Cargando…

Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement

The Revised Hammersmith Scale (RHS) for Spinal Muscular Atrophy (SMA) was designed as a psychometrically robust clinical outcome assessment to assess physical abilities of patients with type 2 and 3 SMA. The reliability properties of the RHS have not yet been reported. A prospective RHS reliability...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramsey, Danielle, Ramdharry, Gita, Scoto, Mariacristina, Muntoni, Francesco, Wallace, Amanda
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9770369/
https://www.ncbi.nlm.nih.gov/pubmed/36542615
http://dx.doi.org/10.1371/journal.pone.0278996
_version_ 1784854581528756224
author Ramsey, Danielle
Ramdharry, Gita
Scoto, Mariacristina
Muntoni, Francesco
Wallace, Amanda
author_facet Ramsey, Danielle
Ramdharry, Gita
Scoto, Mariacristina
Muntoni, Francesco
Wallace, Amanda
author_sort Ramsey, Danielle
collection PubMed
description The Revised Hammersmith Scale (RHS) for Spinal Muscular Atrophy (SMA) was designed as a psychometrically robust clinical outcome assessment to assess physical abilities of patients with type 2 and 3 SMA. The reliability properties of the RHS have not yet been reported. A prospective RHS reliability study was undertaken in a UK cohort of experienced neuromuscular paediatric Physiotherapists. Reliability testing was conducted via a virtual survey platform two weeks apart. Through the virtual platform participants scored videos of two RHS assessments, one of a child with SMA 2 and one of a child with SMA 3. Inter and intra-rater reliability was analysed using a type 3 Intraclass Correlation Coefficient (ICC). Intra-rater agreement was further analysed using Bland Altman (BA) Limits of Agreement (LOA) and plots. The acceptable inter and intra-rater variability was set as a change of ± 2 by the international team of expert physiotherapists who developed the RHS. Inter-rater agreement, n = 22 raters, type 3 ICC was 0.989 (95% CI 0.944 to 1.00), 97.7% of scores were within the acceptable limits of ± 2 points. Intra-rater agreement, n = 21 raters, type 3 ICC ranged from 0.922 to 1.0, with 97.6% of scores within the acceptable limits of ± 2 points. The mean SMA 2 intra-rater difference was -0.10 (-0.6 to 0.4), with lower LOA -2.24 and upper LOA +2.04. Intra-rater difference between tests for SMA 3 intra-rater difference was -0.05 (-0.6 to 0.5), with lower LOA -2.48 and upper LOA +2.38. Intra-rater scoring precision fell within BA agreement limits of ±2 points. The results demonstrate that the RHS is highly reliable when used by experienced UK physiotherapists, and variability of test scores regarding inter and intra-rater reliability was confirmed to lie within ±2 points.
format Online
Article
Text
id pubmed-9770369
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-97703692022-12-22 Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement Ramsey, Danielle Ramdharry, Gita Scoto, Mariacristina Muntoni, Francesco Wallace, Amanda PLoS One Research Article The Revised Hammersmith Scale (RHS) for Spinal Muscular Atrophy (SMA) was designed as a psychometrically robust clinical outcome assessment to assess physical abilities of patients with type 2 and 3 SMA. The reliability properties of the RHS have not yet been reported. A prospective RHS reliability study was undertaken in a UK cohort of experienced neuromuscular paediatric Physiotherapists. Reliability testing was conducted via a virtual survey platform two weeks apart. Through the virtual platform participants scored videos of two RHS assessments, one of a child with SMA 2 and one of a child with SMA 3. Inter and intra-rater reliability was analysed using a type 3 Intraclass Correlation Coefficient (ICC). Intra-rater agreement was further analysed using Bland Altman (BA) Limits of Agreement (LOA) and plots. The acceptable inter and intra-rater variability was set as a change of ± 2 by the international team of expert physiotherapists who developed the RHS. Inter-rater agreement, n = 22 raters, type 3 ICC was 0.989 (95% CI 0.944 to 1.00), 97.7% of scores were within the acceptable limits of ± 2 points. Intra-rater agreement, n = 21 raters, type 3 ICC ranged from 0.922 to 1.0, with 97.6% of scores within the acceptable limits of ± 2 points. The mean SMA 2 intra-rater difference was -0.10 (-0.6 to 0.4), with lower LOA -2.24 and upper LOA +2.04. Intra-rater difference between tests for SMA 3 intra-rater difference was -0.05 (-0.6 to 0.5), with lower LOA -2.48 and upper LOA +2.38. Intra-rater scoring precision fell within BA agreement limits of ±2 points. The results demonstrate that the RHS is highly reliable when used by experienced UK physiotherapists, and variability of test scores regarding inter and intra-rater reliability was confirmed to lie within ±2 points. Public Library of Science 2022-12-21 /pmc/articles/PMC9770369/ /pubmed/36542615 http://dx.doi.org/10.1371/journal.pone.0278996 Text en © 2022 Ramsey et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ramsey, Danielle
Ramdharry, Gita
Scoto, Mariacristina
Muntoni, Francesco
Wallace, Amanda
Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement
title Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement
title_full Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement
title_fullStr Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement
title_full_unstemmed Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement
title_short Revised Hammersmith Scale for spinal muscular atrophy: Inter and intra-rater reliability and agreement
title_sort revised hammersmith scale for spinal muscular atrophy: inter and intra-rater reliability and agreement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9770369/
https://www.ncbi.nlm.nih.gov/pubmed/36542615
http://dx.doi.org/10.1371/journal.pone.0278996
work_keys_str_mv AT ramseydanielle revisedhammersmithscaleforspinalmuscularatrophyinterandintraraterreliabilityandagreement
AT ramdharrygita revisedhammersmithscaleforspinalmuscularatrophyinterandintraraterreliabilityandagreement
AT scotomariacristina revisedhammersmithscaleforspinalmuscularatrophyinterandintraraterreliabilityandagreement
AT muntonifrancesco revisedhammersmithscaleforspinalmuscularatrophyinterandintraraterreliabilityandagreement
AT wallaceamanda revisedhammersmithscaleforspinalmuscularatrophyinterandintraraterreliabilityandagreement
AT revisedhammersmithscaleforspinalmuscularatrophyinterandintraraterreliabilityandagreement