Cargando…
Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets
BACKGROUND: Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is a well-accepted, safe, and effective measure in the treatment of posterior capsule opacification. However, iatrogenic intraocular lens damage is a relatively common side effect that happens due to inappropriate focusing duri...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756656/ https://www.ncbi.nlm.nih.gov/pubmed/36527032 http://dx.doi.org/10.1186/s12886-022-02738-8 |
_version_ | 1784851666795757568 |
---|---|
author | Borkenstein, A. F. Borkenstein, E. M. Omidi, P. Langenbucher, A. |
author_facet | Borkenstein, A. F. Borkenstein, E. M. Omidi, P. Langenbucher, A. |
author_sort | Borkenstein, A. F. |
collection | PubMed |
description | BACKGROUND: Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is a well-accepted, safe, and effective measure in the treatment of posterior capsule opacification. However, iatrogenic intraocular lens damage is a relatively common side effect that happens due to inappropriate focusing during the procedure. This experimental study analyzes the impact of YAG-pits to obtain qualitative information. METHODS: Acrylic, monofocal hydrophilic and hydrophobic intraocular lenses (IOLs) with 6.0 mm optic and the with the same power (21D) were studied. First, all measurements were done with unmodified IOLs. Damage was intentionally created, performing YAG-pits (n = 5) in the central area of the lens optic (3.0 mm) using a photodisruption laser with the same energy level of 1.8 mJ. To simulate the cruciate pattern, the 5 defects were created in a cross shape within the 3.0 mm optical zone. Afterwards, all laboratory measurements were repeated: These included the United States Air Force (USAF) resolution test chart to study the imaging performance of the IOL, light field measurements to show the course of the rays behind the IOL and the modulation transfer function (MTF) measurements were analyzed. RESULTS: Evaluating USAF showed that unmodified lenses produced a sharper image. Damaged lenses led to a more blurred image and to the impression of a lower contrast with a kind of halo/glare effect. The light field measurement showed that YAG-pits led to a kind of dispersion and scattering effect, which was higher in hydrophobic IOLs. MTF showed a deterioration in damaged hydrophilic and hydrophobic IOLs, respectively. CONCLUSION: Our experimental study confirms that YAG-pits can reduce imaging quality of intraocular lenses. These defects behave as a new Huygens source, distribute a spherical wave that additionally illuminate the background of the USAF target. It can be assumed that material properties of the IOL (water content, refractive index) play an important role and affect results. The impact level is strongly dependent on the number, size and position of YAG-pits within the optic. Limitation: Only monofocal IOLs have been investigated so far, further tests with various IOL optics have to follow. In addition, simulating the circular pattern of YAG capsulotomy is necessary. |
format | Online Article Text |
id | pubmed-9756656 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-97566562022-12-17 Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets Borkenstein, A. F. Borkenstein, E. M. Omidi, P. Langenbucher, A. BMC Ophthalmol Research Article BACKGROUND: Neodymium:yttrium aluminum garnet (Nd:YAG) laser capsulotomy is a well-accepted, safe, and effective measure in the treatment of posterior capsule opacification. However, iatrogenic intraocular lens damage is a relatively common side effect that happens due to inappropriate focusing during the procedure. This experimental study analyzes the impact of YAG-pits to obtain qualitative information. METHODS: Acrylic, monofocal hydrophilic and hydrophobic intraocular lenses (IOLs) with 6.0 mm optic and the with the same power (21D) were studied. First, all measurements were done with unmodified IOLs. Damage was intentionally created, performing YAG-pits (n = 5) in the central area of the lens optic (3.0 mm) using a photodisruption laser with the same energy level of 1.8 mJ. To simulate the cruciate pattern, the 5 defects were created in a cross shape within the 3.0 mm optical zone. Afterwards, all laboratory measurements were repeated: These included the United States Air Force (USAF) resolution test chart to study the imaging performance of the IOL, light field measurements to show the course of the rays behind the IOL and the modulation transfer function (MTF) measurements were analyzed. RESULTS: Evaluating USAF showed that unmodified lenses produced a sharper image. Damaged lenses led to a more blurred image and to the impression of a lower contrast with a kind of halo/glare effect. The light field measurement showed that YAG-pits led to a kind of dispersion and scattering effect, which was higher in hydrophobic IOLs. MTF showed a deterioration in damaged hydrophilic and hydrophobic IOLs, respectively. CONCLUSION: Our experimental study confirms that YAG-pits can reduce imaging quality of intraocular lenses. These defects behave as a new Huygens source, distribute a spherical wave that additionally illuminate the background of the USAF target. It can be assumed that material properties of the IOL (water content, refractive index) play an important role and affect results. The impact level is strongly dependent on the number, size and position of YAG-pits within the optic. Limitation: Only monofocal IOLs have been investigated so far, further tests with various IOL optics have to follow. In addition, simulating the circular pattern of YAG capsulotomy is necessary. BioMed Central 2022-12-16 /pmc/articles/PMC9756656/ /pubmed/36527032 http://dx.doi.org/10.1186/s12886-022-02738-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Borkenstein, A. F. Borkenstein, E. M. Omidi, P. Langenbucher, A. Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets |
title | Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets |
title_full | Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets |
title_fullStr | Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets |
title_full_unstemmed | Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets |
title_short | Evaluating impact of Nd: YAG laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and USAF test targets |
title_sort | evaluating impact of nd: yag laser associated defects on optical quality of hydrophilic and hydrophobic intraocular lenses using visualization of light propagation and usaf test targets |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9756656/ https://www.ncbi.nlm.nih.gov/pubmed/36527032 http://dx.doi.org/10.1186/s12886-022-02738-8 |
work_keys_str_mv | AT borkensteinaf evaluatingimpactofndyaglaserassociateddefectsonopticalqualityofhydrophilicandhydrophobicintraocularlensesusingvisualizationoflightpropagationandusaftesttargets AT borkensteinem evaluatingimpactofndyaglaserassociateddefectsonopticalqualityofhydrophilicandhydrophobicintraocularlensesusingvisualizationoflightpropagationandusaftesttargets AT omidip evaluatingimpactofndyaglaserassociateddefectsonopticalqualityofhydrophilicandhydrophobicintraocularlensesusingvisualizationoflightpropagationandusaftesttargets AT langenbuchera evaluatingimpactofndyaglaserassociateddefectsonopticalqualityofhydrophilicandhydrophobicintraocularlensesusingvisualizationoflightpropagationandusaftesttargets |