Cargando…

Long-Term Follow-up of a Wide-Diameter Bone-Anchored Hearing Implant: 10-Year Experience on Stability, Survival, and Tolerability of an Implant-Abutment Combination

To compare stability, survival, and soft tissue reactions between a wide-diameter (test) and previous-generation small-diameter (control) bone-anchored hearing implant and to ascertain the safety of loading the test implant 3 weeks after surgery, at a long-term follow-up of 10 years. STUDY DESIGN: T...

Descripción completa

Detalles Bibliográficos
Autores principales: Teunissen, Emma Margaretha, Caspers, Coosje Jacoba Isabella, Vijverberg, Maarten Adriaan, Mylanus, Emmanuel Antonius Maria, Hol, Myrthe Karianne Sophie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9762720/
https://www.ncbi.nlm.nih.gov/pubmed/36417764
http://dx.doi.org/10.1097/MAO.0000000000003763
Descripción
Sumario:To compare stability, survival, and soft tissue reactions between a wide-diameter (test) and previous-generation small-diameter (control) bone-anchored hearing implant and to ascertain the safety of loading the test implant 3 weeks after surgery, at a long-term follow-up of 10 years. STUDY DESIGN: This study is a continuation of two previously completed, multicenter, randomized, controlled trials and consisted of one to two additional follow-up visits until 10 years after surgery. PATIENTS: Fifty-one of the 72 participants from the previous trials were included. Patients received a test or control implant. All control implants were loaded 6 weeks after surgery (group A). Test implants were loaded 3 (group B) or 6 weeks (group C) after surgery. RESULTS: The test implant showed significantly higher implant stability quotient (ISQ) values than the control implant throughout the 10-year follow-up. At 10 years, the mean ISQ-high values for both implants were higher than at the first follow-up visit. No significant differences in change of ISQ-high from baseline to 10 years were noticed between both implants and loading groups. Soft tissue reactions were rarely seen. At 10-year follow-up, no patients presented with adverse soft tissue reactions. Excluding explantations, the implant survival rate was 78.6% (group A), 100% (group B), and 90.0% (group C). CONCLUSIONS: The test implant showed superior mean ISQ values and significantly better implant survival throughout 10-year follow-up. In addition, the current study concludes that it is safe to load the test implant at 3 weeks after surgery, as long-term results show high ISQ values and good implant survival.