flu/rsv detection kit for detection of sars-cov-2, influenza a/b, and respiratory syncytial virus: a comparative study with the powerchek sars-cov-2, influenza a&b, rsv multiplex real-time pcr kit
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750031/
https://www.ncbi.nlm.nih.gov/pubmed/36516190
http://dx.doi.org/10.1371/journal.pone.0278530
work_keys_str_mv AT kimtaeyeul evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT baegoeun evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT kimjiyoun evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT kangminhee evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT jangjahyun evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT huhheejae evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT chungdooryeon evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit
AT leenamyong evaluationofthekairacovid19flursvdetectionkitfordetectionofsarscov2influenzaabandrespiratorysyncytialvirusacomparativestudywiththepowercheksarscov2influenzaabrsvmultiplexrealtimepcrkit