Cargando…

Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy

PURPOSE: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. OBSERVATIONS: 8 phakic eyes und...

Descripción completa

Detalles Bibliográficos
Autores principales: Creagmile, Jack, Kim, Won I., Scouarnec, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762144/
https://www.ncbi.nlm.nih.gov/pubmed/36544749
http://dx.doi.org/10.1016/j.ajoc.2022.101749
_version_ 1784852810147299328
author Creagmile, Jack
Kim, Won I.
Scouarnec, Christian
author_facet Creagmile, Jack
Kim, Won I.
Scouarnec, Christian
author_sort Creagmile, Jack
collection PubMed
description PURPOSE: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. OBSERVATIONS: 8 phakic eyes underwent Hydrus Microstent implantation with OMNI Surgical System ab interno canaloplasty. 2 patients underwent concurrent Kahook Dual Blade goniotomy and 1 patient underwent a concurrent micropulse transscleral cyclophotocoagulation. 6 out of 8 eyes achieved successful intraocular pressure reduction. Only 1 achieved success without the need for additional medical therapy. 1 required Neodymium-doped yttrium aluminum garnet laser to clear iris obstruction of the Hydrus inlet and 1 required selective laser trabeculoplasty for additional intraocular pressure lowering. 2 out of 8 eyes required subsequent incisional glaucoma surgery for unacceptable intraocular pressure levels despite maximum tolerable medical therapy. CONCLUSIONS AND IMPORTANCE: The Hydrus Microstent combined with OMNI Surgical System ab interno canaloplasty can safely and successfully reduce intraocular pressure in phakic patients with open-angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy with a low complication rate and rapid visual recovery.
format Online
Article
Text
id pubmed-9762144
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97621442022-12-20 Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy Creagmile, Jack Kim, Won I. Scouarnec, Christian Am J Ophthalmol Case Rep Case Report PURPOSE: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. OBSERVATIONS: 8 phakic eyes underwent Hydrus Microstent implantation with OMNI Surgical System ab interno canaloplasty. 2 patients underwent concurrent Kahook Dual Blade goniotomy and 1 patient underwent a concurrent micropulse transscleral cyclophotocoagulation. 6 out of 8 eyes achieved successful intraocular pressure reduction. Only 1 achieved success without the need for additional medical therapy. 1 required Neodymium-doped yttrium aluminum garnet laser to clear iris obstruction of the Hydrus inlet and 1 required selective laser trabeculoplasty for additional intraocular pressure lowering. 2 out of 8 eyes required subsequent incisional glaucoma surgery for unacceptable intraocular pressure levels despite maximum tolerable medical therapy. CONCLUSIONS AND IMPORTANCE: The Hydrus Microstent combined with OMNI Surgical System ab interno canaloplasty can safely and successfully reduce intraocular pressure in phakic patients with open-angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy with a low complication rate and rapid visual recovery. Elsevier 2022-11-10 /pmc/articles/PMC9762144/ /pubmed/36544749 http://dx.doi.org/10.1016/j.ajoc.2022.101749 Text en © 2022 The Authors. Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Creagmile, Jack
Kim, Won I.
Scouarnec, Christian
Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
title Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
title_full Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
title_fullStr Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
title_full_unstemmed Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
title_short Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
title_sort hydrus microstent implantation with omni surgical system ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762144/
https://www.ncbi.nlm.nih.gov/pubmed/36544749
http://dx.doi.org/10.1016/j.ajoc.2022.101749
work_keys_str_mv AT creagmilejack hydrusmicrostentimplantationwithomnisurgicalsystemabinternocanaloplastyforthemanagementofopenangleglaucomainphakicpatientsrefractorytomedicaltherapy
AT kimwoni hydrusmicrostentimplantationwithomnisurgicalsystemabinternocanaloplastyforthemanagementofopenangleglaucomainphakicpatientsrefractorytomedicaltherapy
AT scouarnecchristian hydrusmicrostentimplantationwithomnisurgicalsystemabinternocanaloplastyforthemanagementofopenangleglaucomainphakicpatientsrefractorytomedicaltherapy