Cargando…
Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study
BACKGROUND: The design of personal protective equipment (PPE) may affect well-being and clinical work. PPE as an integrated item may improve usability and increase adherence by healthcare professionals. Human factors design and safety may reduce occupational-acquired diseases. As an integrated PPE,...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756122/ https://www.ncbi.nlm.nih.gov/pubmed/36454625 http://dx.doi.org/10.2196/36549 |
_version_ | 1784851565986709504 |
---|---|
author | Price, Amy Lin, Ying Ling Levin, Anna S Tumietto, Fabio Almeida, Rodrigo Almeida, Ana Ciofi-Silva, Caroline Lopes Fontana, Luca Oliveira, Naila Parisi, Nicola Francesco Mainardi, Giulia Marcelino Cordeiro, Luciana Roselli, Marco Shepherd, Paul Morelli, Luana Mehrabi, Najmeh Price, Kathleen Chan, Whitney Srinivas, Shrinidhy Harrison, T Kyle Chu, May Padoveze, Maria Clara Chu, Larry |
author_facet | Price, Amy Lin, Ying Ling Levin, Anna S Tumietto, Fabio Almeida, Rodrigo Almeida, Ana Ciofi-Silva, Caroline Lopes Fontana, Luca Oliveira, Naila Parisi, Nicola Francesco Mainardi, Giulia Marcelino Cordeiro, Luciana Roselli, Marco Shepherd, Paul Morelli, Luana Mehrabi, Najmeh Price, Kathleen Chan, Whitney Srinivas, Shrinidhy Harrison, T Kyle Chu, May Padoveze, Maria Clara Chu, Larry |
author_sort | Price, Amy |
collection | PubMed |
description | BACKGROUND: The design of personal protective equipment (PPE) may affect well-being and clinical work. PPE as an integrated item may improve usability and increase adherence by healthcare professionals. Human factors design and safety may reduce occupational-acquired diseases. As an integrated PPE, a lightweight protective air-purifying respirator (L-PAPR) could be used during health procedures where healthcare professionals are exposed to airborne pathogens. The human factors affecting the implementation of alternative PPE such as L-PAPR have not been thoroughly studied. The population of interest is health care professionals, the intervention is the performance by PPE during tasks across the three PPE types 1.) N95 respirators and face shields, 2.)traditional powered air-purifying respirator(PAPR), and 3.) L-PAPR. The outcomes are user error, communications, safety, and end-user preferences. OBJECTIVE: This study will assess whether the L-PAPR improves health care professionals’ comfort in terms of perceived workload and physical and psychological burden during direct patient care when compared with the traditional PAPR or N95 and face shield. This study also aims to evaluate human factors during the comparison of the use of L-PAPR with a combination of N95 respirators plus face shields or the traditional PAPRs. METHODS: This is an interventional randomized crossover quality improvement feasibility study consisting of a 3-site simulation phase with 10 participants per site and subsequent field testing in 2 sites with 30 participants at each site. The 3 types of respiratory PPE will be compared across medical tasks and while donning and doffing. We will evaluate the user’s perceived workload, usability, usage errors, and heart rate. We will conduct semistructured interviews to identify barriers and enablers to implementation across each PPE type over a single continuous wear episode and observe interpersonal communications across conditions and PPE types. RESULTS: We expect the research may highlight communication challenges and differences in usability and convenience across PPE types along with error frequency during PPE use across PPE types, tasks, and time. CONCLUSIONS: The design of PPE may affect overall well-being and hinder or facilitate clinical work. Combining 2 pieces of PPE into a single integrated item may improve usability and reduce occupational-acquired diseases. The human factors affecting the implementation of an alternative PPE such as L-PAPR or PAPR have not been thoroughly studied. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/36549 |
format | Online Article Text |
id | pubmed-9756122 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-97561222022-12-17 Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study Price, Amy Lin, Ying Ling Levin, Anna S Tumietto, Fabio Almeida, Rodrigo Almeida, Ana Ciofi-Silva, Caroline Lopes Fontana, Luca Oliveira, Naila Parisi, Nicola Francesco Mainardi, Giulia Marcelino Cordeiro, Luciana Roselli, Marco Shepherd, Paul Morelli, Luana Mehrabi, Najmeh Price, Kathleen Chan, Whitney Srinivas, Shrinidhy Harrison, T Kyle Chu, May Padoveze, Maria Clara Chu, Larry JMIR Res Protoc Protocol BACKGROUND: The design of personal protective equipment (PPE) may affect well-being and clinical work. PPE as an integrated item may improve usability and increase adherence by healthcare professionals. Human factors design and safety may reduce occupational-acquired diseases. As an integrated PPE, a lightweight protective air-purifying respirator (L-PAPR) could be used during health procedures where healthcare professionals are exposed to airborne pathogens. The human factors affecting the implementation of alternative PPE such as L-PAPR have not been thoroughly studied. The population of interest is health care professionals, the intervention is the performance by PPE during tasks across the three PPE types 1.) N95 respirators and face shields, 2.)traditional powered air-purifying respirator(PAPR), and 3.) L-PAPR. The outcomes are user error, communications, safety, and end-user preferences. OBJECTIVE: This study will assess whether the L-PAPR improves health care professionals’ comfort in terms of perceived workload and physical and psychological burden during direct patient care when compared with the