Cargando…

Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism

PURPOSE: To compare visual acuity and refractive results between topography-guided laser in situ keratomileusis (LASIK) planned with the Phorcides Analytic Engine (PAE) to results after wavefront-optimized (WFO) LASIK in subjects with preoperative oblique astigmatism in their manifest refraction. ME...

Descripción completa

Detalles Bibliográficos
Autores principales: Brunson, Phillip, Mann, Paul M., Mann, Paul Michael, Potvin, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762561/
https://www.ncbi.nlm.nih.gov/pubmed/36534673
http://dx.doi.org/10.1371/journal.pone.0279357
_version_ 1784852887578345472
author Brunson, Phillip
Mann, Paul M.
Mann, Paul Michael
Potvin, Richard
author_facet Brunson, Phillip
Mann, Paul M.
Mann, Paul Michael
Potvin, Richard
author_sort Brunson, Phillip
collection PubMed
description PURPOSE: To compare visual acuity and refractive results between topography-guided laser in situ keratomileusis (LASIK) planned with the Phorcides Analytic Engine (PAE) to results after wavefront-optimized (WFO) LASIK in subjects with preoperative oblique astigmatism in their manifest refraction. METHODS: This was a retrospective chart review of clinical results from eyes treated with topography-guided LASIK planned with PAE compared to eyes treated with WFO LASIK using the same Wavelight(®) excimer laser system. All included subjects had preoperative oblique astigmatism. Residual refractive error and visual acuity (uncorrected and corrected) were the measures of interest, at the visit closest to 90 days postoperative. RESULTS: A matched data set from 100 WFO and 97 PAE eyes was extracted from clinical records. At the postoperative visit the PAE group showed lower residual refractive cylinder (p = 0.04), uncorrected distance visual acuity (UDVA) (-0.06 PAE vs. -0.02 WFO, p < 0.01) and distance corrected visual acuity (CDVA) (p < 0.01). The percentage of eyes with a mean refraction spherical equivalent (MRSE) magnitude within 0.25 D and 0.50 D of plano was statistically significantly higher in the PAE group (p = 0.04 and 0.01, respectively). A statistically significantly higher percentage of eyes in the PAE group had UDVA better than or equal to -0.10 logMAR (20/16 Snellen, 36% vs 22%, p = 0.04). More eyes gained CDVA after surgery in the PAE group (53% vs 32%, p < 0.01). There were five enhancements in the WFO group versus none in the PAE group, a statistically significant difference (p = 0.03). CONCLUSIONS: Visual acuity and refractive outcomes after LASIK using PAE in eyes with oblique astigmatism in their preoperative refraction were statistically significantly better than those obtained when WFO treatment was used. The number of refractive outliers and the number of retreatments were also significantly lower with PAE treatment.
format Online
Article
Text
id pubmed-9762561
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-97625612022-12-20 Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism Brunson, Phillip Mann, Paul M. Mann, Paul Michael Potvin, Richard PLoS One Research Article PURPOSE: To compare visual acuity and refractive results between topography-guided laser in situ keratomileusis (LASIK) planned with the Phorcides Analytic Engine (PAE) to results after wavefront-optimized (WFO) LASIK in subjects with preoperative oblique astigmatism in their manifest refraction. METHODS: This was a retrospective chart review of clinical results from eyes treated with topography-guided LASIK planned with PAE compared to eyes treated with WFO LASIK using the same Wavelight(®) excimer laser system. All included subjects had preoperative oblique astigmatism. Residual refractive error and visual acuity (uncorrected and corrected) were the measures of interest, at the visit closest to 90 days postoperative. RESULTS: A matched data set from 100 WFO and 97 PAE eyes was extracted from clinical records. At the postoperative visit the PAE group showed lower residual refractive cylinder (p = 0.04), uncorrected distance visual acuity (UDVA) (-0.06 PAE vs. -0.02 WFO, p < 0.01) and distance corrected visual acuity (CDVA) (p < 0.01). The percentage of eyes with a mean refraction spherical equivalent (MRSE) magnitude within 0.25 D and 0.50 D of plano was statistically significantly higher in the PAE group (p = 0.04 and 0.01, respectively). A statistically significantly higher percentage of eyes in the PAE group had UDVA better than or equal to -0.10 logMAR (20/16 Snellen, 36% vs 22%, p = 0.04). More eyes gained CDVA after surgery in the PAE group (53% vs 32%, p < 0.01). There were five enhancements in the WFO group versus none in the PAE group, a statistically significant difference (p = 0.03). CONCLUSIONS: Visual acuity and refractive outcomes after LASIK using PAE in eyes with oblique astigmatism in their preoperative refraction were statistically significantly better than those obtained when WFO treatment was used. The number of refractive outliers and the number of retreatments were also significantly lower with PAE treatment. Public Library of Science 2022-12-19 /pmc/articles/PMC9762561/ /pubmed/36534673 http://dx.doi.org/10.1371/journal.pone.0279357 Text en © 2022 Brunson et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Brunson, Phillip
Mann, Paul M.
Mann, Paul Michael
Potvin, Richard
Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism
title Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism
title_full Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism
title_fullStr Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism
title_full_unstemmed Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism
title_short Comparison of refractive and visual acuity results after Contoura(®) Vision topography-guided LASIK planned with the Phorcides Analytic Engine to results after wavefront-optimized LASIK in eyes with oblique astigmatism
title_sort comparison of refractive and visual acuity results after contoura(®) vision topography-guided lasik planned with the phorcides analytic engine to results after wavefront-optimized lasik in eyes with oblique astigmatism
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762561/
https://www.ncbi.nlm.nih.gov/pubmed/36534673
http://dx.doi.org/10.1371/journal.pone.0279357
work_keys_str_mv AT brunsonphillip comparisonofrefractiveandvisualacuityresultsaftercontouravisiontopographyguidedlasikplannedwiththephorcidesanalyticenginetoresultsafterwavefrontoptimizedlasikineyeswithobliqueastigmatism
AT mannpaulm comparisonofrefractiveandvisualacuityresultsaftercontouravisiontopographyguidedlasikplannedwiththephorcidesanalyticenginetoresultsafterwavefrontoptimizedlasikineyeswithobliqueastigmatism
AT mannpaulmichael comparisonofrefractiveandvisualacuityresultsaftercontouravisiontopographyguidedlasikplannedwiththephorcidesanalyticenginetoresultsafterwavefrontoptimizedlasikineyeswithobliqueastigmatism
AT potvinrichard comparisonofrefractiveandvisualacuityresultsaftercontouravisiontopographyguidedlasikplannedwiththephorcidesanalyticenginetoresultsafterwavefrontoptimizedlasikineyeswithobliqueastigmatism