BACKGROUND: The aim of the study was to investigate and summarize the effectiveness and safety of CT-guided microcoil localization before video-assisted thoracic surgery (VATS) for the removal of ground-glass opacity (GGO). METHODS: A total of 147 patients with GGO who were treated at our hospital b...

Descripción completa

Detalles Bibliográficos
Autores principales: An, Jianli, Dong, Yanchao, Li, Yanguo, Han, Xiaoyu, Niu, Hongtao, Zou, Zibo, Wu, Jingpeng, Tian, Ye, Chen, Zhuo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9758923/
https://www.ncbi.nlm.nih.gov/pubmed/36527097
http://dx.doi.org/10.1186/s13019-022-02048-6
_version_ 1784852142111064064
author An, Jianli
Dong, Yanchao
Li, Yanguo
Han, Xiaoyu
Niu, Hongtao
Zou, Zibo
Wu, Jingpeng
Tian, Ye
Chen, Zhuo
author_facet An, Jianli
Dong, Yanchao
Li, Yanguo
Han, Xiaoyu
Niu, Hongtao
Zou, Zibo
Wu, Jingpeng
Tian, Ye
Chen, Zhuo
author_sort An, Jianli
collection PubMed
description BACKGROUND: The aim of the study was to investigate and summarize the effectiveness and safety of CT-guided microcoil localization before video-assisted thoracic surgery (VATS) for the removal of ground-glass opacity (GGO). METHODS: A total of 147 patients with GGO who were treated at our hospital between January 2019 and February 2021 were retrospectively analyzed. They were divided into two groups according to the final position at the end of the microcoil: intracavity (n = 78) and extracavity (n = 69), which were compared based on puncture complications and influence of the coil end position on VATS. RESULTS: The proportions of supine and prone positions in the intracavity group were significantly higher than those in the extracavity group (82.1% vs. 66.7%, P < 0.05). The incidence of intrapulmonary hemorrhage, chest pain, and coil displacement in the intracavity group was significantly lower than that in the extracavity group (28.2% vs. 46.4%, 19.2% vs. 39.1%, 1.3% vs. 11.6%, P < 0.05, respectively); however, the incidence of pneumothorax was not significantly different (P > 0.05). The time of VATS and the rate of conversion to thoracotomy in the intracavity group were significantly lower than those in the extracavity group (103.4 ± 21.0 min vs. 112.2 ± 17.3 min, 0% vs. 5.8%, P < 0.05, respectively). CONCLUSION: CT-guided placement of the microcoil is a practical, simple, and convenient localization method before VATS, with a high success rate and few complications. Furthermore, it is a better alternative method to place the end of the coil in the pleural cavity because of the lower complication rate, shorter VATS time, and lower rate of thoracotomy conversion.
format Online
Article
Text
id pubmed-9758923
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-97589232022-12-18 CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study An, Jianli Dong, Yanchao Li, Yanguo Han, Xiaoyu Niu, Hongtao Zou, Zibo Wu, Jingpeng Tian, Ye Chen, Zhuo J Cardiothorac Surg Research Article BACKGROUND: The aim of the study was to investigate and summarize the effectiveness and safety of CT-guided microcoil localization before video-assisted thoracic surgery (VATS) for the removal of ground-glass opacity (GGO). METHODS: A total of 147 patients with GGO who were treated at our hospital between January 2019 and February 2021 were retrospectively analyzed. They were divided into two groups according to the final position at the end of the microcoil: intracavity (n = 78) and extracavity (n = 69), which were compared based on puncture complications and influence of the coil end position on VATS. RESULTS: The proportions of supine and prone positions in the intracavity group were significantly higher than those in the extracavity group (82.1% vs. 66.7%, P < 0.05). The incidence of intrapulmonary hemorrhage, chest pain, and coil displacement in the intracavity group was significantly lower than that in the extracavity group (28.2% vs. 46.4%, 19.2% vs. 39.1%, 1.3% vs. 11.6%, P < 0.05, respectively); however, the incidence of pneumothorax was not significantly different (P > 0.05). The time of VATS and the rate of conversion to thoracotomy in the intracavity group were significantly lower than those in the extracavity group (103.4 ± 21.0 min vs. 112.2 ± 17.3 min, 0% vs. 5.8%, P < 0.05, respectively). CONCLUSION: CT-guided placement of the microcoil is a practical, simple, and convenient localization method before VATS, with a high success rate and few complications. Furthermore, it is a better alternative method to place the end of the coil in the pleural cavity because of the lower complication rate, shorter VATS time, and lower rate of thoracotomy conversion. BioMed Central 2022-12-17 /pmc/articles/PMC9758923/ /pubmed/36527097 http://dx.doi.org/10.1186/s13019-022-02048-6 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
An, Jianli
Dong, Yanchao
Li, Yanguo
Han, Xiaoyu
Niu, Hongtao
Zou, Zibo
Wu, Jingpeng
Tian, Ye
Chen, Zhuo
CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
title CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
title_full CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
title_fullStr CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
title_full_unstemmed CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
title_short CT-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
title_sort ct-guided placement of microcoil end in the pleural cavity for video-assisted thoracic surgical resection of ground-glass opacity: a retrospective study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9758923/
https://www.ncbi.nlm.nih.gov/pubmed/36527097
http://dx.doi.org/10.1186/s13019-022-02048-6
work_keys_str_mv AT anjianli ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT dongyanchao ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT liyanguo ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT hanxiaoyu ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT niuhongtao ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT zouzibo ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT wujingpeng ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT tianye ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy
AT chenzhuo ctguidedplacementofmicrocoilendinthepleuralcavityforvideoassistedthoracicsurgicalresectionofgroundglassopacityaretrospectivestudy