traditional PAPR or N95 and face shield. This study also aims to evaluate human factors during the comparison of the use of L-PAPR with a combination of N95 respirators plus face shields or the traditional PAPRs. METHODS: This is an interventional randomized crossover quality improvement feasibility study consisting of a 3-site simulation phase with 10 participants per site and subsequent field testing in 2 sites with 30 participants at each site. The 3 types of respiratory PPE will be compared across medical tasks and while donning and doffing. We will evaluate the user’s perceived workload, usability, usage errors, and heart rate. We will conduct semistructured interviews to identify barriers and enablers to implementation across each PPE type over a single continuous wear episode and observe interpersonal communications across conditions and PPE types. RESULTS: We expect the research may highlight communication challenges and differences in usability and convenience across PPE types along with error frequency during PPE use across PPE types, tasks, and time. CONCLUSIONS: The design of PPE may affect overall well-being and hinder or facilitate clinical work. Combining 2 pieces of PPE into a single integrated item may improve usability and reduce occupational-acquired diseases. The human factors affecting the implementation of an alternative PPE such as L-PAPR or PAPR have not been thoroughly studied. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/36549 JMIR Publications 2022-12-01 /pmc/articles/PMC9756122/ /pubmed/36454625 http://dx.doi.org/10.2196/36549 Text en ©Amy Price, Ying Ling Lin, Anna S Levin, Fabio Tumietto, Rodrigo Almeida, Ana Almeida, Caroline Lopes Ciofi-Silva, Luca Fontana, Naila Oliveira, Nicola Francesco Parisi, Giulia Marcelino Mainardi, Luciana Cordeiro, Marco Roselli, Paul Shepherd, Luana Morelli, Najmeh Mehrabi, Kathleen Price, Whitney Chan, Shrinidhy Srinivas, T Kyle Harrison, May Chu, Maria Clara Padoveze, Larry Chu. Originally published in JMIR Research Protocols (https://www.researchprotocols.org), 01.12.2022. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Research Protocols, is properly cited. The complete bibliographic information, a link to the original publication on https://www.researchprotocols.org, as well as this copyright and license information must be included. |
spellingShingle | Protocol Price, Amy Lin, Ying Ling Levin, Anna S Tumietto, Fabio Almeida, Rodrigo Almeida, Ana Ciofi-Silva, Caroline Lopes Fontana, Luca Oliveira, Naila Parisi, Nicola Francesco Mainardi, Giulia Marcelino Cordeiro, Luciana Roselli, Marco Shepherd, Paul Morelli, Luana Mehrabi, Najmeh Price, Kathleen Chan, Whitney Srinivas, Shrinidhy Harrison, T Kyle Chu, May Padoveze, Maria Clara Chu, Larry Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study |
title | Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study |
title_full | Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study |
title_fullStr | Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study |
title_full_unstemmed | Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study |
title_short | Perceived Workload Using Separate (Filtering Facepiece Respirator and Face Shield) and Powered Air-Purifying Respirator and Integrated Lightweight Protective Air-Purifying Respirator: Protocol for an International Multisite Human Factors Randomized Crossover Feasibility Study |
title_sort | perceived workload using separate (filtering facepiece respirator and face shield) and powered air-purifying respirator and integrated lightweight protective air-purifying respirator: protocol for an international multisite human factors randomized crossover feasibility study |
topic | Protocol |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756122/ https://www.ncbi.nlm.nih.gov/pubmed/36454625 http://dx.doi.org/10.2196/36549 |
work_keys_str_mv | AT priceamy perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT linyingling perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT levinannas perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT tumiettofabio perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT almeidarodrigo perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT almeidaana perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT ciofisilvacarolinelopes perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT fontanaluca perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT oliveiranaila perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT parisinicolafrancesco perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT mainardigiuliamarcelino perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT cordeiroluciana perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT rosellimarco perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT shepherdpaul perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT morelliluana perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT mehrabinajmeh perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT pricekathleen perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT chanwhitney perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT srinivasshrinidhy perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT harrisontkyle perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT chumay perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT padovezemariaclara perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy AT chularry perceivedworkloadusingseparatefilteringfacepiecerespiratorandfaceshieldandpoweredairpurifyingrespiratorandintegratedlightweightprotectiveairpurifyingrespiratorprotocolforaninternationalmultisitehumanfactorsrandomizedcrossoverfeasibilitystudy |