The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review

A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sha...

Descripción completa

Detalles Bibliográficos
Autores principales: Krisdiyanto, Bin Raja Ghazilla, Raja Ariffin, Azuddin, M., Bin Ahmad Hairuddin, Muhammad Khairi Faiz, Muflikhun, Muhammad Akhsin, Risdiana, Nurvita, Afifuddin, Eki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750608/
https://www.ncbi.nlm.nih.gov/pubmed/36626504
http://dx.doi.org/10.1097/MD.0000000000031812
_version_ 1784850292970356736
author Krisdiyanto,
Bin Raja Ghazilla, Raja Ariffin
Azuddin, M.
Bin Ahmad Hairuddin, Muhammad Khairi Faiz
Muflikhun, Muhammad Akhsin
Risdiana, Nurvita
Afifuddin, Eki
author_facet Krisdiyanto,
Bin Raja Ghazilla, Raja Ariffin
Azuddin, M.
Bin Ahmad Hairuddin, Muhammad Khairi Faiz
Muflikhun, Muhammad Akhsin
Risdiana, Nurvita
Afifuddin, Eki
author_sort Krisdiyanto,
collection PubMed
description A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel.
format Online
Article
Text
id pubmed-9750608
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-97506082022-12-28 The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review Krisdiyanto, Bin Raja Ghazilla, Raja Ariffin Azuddin, M. Bin Ahmad Hairuddin, Muhammad Khairi Faiz Muflikhun, Muhammad Akhsin Risdiana, Nurvita Afifuddin, Eki Medicine (Baltimore) 4200 A syringe is used to inject fluid or medicine into the patient’s soft tissue. The main components of the syringe were the needle, barrel, and plunger. The use of syringes in the medical world is relatively high, and especially since the COVID-19 pandemic, the use of hypodermic syringes increased sharply due to vaccination. The syringe used must be effective and of good quality, so the International Organization for Standardization (ISO) has published test procedures and minimum specifications for hypodermic syringes. The performance of the syringe can be observed from the dead space, force piston operation, water and air leakage, and fitting position of the plunger in the barrel. This review shows that most researchers use the weighing method to measure the dead space, although some use other methods. The researchers found that most of the products met the minimum specifications of the ISO, and that the dimensions and shape of the syringe affected the dead space. Researchers have not examined other performance measures recommended by the ISO. Researchers have focused more on force injection than force piston operation, leakage after injection or back spray than air and water leakage, and reduction the friction of the plunger without considering the fitting position of the plunger in the barrel. Lippincott Williams & Wilkins 2022-12-09 /pmc/articles/PMC9750608/ /pubmed/36626504 http://dx.doi.org/10.1097/MD.0000000000031812 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle 4200
Krisdiyanto,
Bin Raja Ghazilla, Raja Ariffin
Azuddin, M.
Bin Ahmad Hairuddin, Muhammad Khairi Faiz
Muflikhun, Muhammad Akhsin
Risdiana, Nurvita
Afifuddin, Eki
The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
title The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
title_full The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
title_fullStr The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
title_full_unstemmed The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
title_short The hypodermic syringe performance based on the ISO 7886-1:2017: A narrative review
title_sort hypodermic syringe performance based on the iso 7886-1:2017: a narrative review
topic 4200
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9750608/
https://www.ncbi.nlm.nih.gov/pubmed/36626504
http://dx.doi.org/10.1097/MD.0000000000031812
work_keys_str_mv AT krisdiyanto thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT binrajaghazillarajaariffin thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT azuddinm thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT binahmadhairuddinmuhammadkhairifaiz thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT muflikhunmuhammadakhsin thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT risdiananurvita thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT afifuddineki thehypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT krisdiyanto hypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT binrajaghazillarajaariffin hypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT azuddinm hypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT binahmadhairuddinmuhammadkhairifaiz hypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT muflikhunmuhammadakhsin hypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT risdiananurvita hypodermicsyringeperformancebasedontheiso788612017anarrativereview
AT afifuddineki hypodermicsyringeperformancebasedontheiso788612017anarrativereview