The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sha...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750608/ https://www.ncbi.nlm.nih.gov/pubmed/36626504 http://dx.doi.org/10.1097/MD.0000000000031812 |
_version_ | 1784850292970356736 |
---|---|
author | Krisdiyanto, Bin Raja Ghazilla, Raja Ariffin Azuddin, M. Bin Ahmad Hairuddin, Muhammad Khairi Faiz Muflikhun, Muhammad Akhsin Risdiana, Nurvita Afifuddin, Eki |
author_facet | Krisdiyanto, Bin Raja Ghazilla, Raja Ariffin Azuddin, M. Bin Ahmad Hairuddin, Muhammad Khairi Faiz Muflikhun, Muhammad Akhsin Risdiana, Nurvita Afifuddin, Eki |
author_sort | Krisdiyanto, |
collection | PubMed |
description | A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel. |
format | Online Article Text |
id | pubmed-9750608 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-97506082022-12-28 The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review Krisdiyanto, Bin Raja Ghazilla, Raja Ariffin Azuddin, M. Bin Ahmad Hairuddin, Muhammad Khairi Faiz Muflikhun, Muhammad Akhsin Risdiana, Nurvita Afifuddin, Eki Medicine (Baltimore) 4200 A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel. Lippincott Williams & Wilkins 2022-12-09 /pmc/articles/PMC9750608/ /pubmed/36626504 http://dx.doi.org/10.1097/MD.0000000000031812 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | 4200 Krisdiyanto, Bin Raja Ghazilla, Raja Ariffin Azuddin, M. Bin Ahmad Hairuddin, Muhammad Khairi Faiz Muflikhun, Muhammad Akhsin Risdiana, Nurvita Afifuddin, Eki The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review |
title | The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review |
title_full | The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review |
title_fullStr | The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review |
title_full_unstemmed | The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review |
title_short | The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review |
title_sort | hypodermic syringe performance based on the iso 7886-1:2017: a narrative review |
topic | 4200 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750608/ https://www.ncbi.nlm.nih.gov/pubmed/36626504 http://dx.doi.org/10.1097/MD.0000000000031812 |
work_keys_str_mv | AT krisdiyanto thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT binrajaghazillarajaariffin thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT azuddinm thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT binahmadhairuddinmuhammadkhairifaiz thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT muflikhunmuhammadakhsin thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT risdiananurvita thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT afifuddineki thehypodermicsyringeperformancebasedontheiso788612017anarrativereview AT krisdiyanto hypodermicsyringeperformancebasedontheiso788612017anarrativereview AT binrajaghazillarajaariffin hypodermicsyringeperformancebasedontheiso788612017anarrativereview AT azuddinm hypodermicsyringeperformancebasedontheiso788612017anarrativereview AT binahmadhairuddinmuhammadkhairifaiz hypodermicsyringeperformancebasedontheiso788612017anarrativereview AT muflikhunmuhammadakhsin hypodermicsyringeperformancebasedontheiso788612017anarrativereview AT risdiananurvita hypodermicsyringeperformancebasedontheiso788612017anarrativereview AT afifuddineki hypodermicsyringeperformancebasedontheiso788612017anarrativereview |