Cargando…

Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool

PURPOSE: To assess the influence of defect size and tooth anatomy on the measurements performed by a 3D patient monitoring tool. METHODS: A fully dentate model was scanned to obtain a master digital file. Virtual duplicates received defects created in molars (16, 18, 28) and incisors (11, 12, 22), a...

Descripción completa

Detalles Bibliográficos
Autores principales: Gimenez-Gonzalez, Beatriz, Setyo, Christof, Picaza, Mikel Gomez, Tribst, João Paulo Mendes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9763733/
https://www.ncbi.nlm.nih.gov/pubmed/36561666
http://dx.doi.org/10.1016/j.heliyon.2022.e12103
_version_ 1784853125071372288
author Gimenez-Gonzalez, Beatriz
Setyo, Christof
Picaza, Mikel Gomez
Tribst, João Paulo Mendes
author_facet Gimenez-Gonzalez, Beatriz
Setyo, Christof
Picaza, Mikel Gomez
Tribst, João Paulo Mendes
author_sort Gimenez-Gonzalez, Beatriz
collection PubMed
description PURPOSE: To assess the influence of defect size and tooth anatomy on the measurements performed by a 3D patient monitoring tool. METHODS: A fully dentate model was scanned to obtain a master digital file. Virtual duplicates received defects created in molars (16, 18, 28) and incisors (11, 12, 22), according to different depths (60, 80, 120 microns) and sizes (small, medium, large) totaling 180 conditions. The surface changes measured by the 3D Patient Monitoring Tool (3Shape TRIOS Patient Monitoring [TPM]) were compared with the reference by 2 calibrated operators. False Positives (FP), and False Negatives (FN) defect were registered. Pearson chi-square test, Multivariate binary logistic regression and Spearman rank correlation were used to evaluate the data (α = 0.05). RESULTS: A significant association was found between the area and the presence of FP and FN (P < .01). Larger defects had higher chances to present FP or an FN respectively. There was a significant association between the tooth and the presence of a FP value (FP, P = .02; FN, P = .005) specially in molars. No significant association was found between the defect depth and the presence of a FP value. Spearman rank correlation showed a strong association between the presence of an FP and an FN (r = 0.858, P < .01). CONCLUSIONS: The defect size and tooth anatomy significantly affected the virtual follow-up, whereas defect depth did not. Small defects were correctly detected in all cases. An incorrect measurement on one side of the tooth simultaneously resulted in incorrect measurement on the opposite side. CLINICAL RELEVANCE: The clinician should be aware that different factors related to the characteristics of the defects could affect the quality of the full-arch digital follow-up. Therefore, caution is needed when interpreting the models comparison in cases that a larger area of a tooth has been modified.
format Online
Article
Text
id pubmed-9763733
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-97637332022-12-21 Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool Gimenez-Gonzalez, Beatriz Setyo, Christof Picaza, Mikel Gomez Tribst, João Paulo Mendes Heliyon Research Article PURPOSE: To assess the influence of defect size and tooth anatomy on the measurements performed by a 3D patient monitoring tool. METHODS: A fully dentate model was scanned to obtain a master digital file. Virtual duplicates received defects created in molars (16, 18, 28) and incisors (11, 12, 22), according to different depths (60, 80, 120 microns) and sizes (small, medium, large) totaling 180 conditions. The surface changes measured by the 3D Patient Monitoring Tool (3Shape TRIOS Patient Monitoring [TPM]) were compared with the reference by 2 calibrated operators. False Positives (FP), and False Negatives (FN) defect were registered. Pearson chi-square test, Multivariate binary logistic regression and Spearman rank correlation were used to evaluate the data (α = 0.05). RESULTS: A significant association was found between the area and the presence of FP and FN (P < .01). Larger defects had higher chances to present FP or an FN respectively. There was a significant association between the tooth and the presence of a FP value (FP, P = .02; FN, P = .005) specially in molars. No significant association was found between the defect depth and the presence of a FP value. Spearman rank correlation showed a strong association between the presence of an FP and an FN (r = 0.858, P < .01). CONCLUSIONS: The defect size and tooth anatomy significantly affected the virtual follow-up, whereas defect depth did not. Small defects were correctly detected in all cases. An incorrect measurement on one side of the tooth simultaneously resulted in incorrect measurement on the opposite side. CLINICAL RELEVANCE: The clinician should be aware that different factors related to the characteristics of the defects could affect the quality of the full-arch digital follow-up. Therefore, caution is needed when interpreting the models comparison in cases that a larger area of a tooth has been modified. Elsevier 2022-12-06 /pmc/articles/PMC9763733/ /pubmed/36561666 http://dx.doi.org/10.1016/j.heliyon.2022.e12103 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Gimenez-Gonzalez, Beatriz
Setyo, Christof
Picaza, Mikel Gomez
Tribst, João Paulo Mendes
Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
title Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
title_full Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
title_fullStr Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
title_full_unstemmed Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
title_short Effect of defect size and tooth anatomy in the measurements of a 3D patient monitoring tool
title_sort effect of defect size and tooth anatomy in the measurements of a 3d patient monitoring tool
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9763733/
https://www.ncbi.nlm.nih.gov/pubmed/36561666
http://dx.doi.org/10.1016/j.heliyon.2022.e12103
work_keys_str_mv AT gimenezgonzalezbeatriz effectofdefectsizeandtoothanatomyinthemeasurementsofa3dpatientmonitoringtool
AT setyochristof effectofdefectsizeandtoothanatomyinthemeasurementsofa3dpatientmonitoringtool
AT picazamikelgomez effectofdefectsizeandtoothanatomyinthemeasurementsofa3dpatientmonitoringtool
AT tribstjoaopaulomendes effectofdefectsizeandtoothanatomyinthemeasurementsofa3dpatientmonitoringtool