Cargando…
Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation
PURPOSE: To determine the characteristics and cause of the increase in the amplitude of flicker electroretinography (ERG) after cataract surgery. DESIGN: Prospective, observational clinical study. PARTICIPANTS: Thirty patients who underwent cataract surgery. METHODS: Flicker ERGs were recorded with...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762194/ https://www.ncbi.nlm.nih.gov/pubmed/36545261 http://dx.doi.org/10.1016/j.xops.2022.100243 |
_version_ | 1784852819828801536 |
---|---|
author | Kato, Kumiko Nagashima, Ryunosuke Matsubara, Hisashi Ikesugi, Kengo Tsukitome, Hideyuki Matsui, Yoshitsugu Nunome, Takayasu Sugimoto, Masahiko McCulloch, Daphne L. Kondo, Mineo |
author_facet | Kato, Kumiko Nagashima, Ryunosuke Matsubara, Hisashi Ikesugi, Kengo Tsukitome, Hideyuki Matsui, Yoshitsugu Nunome, Takayasu Sugimoto, Masahiko McCulloch, Daphne L. Kondo, Mineo |
author_sort | Kato, Kumiko |
collection | PubMed |
description | PURPOSE: To determine the characteristics and cause of the increase in the amplitude of flicker electroretinography (ERG) after cataract surgery. DESIGN: Prospective, observational clinical study. PARTICIPANTS: Thirty patients who underwent cataract surgery. METHODS: Flicker ERGs were recorded with the RETeval system without mydriasis. The central macular thickness (CMT) was measured by OCT and the aqueous flare value (AFV) by laser flare-cell photometry. These examinations were performed before surgery and 1 day, 1 week, 1 month, 2 months, and 3 months after surgery. Linear regression analysis through the origin was used to compare the correlations between the relative changes in flicker ERG amplitudes and the changes in the CMT and AFV at different times after the surgery. MAIN OUTCOME MEASURES: The amplitude of flicker ERGs, CMT, and AFV. RESULTS: The mean amplitude of flicker ERGs increased significantly by 31% at 1 week after surgery (P < 0.001); a significant increase in the amplitudes was not present at 3 months after the surgery. The mean AFV was significantly increased at 1 day after surgery (P < 0.001), and the CMT was significantly increased at 1 to 3 months after surgery (P < 0.001). The changes in flicker ERG amplitudes at 1 week after surgery were significantly associated with the changes in the CMT at 1 to 3 months after surgery (P < 0.05), and they were weakly associated with the changes in AFV at 1 day after surgery (P = 0.05). CONCLUSIONS: These results suggest that the increase in the amplitude of flicker ERGs after cataract surgery is a transient phenomenon that has a peak at 1 week after surgery. The increase of flicker ERG amplitude was associated with measures that are frequently used to evaluate postoperative inflammation. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references. |
format | Online Article Text |
id | pubmed-9762194 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-97621942022-12-20 Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation Kato, Kumiko Nagashima, Ryunosuke Matsubara, Hisashi Ikesugi, Kengo Tsukitome, Hideyuki Matsui, Yoshitsugu Nunome, Takayasu Sugimoto, Masahiko McCulloch, Daphne L. Kondo, Mineo Ophthalmol Sci Original Article PURPOSE: To determine the characteristics and cause of the increase in the amplitude of flicker electroretinography (ERG) after cataract surgery. DESIGN: Prospective, observational clinical study. PARTICIPANTS: Thirty patients who underwent cataract surgery. METHODS: Flicker ERGs were recorded with the RETeval system without mydriasis. The central macular thickness (CMT) was measured by OCT and the aqueous flare value (AFV) by laser flare-cell photometry. These examinations were performed before surgery and 1 day, 1 week, 1 month, 2 months, and 3 months after surgery. Linear regression analysis through the origin was used to compare the correlations between the relative changes in flicker ERG amplitudes and the changes in the CMT and AFV at different times after the surgery. MAIN OUTCOME MEASURES: The amplitude of flicker ERGs, CMT, and AFV. RESULTS: The mean amplitude of flicker ERGs increased significantly by 31% at 1 week after surgery (P < 0.001); a significant increase in the amplitudes was not present at 3 months after the surgery. The mean AFV was significantly increased at 1 day after surgery (P < 0.001), and the CMT was significantly increased at 1 to 3 months after surgery (P < 0.001). The changes in flicker ERG amplitudes at 1 week after surgery were significantly associated with the changes in the CMT at 1 to 3 months after surgery (P < 0.05), and they were weakly associated with the changes in AFV at 1 day after surgery (P = 0.05). CONCLUSIONS: These results suggest that the increase in the amplitude of flicker ERGs after cataract surgery is a transient phenomenon that has a peak at 1 week after surgery. The increase of flicker ERG amplitude was associated with measures that are frequently used to evaluate postoperative inflammation. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references. Elsevier 2022-11-04 /pmc/articles/PMC9762194/ /pubmed/36545261 http://dx.doi.org/10.1016/j.xops.2022.100243 Text en © 2022 Published by Elsevier Inc. on behalf of American Academy of Ophthalmology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Kato, Kumiko Nagashima, Ryunosuke Matsubara, Hisashi Ikesugi, Kengo Tsukitome, Hideyuki Matsui, Yoshitsugu Nunome, Takayasu Sugimoto, Masahiko McCulloch, Daphne L. Kondo, Mineo Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation |
title | Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation |
title_full | Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation |
title_fullStr | Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation |
title_full_unstemmed | Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation |
title_short | Transient Increase of Flicker Electroretinography Amplitudes after Cataract Surgery: Association with Postoperative Inflammation |
title_sort | transient increase of flicker electroretinography amplitudes after cataract surgery: association with postoperative inflammation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762194/ https://www.ncbi.nlm.nih.gov/pubmed/36545261 http://dx.doi.org/10.1016/j.xops.2022.100243 |
work_keys_str_mv | AT katokumiko transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT nagashimaryunosuke transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT matsubarahisashi transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT ikesugikengo transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT tsukitomehideyuki transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT matsuiyoshitsugu transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT nunometakayasu transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT sugimotomasahiko transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT mccullochdaphnel transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation AT kondomineo transientincreaseofflickerelectroretinographyamplitudesaftercataractsurgeryassociationwithpostoperativeinflammation |