Cargando…
Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes
OBJECTIVES: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome. METHODS: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756063/ https://www.ncbi.nlm.nih.gov/pubmed/34716110 http://dx.doi.org/10.1016/j.bjorl.2021.07.008 |
_version_ | 1784851552807157760 |
---|---|
author | Almeida, Amanda Sampaio Gripp, Flavio Mignone Lau, Fabio Couto, Eduardo Vieira Chone, Carlos Takahiro |
author_facet | Almeida, Amanda Sampaio Gripp, Flavio Mignone Lau, Fabio Couto, Eduardo Vieira Chone, Carlos Takahiro |
author_sort | Almeida, Amanda Sampaio |
collection | PubMed |
description | OBJECTIVES: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome. METHODS: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light, the esophagus’s anterior wall is visualized through the tracheostomy. A tracheoesophageal fistula is made with a blade and passed through the fistula. Then a bent trocar is introduced into the lumen using the device as a guidewire. Once in the lumen, a thin guide wire is passed through up to the mouth. The voice prosthesis is positioned with retrograde insertion. Then, the patient is discharged without hospitalization. RESULTS: 15 patients submitted to this technique had a successful surgical outcome. There were no complications as pneumothorax, esophageal perforation, bleeding, or hospitalization. CONCLUSION: The new device is feasible under local anesthesia. |
format | Online Article Text |
id | pubmed-9756063 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-97560632022-12-17 Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes Almeida, Amanda Sampaio Gripp, Flavio Mignone Lau, Fabio Couto, Eduardo Vieira Chone, Carlos Takahiro Braz J Otorhinolaryngol Original Article OBJECTIVES: This study aims to describe a new secondary tracheoesophageal puncture technique with voice prosthesis insertion under local anesthesia with a low-cost device and evaluate its outcome. METHODS: With a transoral flexible transillumination device of aluminum of 2.3 mm with fiberoptic light, the esophagus’s anterior wall is visualized through the tracheostomy. A tracheoesophageal fistula is made with a blade and passed through the fistula. Then a bent trocar is introduced into the lumen using the device as a guidewire. Once in the lumen, a thin guide wire is passed through up to the mouth. The voice prosthesis is positioned with retrograde insertion. Then, the patient is discharged without hospitalization. RESULTS: 15 patients submitted to this technique had a successful surgical outcome. There were no complications as pneumothorax, esophageal perforation, bleeding, or hospitalization. CONCLUSION: The new device is feasible under local anesthesia. Elsevier 2021-10-17 /pmc/articles/PMC9756063/ /pubmed/34716110 http://dx.doi.org/10.1016/j.bjorl.2021.07.008 Text en © 2021 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article Almeida, Amanda Sampaio Gripp, Flavio Mignone Lau, Fabio Couto, Eduardo Vieira Chone, Carlos Takahiro Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
title | Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
title_full | Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
title_fullStr | Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
title_full_unstemmed | Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
title_short | Secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
title_sort | secondary tracheoesophageal puncture with a flexible transillumination device: a new technique and its outcomes |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756063/ https://www.ncbi.nlm.nih.gov/pubmed/34716110 http://dx.doi.org/10.1016/j.bjorl.2021.07.008 |
work_keys_str_mv | AT almeidaamandasampaio secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes AT grippflaviomignone secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes AT laufabio secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes AT coutoeduardovieira secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes AT chonecarlostakahiro secondarytracheoesophagealpuncturewithaflexibletransilluminationdeviceanewtechniqueanditsoutcomes |