Cargando…

Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes

OBJECTIVES: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome. METHODS: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light...

Descripción completa

Detalles Bibliográficos
Autores principales: Almeida, Amanda Sampaio, Gripp, Flavio Mignone, Lau, Fabio, Couto, Eduardo Vieira, Chone, Carlos Takahiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756063/
https://www.ncbi.nlm.nih.gov/pubmed/34716110
http://dx.doi.org/10.1016/j.bjorl.2021.07.008
_version_ 1784851552807157760
author Almeida, Amanda Sampaio
Gripp, Flavio Mignone
Lau, Fabio
Couto, Eduardo Vieira
Chone, Carlos Takahiro
author_facet Almeida, Amanda Sampaio
Gripp, Flavio Mignone
Lau, Fabio
Couto, Eduardo Vieira
Chone, Carlos Takahiro
author_sort Almeida, Amanda Sampaio
collection PubMed
description OBJECTIVES: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome. METHODS: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light, the esophagus’s anterior wall is visualized through the tracheostomy. A tracheoesophageal fistula is made with a blade and passed through the fistula. Then a bent trocar is introduced into the lumen using the device as a guidewire. Once in the lumen, a thin guide wire is passed through up to the mouth. The voice prosthesis is positioned with retrograde insertion. Then, the patient is discharged without hospitalization. RESULTS: 15 patients submitted to this technique had a successful surgical outcome. There were no complications as pneumothorax, esophageal perforation, bleeding, or hospitalization. CONCLUSION: The new device is feasible under local anesthesia.
format Online
Article
Text
id pubmed-9756063
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97560632022-12-17 Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes Almeida, Amanda Sampaio Gripp, Flavio Mignone Lau, Fabio Couto, Eduardo Vieira Chone, Carlos Takahiro Braz J Otorhinolaryngol Original Article OBJECTIVES: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome. METHODS: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light, the esophagus’s anterior wall is visualized through the tracheostomy. A tracheoesophageal fistula is made with a blade and passed through the fistula. Then a bent trocar is introduced into the lumen using the device as a guidewire. Once in the lumen, a thin guide wire is passed through up to the mouth. The voice prosthesis is positioned with retrograde insertion. Then, the patient is discharged without hospitalization. RESULTS: 15 patients submitted to this technique had a successful surgical outcome. There were no complications as pneumothorax, esophageal perforation, bleeding, or hospitalization. CONCLUSION: The new device is feasible under local anesthesia. Elsevier 2021-10-17 /pmc/articles/PMC9756063/ /pubmed/34716110 http://dx.doi.org/10.1016/j.bjorl.2021.07.008 Text en © 2021 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Almeida, Amanda Sampaio
Gripp, Flavio Mignone
Lau, Fabio
Couto, Eduardo Vieira
Chone, Carlos Takahiro
Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
title Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
title_full Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
title_fullStr Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
title_full_unstemmed Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
title_short Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
title_sort secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756063/
https://www.ncbi.nlm.nih.gov/pubmed/34716110
http://dx.doi.org/10.1016/j.bjorl.2021.07.008
work_keys_str_mv AT almeidaamandasampaio secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes
AT grippflaviomignone secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes
AT laufabio secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes
AT coutoeduardovieira secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes
AT chonecarlostakahiro secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes