PURPOSE: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. OBSERVATIONS: 8 phakic eyes und...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762144/ https://www.ncbi.nlm.nih.gov/pubmed/36544749 http://dx.doi.org/10.1016/j.ajoc.2022.101749 |
_version_ | 1784852810147299328 |
---|---|
author | Creagmile, Jack Kim, Won I. Scouarnec, Christian |
author_facet | Creagmile, Jack Kim, Won I. Scouarnec, Christian |
author_sort | Creagmile, Jack |
collection | PubMed |
description | PURPOSE: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. OBSERVATIONS: 8 phakic eyes underwent Hydrus Microstent implantation with OMNI Surgical System ab interno canaloplasty. 2 patients underwent concurrent Kahook Dual Blade goniotomy and 1 patient underwent a concurrent micropulse transscleral cyclophotocoagulation. 6 out of 8 eyes achieved successful intraocular pressure reduction. Only 1 achieved success without the need for additional medical therapy. 1 required Neodymium-doped yttrium aluminum garnet laser to clear iris obstruction of the Hydrus inlet and 1 required selective laser trabeculoplasty for additional intraocular pressure lowering. 2 out of 8 eyes required subsequent incisional glaucoma surgery for unacceptable intraocular pressure levels despite maximum tolerable medical therapy. CONCLUSIONS AND IMPORTANCE: The Hydrus Microstent combined with OMNI Surgical System ab interno canaloplasty can safely and successfully reduce intraocular pressure in phakic patients with open-angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy with a low complication rate and rapid visual recovery. |
format | Online Article Text |
id | pubmed-9762144 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-97621442022-12-20 Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy Creagmile, Jack Kim, Won I. Scouarnec, Christian Am J Ophthalmol Case Rep Case Report PURPOSE: To report a series of 8 phakic eyes of 8 patients with open angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy receiving Hydrus Microstent implants combined with concomitant OMNI Surgical System ab interno canaloplasty. OBSERVATIONS: 8 phakic eyes underwent Hydrus Microstent implantation with OMNI Surgical System ab interno canaloplasty. 2 patients underwent concurrent Kahook Dual Blade goniotomy and 1 patient underwent a concurrent micropulse transscleral cyclophotocoagulation. 6 out of 8 eyes achieved successful intraocular pressure reduction. Only 1 achieved success without the need for additional medical therapy. 1 required Neodymium-doped yttrium aluminum garnet laser to clear iris obstruction of the Hydrus inlet and 1 required selective laser trabeculoplasty for additional intraocular pressure lowering. 2 out of 8 eyes required subsequent incisional glaucoma surgery for unacceptable intraocular pressure levels despite maximum tolerable medical therapy. CONCLUSIONS AND IMPORTANCE: The Hydrus Microstent combined with OMNI Surgical System ab interno canaloplasty can safely and successfully reduce intraocular pressure in phakic patients with open-angle glaucoma with uncontrolled intraocular pressure on maximum tolerable medical therapy with a low complication rate and rapid visual recovery. Elsevier 2022-11-10 /pmc/articles/PMC9762144/ /pubmed/36544749 http://dx.doi.org/10.1016/j.ajoc.2022.101749 Text en © 2022 The Authors. Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Creagmile, Jack Kim, Won I. Scouarnec, Christian Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
title | Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
title_full | Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
title_fullStr | Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
title_full_unstemmed | Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
title_short | Hydrus Microstent implantation with OMNI Surgical System Ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
title_sort | hydrus microstent implantation with omni surgical system ab interno canaloplasty for the management of open-angle glaucoma in phakic patients refractory to medical therapy |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762144/ https://www.ncbi.nlm.nih.gov/pubmed/36544749 http://dx.doi.org/10.1016/j.ajoc.2022.101749 |
work_keys_str_mv | AT creagmilejack hydrusmicrostentimplantationwithomnisurgicalsystemabinternocanaloplastyforthemanagementofopenangleglaucomainphakicpatientsrefractorytomedicaltherapy AT kimwoni hydrusmicrostentimplantationwithomnisurgicalsystemabinternocanaloplastyforthemanagementofopenangleglaucomainphakicpatientsrefractorytomedicaltherapy AT scouarnecchristian hydrusmicrostentimplantationwithomnisurgicalsystemabinternocanaloplastyforthemanagementofopenangleglaucomainphakicpatientsrefractorytomedicaltherapy |