Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study

BACKGROUND: Early accurate radiographic assessment of peri-implant bone condition is highly important to avoid excessive loss of supporting bone and implant failure. Cone beam computed tomography (CBCT) is the radiographic technique of choice if peri-implant dehiscence and fenestration defects are s...

Descripción completa

Detalles Bibliográficos
Autores principales: Nomier, Alaa Shafiek, Gaweesh, Yousria Salah El-Din, Taalab, Maha R., El Sadat, Shaimaa Abu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9759909/
https://www.ncbi.nlm.nih.gov/pubmed/36528573
http://dx.doi.org/10.1186/s12903-022-02663-8
_version_ 1784852337565630464
author Nomier, Alaa Shafiek
Gaweesh, Yousria Salah El-Din
Taalab, Maha R.
El Sadat, Shaimaa Abu
author_facet Nomier, Alaa Shafiek
Gaweesh, Yousria Salah El-Din
Taalab, Maha R.
El Sadat, Shaimaa Abu
author_sort Nomier, Alaa Shafiek
collection PubMed
description BACKGROUND: Early accurate radiographic assessment of peri-implant bone condition is highly important to avoid excessive loss of supporting bone and implant failure. Cone beam computed tomography (CBCT) is the radiographic technique of choice if peri-implant dehiscence and fenestration defects are suspected. The higher radiation dose and the presence of beam hardening artifacts are the main drawbacks of CBCT imaging techniques. This study aims to evaluate the influence of low-dose cone beam computed tomography (LD-CBCT) and metal artifact reduction (MAR) tool on the assessment of peri-implant dehiscence and fenestration. METHODOLOGY: Thirty titanium implants were inserted into bovine rib blocks. Twenty had standardized bone defects (10 with dehiscence and 10 with fenestration), while the remaining 10 were used as control group with no defects. Radiographic examinations held with high‐definition CBCT (HD-CBCT) and LD-CBCT with and without application of MAR tool. Images were assessed by four examiners for the presence or absence of peri-implant defects. The area under the area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, specificity, and accuracy were calculated for all radiographic protocols. RESULTS: In the absence of MAR tool, there was no difference in AUC and diagnostic values between LD-CBCT and HD-CBCT for detection of both defects. When the MAR tool was applied, the AUC values, sensitivity, and accuracy were higher in HD-CBCT than in LD-CBCT for the detection of both defects, especially for the dehiscence, while specificity remained the same. CONCLUSION: LD-CBCT can be used in the evaluation of peri-implant dehiscence and fenestration without any decrease in diagnostic accuracy. The application of MAR tool decrease the diagnostic ability of both defects, especially for the detection of dehiscence defects.
format Online
Article
Text
id pubmed-9759909
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-97599092022-12-19 Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study Nomier, Alaa Shafiek Gaweesh, Yousria Salah El-Din Taalab, Maha R. El Sadat, Shaimaa Abu BMC Oral Health Research BACKGROUND: Early accurate radiographic assessment of peri-implant bone condition is highly important to avoid excessive loss of supporting bone and implant failure. Cone beam computed tomography (CBCT) is the radiographic technique of choice if peri-implant dehiscence and fenestration defects are suspected. The higher radiation dose and the presence of beam hardening artifacts are the main drawbacks of CBCT imaging techniques. This study aims to evaluate the influence of low-dose cone beam computed tomography (LD-CBCT) and metal artifact reduction (MAR) tool on the assessment of peri-implant dehiscence and fenestration. METHODOLOGY: Thirty titanium implants were inserted into bovine rib blocks. Twenty had standardized bone defects (10 with dehiscence and 10 with fenestration), while the remaining 10 were used as control group with no defects. Radiographic examinations held with high‐definition CBCT (HD-CBCT) and LD-CBCT with and without application of MAR tool. Images were assessed by four examiners for the presence or absence of peri-implant defects. The area under the area under the receiver operating characteristic (ROC) curve (AUC), sensitivity, specificity, and accuracy were calculated for all radiographic protocols. RESULTS: In the absence of MAR tool, there was no difference in AUC and diagnostic values between LD-CBCT and HD-CBCT for detection of both defects. When the MAR tool was applied, the AUC values, sensitivity, and accuracy were higher in HD-CBCT than in LD-CBCT for the detection of both defects, especially for the dehiscence, while specificity remained the same. CONCLUSION: LD-CBCT can be used in the evaluation of peri-implant dehiscence and fenestration without any decrease in diagnostic accuracy. The application of MAR tool decrease the diagnostic ability of both defects, especially for the detection of dehiscence defects. BioMed Central 2022-12-17 /pmc/articles/PMC9759909/ /pubmed/36528573 http://dx.doi.org/10.1186/s12903-022-02663-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Nomier, Alaa Shafiek
Gaweesh, Yousria Salah El-Din
Taalab, Maha R.
El Sadat, Shaimaa Abu
Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
title Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
title_full Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
title_fullStr Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
title_full_unstemmed Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
title_short Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
title_sort efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9759909/
https://www.ncbi.nlm.nih.gov/pubmed/36528573
http://dx.doi.org/10.1186/s12903-022-02663-8
work_keys_str_mv AT nomieralaashafiek efficacyoflowdoseconebeamcomputedtomographyandmetalartifactreductiontoolforassessmentofperiimplantbonedefectsaninvitrostudy
AT gaweeshyousriasalaheldin efficacyoflowdoseconebeamcomputedtomographyandmetalartifactreductiontoolforassessmentofperiimplantbonedefectsaninvitrostudy
AT taalabmahar efficacyoflowdoseconebeamcomputedtomographyandmetalartifactreductiontoolforassessmentofperiimplantbonedefectsaninvitrostudy
AT elsadatshaimaaabu efficacyoflowdoseconebeamcomputedtomographyandmetalartifactreductiontoolforassessmentofperiimplantbonedefectsaninvitrostudy