Cargando…

Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications

Among the five major classes of lipoprotein particles, low-density lipoprotein-cholesterol (LDL-C) is the primary lipoprotein risk factor for the development of cardiovascular diseases (CVD) through the promotion of atherosclerotic pathogenesis. Therefore, it is of paramount importance to accurately...

Descripción completa

Detalles Bibliográficos
Autores principales: Islam, S.M. Touhidul, Osa-Andrews, Bremansu, Jones, Patricia Mary, Muthukumar, Alagar R., Hashim, Ibrahim, Cao, Jing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Communications and Publications Division (CPD) of the IFCC 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9768618/
https://www.ncbi.nlm.nih.gov/pubmed/36605300
_version_ 1784854210941026304
author Islam, S.M. Touhidul
Osa-Andrews, Bremansu
Jones, Patricia Mary
Muthukumar, Alagar R.
Hashim, Ibrahim
Cao, Jing
author_facet Islam, S.M. Touhidul
Osa-Andrews, Bremansu
Jones, Patricia Mary
Muthukumar, Alagar R.
Hashim, Ibrahim
Cao, Jing
author_sort Islam, S.M. Touhidul
collection PubMed
description Among the five major classes of lipoprotein particles, low-density lipoprotein-cholesterol (LDL-C) is the primary lipoprotein risk factor for the development of cardiovascular diseases (CVD) through the promotion of atherosclerotic pathogenesis. Therefore, it is of paramount importance to accurately measure the plasma concentration of LDL-C using an appropriate method to examine the risk of CVD and determine the efficacy of therapeutic interventions to reduce the cholesterol level and examine the risk assessment strategy. At present, there is a wide variety of methods available for LDL-C measurement. In this review, we have outlined the commonly used methods of LDL-C measurement. These methods have been classified into non-automated analytical methods, calculation methods, and automated direct measurement of LDL-C. We have also described some recently proposed promising calculation methods which are being considered for clinical adoption. This current review could assist the clinicians to have a better understanding regarding the measurement techniques and comparative utilities of different methods of LDL-C measurement and guide them to select an appropriate method based on accuracy, turnaround time, and cost of test.
format Online
Article
Text
id pubmed-9768618
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Communications and Publications Division (CPD) of the IFCC
record_format MEDLINE/PubMed
spelling pubmed-97686182023-01-04 Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications Islam, S.M. Touhidul Osa-Andrews, Bremansu Jones, Patricia Mary Muthukumar, Alagar R. Hashim, Ibrahim Cao, Jing EJIFCC Review Article Among the five major classes of lipoprotein particles, low-density lipoprotein-cholesterol (LDL-C) is the primary lipoprotein risk factor for the development of cardiovascular diseases (CVD) through the promotion of atherosclerotic pathogenesis. Therefore, it is of paramount importance to accurately measure the plasma concentration of LDL-C using an appropriate method to examine the risk of CVD and determine the efficacy of therapeutic interventions to reduce the cholesterol level and examine the risk assessment strategy. At present, there is a wide variety of methods available for LDL-C measurement. In this review, we have outlined the commonly used methods of LDL-C measurement. These methods have been classified into non-automated analytical methods, calculation methods, and automated direct measurement of LDL-C. We have also described some recently proposed promising calculation methods which are being considered for clinical adoption. This current review could assist the clinicians to have a better understanding regarding the measurement techniques and comparative utilities of different methods of LDL-C measurement and guide them to select an appropriate method based on accuracy, turnaround time, and cost of test. The Communications and Publications Division (CPD) of the IFCC 2022-12-12 /pmc/articles/PMC9768618/ /pubmed/36605300 Text en Copyright © 2022 International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This is a Platinum Open Access Journal distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Islam, S.M. Touhidul
Osa-Andrews, Bremansu
Jones, Patricia Mary
Muthukumar, Alagar R.
Hashim, Ibrahim
Cao, Jing
Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications
title Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications
title_full Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications
title_fullStr Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications
title_full_unstemmed Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications
title_short Methods of Low-Density Lipoprotein-Cholesterol Measurement: Analytical and Clinical Applications
title_sort methods of low-density lipoprotein-cholesterol measurement: analytical and clinical applications
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9768618/
https://www.ncbi.nlm.nih.gov/pubmed/36605300
work_keys_str_mv AT islamsmtouhidul methodsoflowdensitylipoproteincholesterolmeasurementanalyticalandclinicalapplications
AT osaandrewsbremansu methodsoflowdensitylipoproteincholesterolmeasurementanalyticalandclinicalapplications
AT jonespatriciamary methodsoflowdensitylipoproteincholesterolmeasurementanalyticalandclinicalapplications
AT muthukumaralagarr methodsoflowdensitylipoproteincholesterolmeasurementanalyticalandclinicalapplications
AT hashimibrahim methodsoflowdensitylipoproteincholesterolmeasurementanalyticalandclinicalapplications
AT caojing methodsoflowdensitylipoproteincholesterolmeasurementanalyticalandclinicalapplications