RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards

The rapid ultrasound for shock and hypotension (RUSH) protocol is a useful tool used in the emergency department (ED) when addressing the severity and etiology of shock. It was designed to be performed in under two minutes with evaluation of the pump (heart), tank (inferior vena cava, thoracic and a...

Descripción completa

Detalles Bibliográficos
Autores principales: Rivera, Jose A, Aragon, Daniel, Thomas, Percy, Dominici, Paul, Menowsky, Michael, Akala, Olabiyi O
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9754670/
https://www.ncbi.nlm.nih.gov/pubmed/36540318
http://dx.doi.org/10.7759/cureus.32565
_version_ 1784851251152814080
author Rivera, Jose A
Aragon, Daniel
Thomas, Percy
Dominici, Paul
Menowsky, Michael
Akala, Olabiyi O
author_facet Rivera, Jose A
Aragon, Daniel
Thomas, Percy
Dominici, Paul
Menowsky, Michael
Akala, Olabiyi O
author_sort Rivera, Jose A
collection PubMed
description The rapid ultrasound for shock and hypotension (RUSH) protocol is a useful tool used in the emergency department (ED) when addressing the severity and etiology of shock. It was designed to be performed in under two minutes with evaluation of the pump (heart), tank (inferior vena cava, thoracic and abdominal compartments) and the pipes (large arteries and veins). However, its application or one similar should extend beyond the ED and into the hospital floor. Here we present an 80-year-old gentleman with a history of atrial fibrillation (A-Fib) on anticoagulation who arrived at the ED due to an episode of pre-syncope just prior to arrival. Initial EKG is concerning for A-Fib with rapid ventricular response (RVR) with a rate in the 130s. After fluid resuscitation patient improved and he was admitted to the telemetry floor for further cardiac workup and cardiology consultation. While waiting for a room in the ED, patient became hypotensive, diaphoretic and pale. After complaining of lower abdominal pain, the ED physician performed a RUSH which showed an abdominal aorta of 8 cm concerning for dissection. Diagnosis was confirmed with CT angiography of the abdomen and he was taken to the OR with successful repair of the abdominal aortic aneurysm (AAA). Patient made meaningful recovery and was discharged to in-patient rehab. The patient described in this vignette was delayed in the ED due to lack of beds on the floor. This allowed for quick ultrasound work-up by the ED physician which led to immediate recognition of the AAA and immediate response by the vascular surgery team. Should this patient have been on the hospital floor, it is unclear if such prompt steps would have occurred prior to patient’s further hemodynamic demise.
format Online
Article
Text
id pubmed-9754670
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-97546702022-12-19 RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards Rivera, Jose A Aragon, Daniel Thomas, Percy Dominici, Paul Menowsky, Michael Akala, Olabiyi O Cureus Cardiology The rapid ultrasound for shock and hypotension (RUSH) protocol is a useful tool used in the emergency department (ED) when addressing the severity and etiology of shock. It was designed to be performed in under two minutes with evaluation of the pump (heart), tank (inferior vena cava, thoracic and abdominal compartments) and the pipes (large arteries and veins). However, its application or one similar should extend beyond the ED and into the hospital floor. Here we present an 80-year-old gentleman with a history of atrial fibrillation (A-Fib) on anticoagulation who arrived at the ED due to an episode of pre-syncope just prior to arrival. Initial EKG is concerning for A-Fib with rapid ventricular response (RVR) with a rate in the 130s. After fluid resuscitation patient improved and he was admitted to the telemetry floor for further cardiac workup and cardiology consultation. While waiting for a room in the ED, patient became hypotensive, diaphoretic and pale. After complaining of lower abdominal pain, the ED physician performed a RUSH which showed an abdominal aorta of 8 cm concerning for dissection. Diagnosis was confirmed with CT angiography of the abdomen and he was taken to the OR with successful repair of the abdominal aortic aneurysm (AAA). Patient made meaningful recovery and was discharged to in-patient rehab. The patient described in this vignette was delayed in the ED due to lack of beds on the floor. This allowed for quick ultrasound work-up by the ED physician which led to immediate recognition of the AAA and immediate response by the vascular surgery team. Should this patient have been on the hospital floor, it is unclear if such prompt steps would have occurred prior to patient’s further hemodynamic demise. Cureus 2022-12-15 /pmc/articles/PMC9754670/ /pubmed/36540318 http://dx.doi.org/10.7759/cureus.32565 Text en Copyright © 2022, Rivera et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiology
Rivera, Jose A
Aragon, Daniel
Thomas, Percy
Dominici, Paul
Menowsky, Michael
Akala, Olabiyi O
RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards
title RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards
title_full RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards
title_fullStr RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards
title_full_unstemmed RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards
title_short RUSHing to the Diagnosis: Aortic Abdominal Aneurysm Detected Using the Rapid Ultrasound for Shock and Hypotension (RUSH) Protocol in the Wards
title_sort rushing to the diagnosis: aortic abdominal aneurysm detected using the rapid ultrasound for shock and hypotension (rush) protocol in the wards
topic Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9754670/
https://www.ncbi.nlm.nih.gov/pubmed/36540318
http://dx.doi.org/10.7759/cureus.32565
work_keys_str_mv AT riverajosea rushingtothediagnosisaorticabdominalaneurysmdetectedusingtherapidultrasoundforshockandhypotensionrushprotocolinthewards
AT aragondaniel rushingtothediagnosisaorticabdominalaneurysmdetectedusingtherapidultrasoundforshockandhypotensionrushprotocolinthewards
AT thomaspercy rushingtothediagnosisaorticabdominalaneurysmdetectedusingtherapidultrasoundforshockandhypotensionrushprotocolinthewards
AT dominicipaul rushingtothediagnosisaorticabdominalaneurysmdetectedusingtherapidultrasoundforshockandhypotensionrushprotocolinthewards
AT menowskymichael rushingtothediagnosisaorticabdominalaneurysmdetectedusingtherapidultrasoundforshockandhypotensionrushprotocolinthewards
AT akalaolabiyio rushingtothediagnosisaorticabdominalaneurysmdetectedusingtherapidultrasoundforshockandhypotensionrushprotocolinthewards